Asset ID: |
1-71-1012104.1 |
Update Date: | 2009-11-19 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1012104.1
:
Sun Enterprise[TM] 10000 Server: How to Create a New Domain
Related Items |
- Sun Enterprise 10000 Server
|
Related Categories |
- GCS>Sun Microsystems>Servers>High-End Servers
|
PreviouslyPublishedAs
216652
DescriptionThis document describes how to add a new two-board domain, using Sun direct attach boot storage to an existing Sun Enterprise[TM] 10000 platform.
You will use the System Service Process (SSP) as a boot server for the domain's new operating system. The SSP is a SPARC[TM] workstation or SPARC server that enables you to control and monitor the Sun Enterprise[TM] 10000 system. You can use a Sun Ultra[TM] 5 or Sun Enterprise[TM] 250 workstation, or a Sun Netra[TM] T1 server as an SSP.
Steps to FollowSun Enterprise[TM] 10000 Server: How to Create a New Domain
Complete Procedure for Creating a New Domain on a Sun Enterprise[TM] 10000 Platform.
---------------------------------------------------------------------------------------------------------------------------------
As an example, the procedure in this document creates a new domain called "bob" on a platform called "mye10k," using system boards 1 and 12, running the Solaris[TM] 8 Operating System on ip address 192.168.100.1.
Step 1. Inserting the New Hardware
---------------------------------------------------------
- Select 2 empty slots for the new boards to be inserted into, or select
present but unused System Boards currently in the platform.
- The domain must have the following to be able to support an operating
system.
- 1 to 4 CPUs on the system board.
- Memory (The system boards only support fully populated banks of
32 MB or 128 MB memory. Mixing memory in a board is not supported.)
- Sbus or PCI mezzanine with at least 1 supported Host Bus Adaptor
(HBA) for the boot.
- At least one Sbus or PCI network interface for the net boot from
the boot server.
- Insert the new hardware.
- On the MAIN ssp, Power on the new boards:
mye10k:bob% power -on -sb 1 12
Step 2. Running the Autoconfig Command
--------------------------------------------------------------------
CAUTION: Run the autoconfig command only on the new or moved boards. Incorrectly running the autoconfig command could cause running domains to fail.
- On MAIN SSP as user ssp:
mye10k:bob% setfailover off
- Run Autoconfig:
mye10k:bob% autoconfig sysboard1 (ensure there is no space between sysboard and board #)
Do not reboot yet
mye10k:bob% autoconfig sysboard12
Now reboot the SSP.
Note: in this case there is no need to sync the SSPs because failover is set to 'off'.
- When the SSP is back up (confirmed by running showfailover):
mye10k:bob% setfailover on (this should sync the SSP's)
Step 3. Preparing the SSP Domain Environment
-----------------------------------------------------------------------------
- Verify that you have a eeprom image for your domain that is NOT
being used for an existing domain.
- Log in to MAIN SSP as user ssp.
- mye10k:bob% cd $SSPVAR/.ssp_private/eeprom_save
- Select an unused eeprom image if you have one, for example,
eeprom.image_8:
mye10k:bob% mv eeprom.image_8 eeprom.image.bob
NOTE: It is always better to move the unused file to the name of
the domain rather than coping the file. Moving the unused file
reduces the chance of the file being reused and causing duplicate
host ids on your platform. If you do not have a spare image, request
a new key from Sun Microsystems so that you can create an image.
To create an image, use the Sun supplied key and serial number with
the sys_id command.
To determine if an image is used, you can check it's mac address and
compare to the current domains.
I.E.: mye10k:bob% sys_id -d -f eeprom.image_8
IDPROM in eeprom.image_8
Format = 0x01
Machine Type = 0x80
Ethernet Address = 0:0:be:a6:7f:9a
Manufacturing Date = Wed Dec 31 19:00:00 1969
Serial Number (Host ID) = 0xa67f9a
Checksum = 0x3f
- Create the new domain:
mye10k:bob% domain_create -d bob -b 1 12 -o 5.8 -p mye10k
Answer "Yes" to proceed.
Step 4. Powering on the Domain
----------------------------------------------------
- First change to the correct domain environment:
mye10k:joe% domain_switch bob
NOTE: Failure to change to the correct domain environment could result
in crashing an existing domain.
- Power on the boards, if they're not powered on already:
mye10k:bob% power -on -sb 1 12
mye10k:bob% bringup -A off (This is the equivalent of autoboot=false.)
The domain will now post with level 16 diagnostics.
- Confirm the domain passes a single pass level 16.
- Because this is all new hardware, re-run the bringup with a level
127 to fully test the hardware:
mye10k:bob% bringup -A off -l127
mye10k:bob% netcon -g (to connect to the domain after Open Boot PROM
handover)
<#0>ok
Step 5. Setting Up for Net Boot
-------------------------------------------------
- It is recommended to use a private network between the SSP and Domains
to install o/s. Or if the customer has a jumpstart server on the subnet
allready, point to that.
- Verify that the network interface you will use is connected to
the network:
<#0>ok watch-net-all (to check for traffic)
<#0>ok show-nets (to get path for nvalias cmd)
- Identify the interface to which the cable is connected:
<#0>ok nvalias bootnet <selected interface >
<#0>ok nvstore
- Confirm the Mac address (presuming a local_mac_address?=false):
<#0>ok banner
Ethernet address 0:0:be:b9:2b:3f (example Mac/ethernet address)
- As root on the SSP, add bob to /etc/hosts:
192.168.100.1 bob
- As root on the SSP, add bob to /etc/ethers:
0:0:be:b9:2b:3f bob
- Change directories to the boot image directory:
root# cd /export/install/8/Solaris_8/Tools
- Set up bootparams etc:
root# ./add_install_client bob sun4u
- On netcon session:
<#0>ok boot bootnet - install (or the equivalent for the Solaris 9 OS)
- Answer install questions. For the Solaris 8 OS
installation, select "no" reboot.
- root# ls -l /dev/rdsk/c0t0d0s0 (or the disk you installed the new OS on )
Take note of this path.
- root# /etc/halt
<#0>ok show-disks
- Select the path to disk above:
<#0>ok nvalias bootdisk <path to disk with new os >
<#0>ok nvstore
<#0>ok setenv boot-device=bootdisk bootnet
<#0>ok setenv diag-device=bootdisk bootnet
<#0>ok boot bootdisk
......
- Console login: ....
- Enter the following, which will allow you to correct the host
name and public ip address, if required:
root# sys-unconfig
- root# reboot
- Boot, configure to the correct addresses, and patch to EIS Standard.
NOTE: There are specific patches required on an Sun Enterprise 10000 domain above and beyond the standard recommended OS patch bundle. Contact your service representative for a list of these patches or source them from the EIS CD.
ProductSun Enterprise 10000 Server
Internal Comments
INTERNAL INFORMATION:
domain_create, install, starfire, e10k, autoconfig, domain, create, 10000
Previously Published As
74381
Change History
Date: 2009-11-19
User Name: Volkmar Grote 117021
Action: Reviewed for Content Team
Comment: removed links to 211921 and 211941 since I plan to archive them away
Date: 2005-01-25
User Name: 111868
Action: Approved
Comment: checked metadata
checked trademarks
checked expiry date
checked audience
publishing
Version: 9
Date: 2005-01-25
User Name: C140303
Action: Approved
Comment: Added another links in the internal section to the infodocs and the public section is links tothe public infodocs. Added TM to the Sun Enterprise in the doc.
Version: 0
Date: 2005-01-24
User Name: 111868
Action: Rejected
Comment: The following links:
Attachments