Solution Type  Technical Instruction Sure

Solution  1010756.1 :   Sun Fire[TM] Mid-Range Servers ScApp Features and Requirements Matrix  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Netra 1280 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 4810 Server
  •  
  • Sun Netra 1290 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
214856


Applies to:

Sun Fire 6800 Server
Sun Fire E2900 Server
Sun Fire E4900 Server
Sun Fire E6900 Server
Sun Fire 4800 Server
All Platforms

Goal

This document provides an overview of the Sun Fire[TM]1280/E2900/3800/48x0/E4900/6800 & Sun Fire[TM] E6900 & Netra[TM]1280/1290 server's System Controller Application (ScApp) firmware version features & requirements.

Before upgrading ScApp, always read the Release Notes, Install.info file, and README file that are included with each version of the ScApp firmware patch.  The firmware revisions listed below are considered the minimum major and minor level needed to provide stable operation for the listed servers and features.  Running firmware levels earlier than those listed below puts the system at risk for bugs which have been fixed, will reduce the availability features engineered into newer  firmware, and may cause unnecessary instability.  If a system is operating on a firmware level below those listed in this document, it should be considered for upgrade as soon as scheduling permits.

For maximum availability and stability, engineering suggests domains operate Solaris 10 and System Controllers operate ScApp 5.20.X.

ScApp 5.21.x was released to support USBRDT-5240 boards which have been obsoleted.  As a result, ScApp 5.21.x has been obsoleted by 5.20.11 (patch 114527-12). Please upgrade your ScApp firmware as soon as possible to keep current. See <Document 1006281.1> to download and install the most current version of ScApp.

Solution

Description


Steps to Follow
The chart below contains Sun Fire Servers Features Matrix by ScApp Version.

Sun Fire Servers Features Matrix by ScApp Version.

Server, Component, or Feature

ScApp 5.16.x; Patch 114523-xx

ScApp 5.17.x; Patch 114524-xx

ScApp 5.18.x; Patch 114525-xx

ScApp 5.19.x; Patch 114526-xx

ScApp 5.20.x; Patch 114527-xx

SF3800-6800

Yes

Yes

Yes

Yes

Yes

E4900-6900

Yes

Yes

Yes

Yes

Yes

V1280/Netra1280/E2900

No

Yes

Yes

Yes

Yes

Supported USIII /USIII+ CPU Speeds

750, 900, 1050, 1200, MHz

750, 900, 1050, 1200, MHz

750, 900, 1050, 1200, MHz

750, 900, 1050, 1200, MHz

750, 900, 1050, 1200, MHz

Supported USIV/USIV+ CPU Speeds

1050, 1200 MHz

1050, 1200 MHz

1050, 1200, 1350 MHz

1050, 1200, 1350, 1500 MHz

1050, 1200, 1350, 1500, 1800, 1950*  MHz

 *ScApp 5.20.3

SC V2 (Enhanced-Memory System Controller)

Yes

Yes

Yes

Yes

Yes

PCI+ I/O Assembly

No

Yes

Yes

Yes

Yes

PCI  (XMITS 3.1) (TBA)

No

No

No

No

Yes

System Controller Failover

Yes

Yes

Yes

Yes

Yes

Dynamic Reconfiguration Supported

Yes (S8 & 9 only)

Yes (S8 & 9 only)

Yes (S8-10)

Yes (S8-10)

Yes (S8-10)

Domain DR patch requirements

S8 02/02 KJP 108528-14 & 111111-01, 112396-02, 108987-09, 111097-08

S9 KJP 11233-01

S8 02/02 KJP 108528-14 & 111111-01, 112396-02, 108987-09, 111097-08

S9 KJP 11233-01

S 8 02/02 KJP 108528-14 & 111111-01, 112396-02, 108987-09, 111097-08

S9 KJP 11233-01

S10

S8 02/02 KJP 108528-14 & 111111-01, 112396-02, 108987-09, 111097-08

S9 KJP 11233-01

S10

S8 02/02 KJP 108528-14 & 111111-01, 112396-02, 108987-09, 111097-08

S9 KJP 11233-01

S10

Server, Component, or Feature

ScApp 5.16.x; Patch 114523-xx

ScApp 5.17.x; Patch 114524-xx

ScApp 5.18.x; Patch 114525-xx

ScApp 5.19.x; Patch 114526-xx

ScApp 5.20.x; Patch 114527-xx

Capacity On Demand   Demand(COD)

