Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1011426.1 : Sun StorageTek[TM] 99x0 Systems: SNMP MIB
PreviouslyPublishedAs 215667 Description Sun StorageTek[TM] 99x0 Systems (STK99x0) sends SNMP trap to Network Management System (NMS) when unsolicited events happen on STK99x0 subsystem. The information on what is being sent to NMS is available in the STK99x0 MIB file. Steps to Follow Sun StorageTek[TM] 99x0 Systems: SNMP MIB STK99x0 SNMP installation is covered on both Web Console and Storage Navigator User guide. - STK99x0 SNMP sending trap OID .1.3.6.1.4.1.311.1.1.3.1.1 Given an OID, Solaris 10 Operating System can be used to find out where this SNMP trap comes from. /etc/snmp/conf/enterprises.oid shows: OID breakdown as follows: If this trap OID comes from STK99x0 SVP then SNMP trap OID should have Hitachi company number 1.3.6.1.4.1.116. In this case, Microsoft SNMP agent could have been used instead of Hitachi SNMP agent when binding the network properties on the SVP. Reselect the SNMP agent and use Hitachi SNMP agent on SVP. - STK99x0 OID 1.3.6.1.4.1.116.5.11.4.1.1.50.xx not in STK99x0 MIB file Standard STK99x0 MIB file does not give sufficient detail to decode the above OID. Unless it is advertised in SNMP MIB file then this information would only be useful on Hitachi Hi-Command management software. Note: More HDS MIB information is available externally, see http://www.oidview.com/mibs/116/HDS9900MIB.html which gives further detail breakdown on OID field. Product Sun StorageTek 9990 System Sun StorageTek 9985 System Sun StorageTek 9970 System Sun StorageTek 9980 System Sun StorageTek 9900V Series Array Sun StorageTek 9960 System Sun StorageTek 9910 System Internal Comments Additional Internal Information/References. SNMP - Simple Network Management Protocol - KGAP Request ID: 2765 STK99x0, StorEdge 99x0, 9910, 9960, 9970, 9980, 99xx, snmp, storage navigator, oid, mib Previously Published As 88572 Change History Date: 2007-02-28 User Name: 97961 Action: Approved Comment: - Applied trademarking where it is missing - Changed title to comply to the standard format - Made simple sentence/grammatical corrections Version: 4 Date: 2007-02-28 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2007-02-28 User Name: 128938 Action: Approved Comment: I had reviewed the document and the changes make to eradicate the possible confusion on its earlier version. Looks good to me. Sending for final review. Version: 0 Date: 2007-02-28 User Name: 87953 Action: Approved Comment: Discuss this issue with reviewer and some changes made. Sending back for review. Version: 0 Product_uuid 15644879-f179-11d8-ab63-080020a9ed93|Sun StorageTek 9990 System 73084edc-dc32-11d9-8a74-080020a9ed93|Sun StorageTek 9985 System 4ea4b951-9fc9-4f1f-b64e-69572a400fb4|Sun StorageTek 9970 System c2428fbe-8ab7-41d0-8b6e-ab489823c9d4|Sun StorageTek 9980 System f55c65ae-16a0-11d7-82ad-99701a4c6e31|Sun StorageTek 9900V Series Array 2a94fb3c-0a18-11d6-90a8-c9c08656284f|Sun StorageTek 9960 System 2a918ae2-0a18-11d6-834a-c679537eebe7|Sun StorageTek 9910 Attachments This solution has no attachment |
||||||||||||
|