Solution Type Technical Instruction Sure Solution 1012467.1 : Sun StorEdge[TM] 3310 SCSI Array syncs at 80 MBytes/sec on Ultra320 SCSI ports
PreviouslyPublishedAs 217179 Description The Sun StorEdge[TM] 3310 SCSI Array is capable of 160-Mbyte/second performance, but performs at only half speed (maximum throughput is 80 Mbyte/second) when it is attached to the Sun Fire[TM] V440 server's external SCSI port. Steps to Follow This issue only applies to arrays with firmware revision level 3.25Q or earlier. To check what the firmware level is do the following: ok probe-scsi-all /pci@1f,700000/scsi@2,1 Target 0 Unit 0 Disk SUN StorEdge 3310 0325<<<---(REV LEVEL) 211825920 B locks, 103430 MB OR format Searching for disks...done c2t0d0 <SUN-StorEdge3310-0325<<<-----(REV LEVEL) cyl 51713 alt 2 hd 64 sec 64> /pci@1f,700000/scsi@2,1/sd@0,0 This problem was fixed with patch ID 113722-03 which is now at 113722-12. Product Sun Fire V440 Server Sun StorageTek 3310 SCSI Array Internal Comments For Internal Sun use only. Patch 113722-03 or greater is needed to resolve BugID 4876079 V440, Sun StorEdge 3310, ULTRA320, 3310, sync Previously Published As 83326 Change History Date: 2006-01-10 User Name: 97961 Action: Approved Comment: - Converted to STM formatting for better readability - Applied trademarking - Made simple sentence/grammatical corrections Version: 5 Date: 2006-01-10 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2006-01-10 User Name: 121432 Action: Approved Comment: Checked for correctness and spelling, forwarded on for Final Review. Version: 0 Attachments This solution has no attachment |
||||||||||||
|