Solution Type Technical Instruction Sure Solution 1011665.1 : Compatibility Between Sun StorEdge[TM] Fast Write Cache (FWCache) and Veritas Volume Manager Dynamic MultiPathing (DMP)
PreviouslyPublishedAs 215991 Steps to Follow The documentation for the "SUN StorEdge Fast Write Cache" (FWCache) product states that one should "avoid multiple paths to the data". This wording has been the cause of concern among Veritas Volume Manager users who use Volume Manager's DMP capability. However, there is no need for concern. Using DMP and FWCache together is fine. What is meant by "multiple paths" is one path THROUGH the cache and another path AROUND the cache. For example, if you have a disk referred to as c1t0d0 and a second path as c2t0d0, and you cache all reads and writes to c1t0d0 but do not cache reads/writes from/to c2t0d0, data corruption could occur. Everything is fine as long as it is the Volume Manager volumes that are being cached. Since VxVM and DMP are all below (logically speaking) the FWCache, everything is fine. Product VERITAS Volume Manager 3.0.2 Software Sun StorageTek Volume Manager 2.6 Sun StorageTek Fast Write Cache 2.0 (Localized) Sun StorageTek A5200 Array Sun StorageTek A5100 Array Sun StorageTek A5000 Array VxVM, Volume Manager, DMP Previously Published As 20594 Change History Date: 2006-01-18 User Name: 95826 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT Version: 0 Date: 2006-01-18 User Name: 95826 Action: Update Started Comment: SSH AUDIT Version: 0 Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : Neil Hickey comment : tm, title, properties date : Mar 22, 2002 updated by : Robert Belloni comment : changed properties date : Mar 7, 2002 updated by : Robert Belloni comment : changed Subject line date : Feb 13, 2002 updated by : Robert Belloni comment : removed internal comment date : Feb 12, 2002 updated by : Robert Belloni comment : checked spelling and added xml tags date : Feb 11, 2002 updated by : Karen Edwards comment : Not entered date : Sep 24, 1999 Version: 0 Product_uuid a99f8f3a-2bd5-11d6-87a3-e467d9c55f5e|VERITAS Volume Manager 3.0.2 Software a97aa3e6-2bd5-11d6-9f5c-a4660ab64573|Sun StorageTek Volume Manager 2.6 4518bfa5-e1bc-4a50-9ded-5611e82d1179|Sun StorageTek Fast Write Cache 2.0 (Localized) 2a8acc34-0a18-11d6-87ef-bd9528a0b933|Sun StorageTek A5200 Array 2a875298-0a18-11d6-8960-b3c71159a860|Sun StorageTek A5100 Array 2a83ce34-0a18-11d6-8498-8ec5d44f476b|Sun StorageTek A5000 Array Attachments This solution has no attachment |
||||||||||||
|