Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1011897.1 : T3 - How to create a mirror on a Sun StorEdge[TM] T3 array with an odd number of disks.
PreviouslyPublishedAs 216287 Description T3 - How to create a mirror on a Sun StorEdge[TM] T3 array with an odd number of disks. Steps to Follow DESCRIPTION: Creating a Raid-1 (mirror) out of an odd number of disks worked. The T3 mirroring algorithm was written to accommodate mirrors with odd-numbers of disks. The intent of this document is to explain how that works. CREATING THE VOLUME: Here is how one can create, via the CLI, a 3-disk RAID-1 (mirror). Each of the disks used here are 18GB. t3a:/:<10> vol add v1 data u1d1-3 raid 1 t3a:/:<11> vol init v1 data WARNING - Volume data will be initialized to zero. WARNING - Volume initialization can take a significant amount of time. Continue [N]: Y t3a:/:<12> vol list volume capacity raid data standby v1 26.8 GB 1 u1d1-3 none Note that a 3-disk mirror of 18GB (actually 17.9GB) disks yields 26.8GB of usable space. That's 17.9GB times 3, then divided by 2 because the data is mirrored. 17.9 x 3 -------- = 26.8 2 SO, HOW DOES THIS WORK WHAT'S REALLY GOING ON Assuming a 3-disk mirror, when one writes 6 blocks of data to the mirror LUN, the 6 blocks (and likewise, subsequent blocks) will be arranged on the 3 disks as shown below. The "D" refers to data, and the "M" refers to mirror. With the data arranged in this fashion, it is easy to see that if a disk fails, the data will still be available. disk-1 disk-2 disk-3 +------------------------- Data -> | blk1 blk2 blk3 Mirror -> | blk3 blk1 blk2 Data -> | blk4 blk5 blk6 Mirror -> | blk6 blk4 blk5 Product Sun StorageTek T3 Array Previously Published As 22450 Change History Date: 2003-11-14 User Name: 81292 Action: Approved Comment: KCCP: OK to publish Version: 0 Date: 2003-11-14 User Name: 38035 Action: Approved Comment: reviewed as part of the KM&O KCCP project; content is valid Version: 0 Date: 2003-11-04 User Name: 110334 Action: Rejected Comment: I'm not questioning the accuracy of the doc. It seems to be a duplicate. See previous comments. Version: 0 Product_uuid 2a6d7d50-0a18-11d6-8e0b-f0bd33b24928|Sun StorageTek T3 Array Attachments This solution has no attachment |
||||||||||||
|