Solution Type Technical Instruction Sure Solution 1012329.1 : Sun StorEdge[TM] 99xx CHA port LED status indicator on DKC Panel
PreviouslyPublishedAs 217012 Description How to interpret the Channel Adapter (CHA) port Light Emitting Diode (LED) status on the DKC Panel. Steps to Follow On the DKC Panel of a Sun StorEdge[TM] 9900 or Sun StorEdge[TM] 9900V, there are two banks of Note: There are no CHA LEDs in the SE9990 DKC panel. For each bank (cluster-1 or cluster-2), the LEDs are visually divided into 3 groups. Each LED in a group represents a port on a CHA. Depending on the model, a CHA can have 4 or 8 ports. For a 4-port CHA: Upper LEDs represents ports A,B,C and D . For a 8-port CHA: Upper LEDs represents ports A,B,C and D . SE99xx CHA port status per condition of LED's: LED Condition Status of port ======================= ======================================== 1.Off - Not installed 2.Blinking Green - Installed but not connected to a server (constant speed) 3.Steady Green - Installed and connected to a server but idle 4.Flickering Green - Installed and connected - Port is busy doing I/O Product Sun StorageTek 9900V Series Array Sun StorageTek 9910 Sun StorageTek 9960 System 99xx, SE99xx, CHA, port, LED, status, indicator, DKC, Panel Previously Published As 80565 Change History Date: 2006-05-29 User Name: 111868 Action: Approved Comment: checked keywords checked TM - corrected checked expiry date checked audience publishing Version: 6 Date: 2006-05-29 User Name: 111868 Action: Accept Comment: Version: 0 Date: 2006-05-29 User Name: 90045 Action: Approved Comment: Correct! Version: 0 Date: 2006-05-11 User Name: 90045 Action: Accept Comment: Version: 0 Date: 2006-05-11 User Name: 97195 Action: Approved Comment: Pls review, the contents of the document were checked and are still valid. Thanks!! Version: 0 Date: 2006-05-11 User Name: 97195 Action: Update Started Comment: Need to make sure that this document is up to date with any developments on the HDS subsytems involved. Version: 0 Date: 2006-05-10 User Name: 71396 Action: Add Comment Comment: *** This is an automatic message. This document has received 0 hits in Sunsolve in 60 days (see http://krep.emea.sun.com/stats/dochistory.cgi?docid=80565 ). If it does not receive any hit in the next 30 days, it will be automatically archived. See http://kmo.central.sun.com/VAM/ for further details. *** Version: 0 Date: 2005-03-07 User Name: 31620 Action: Approved Comment: Verified Metadata Verified Keywords Verified still correct for audience - contract Checked review date 2006-03-02 Checked for TM - none needed Publishing Version: 3 Date: 2005-03-03 User Name: 31620 Action: Accept Comment: Version: 0 Date: 2005-03-02 User Name: 18329 Action: Approved Comment: The information is accurate Please check readability Version: 0 Date: 2005-03-02 User Name: 97195 Action: Approved Comment: Please review... Thanks!! Version: 0 Date: 2005-03-02 User Name: 97195 Action: Created Comment: Version: 0 Product_uuid f55c65ae-16a0-11d7-82ad-99701a4c6e31|Sun StorageTek 9900V Series Array 2a918ae2-0a18-11d6-834a-c679537eebe7|Sun StorageTek 9910 2a94fb3c-0a18-11d6-90a8-c9c08656284f|Sun StorageTek 9960 System Attachments This solution has no attachment |
||||||||||||
|