3800-6800

3800-6800 & E4900-6900

3800-6800 & E4900-6900

3800-6800, E4900-E6900, v1280, E2900, & Netra1280/1290

3800-6800, E4900-E6900, v1280, E2900, & Netra1280/1290

setls

Yes

Yes

Yes

Yes

Yes

SunMC version

3.0 Update 4

3.5

3.0 Update 4

3.5

3.5

3..6.1

3.6.1

Secure Shell(SSH) Protocol

*(a) SF3800-6800 & E4900-E6900

*(b) v1280, Netra1280/1290, E2900

3800-6800 & E4900-E6900

3800-6800, E4900-E6900, v1280, E2900, & Netra1280/1290

* Requires SC V2 for v1280, E2900, & Netra 1280/1290.

3800-6800, E4900-E6900, v1280, E2900, & Netra1280/1290

* Requires SC V2 for v1280, E2900, & Netra 1280/1290.

3800-6800, E4900-E6900, v1280, E2900, & Netra1280/1290

* Requires SC V2 for v1280, E2900, & Netra 1280/1290.

3800-6800, E4900-E6900, v1280, E2900, & Netra1280/1290

* Requires SC V2 for v1280, E2900, & Netra 1280/1290.

Domain MAC / HostID *(1)

Yes

Yes

Yes

Yes

Yes

Domain hang recovery *(2)

Yes

Yes

Yes

Yes

Yes

Component Health Status

(CHS) *(3)

Yes

Yes

Yes

Yes

Yes

Repeated Domain Panic Recovery *(4)

Yes

Yes

Yes

Yes

Yes

Persistent Update of CHS by Solaris[TM] OE for CPU offline L2_SRAM conditions *(5)

Yes

*Requires minimum of Solaris 8 KJP 108528-29 or Solaris 9 KJP 11233-09 w/patch 116009-01 or  Solaris 10

Persistent Logging of system errors, SC platform logs and SC domain logs * (6)

No

Yes

* Requires SCV2

Yes

* Requires SCV2

Yes

* Requires SCV2

Yes

* Requires SCV2

Server, Component, or Feature

ScApp 5.16.x; Patch 114523-xx

ScApp 5.17.x; Patch 114524-xx

ScApp 5.18.x; Patch 114425-xx

ScApp 5.19.x; Patch 114526-xx

ScApp 5.20.x; Patch 114527-xx

VCMON

No

No

Yes * (7)

Yes   * (7)

Yes * (7)

Processor Offlining due to VCMON

No

No

No

Yes

Yes *(11)

CPU Diagnosis Engine * (8)

No

No

No

Yes

Yes

ECC Diagnosis Engine * (9)

No

No

No

Yes

Yes

max-panic-diag-level parameter * (10)

No

No

No

Yes

Yes

CHS updated for components identified by VCMON * (11)

No

No

No

Yes

Yes

Solaris 10 Ready,

(FMA) persistent off-lining of discovered faults

No

No

No

No

Yes *(3), *(9)

*Additional Details for Sun Fire Mid-Range Server Features

  1. 3800-6800 and E4900-E6900 systems support up to 5 SSH connections in total. Only one SSH connection is allowed per Domain  plus  one  SSH connection to the Platform shell.

  2. V1280,Netra1280/1290, and E2900 systems support  up to 2 SSH connections using firmware 5.18.x..

* Summary Description of each  Sun Fire Mid-Range Servers Availability Feature

  1. Domain MAC/HostID can be swapped between Domains. Example: MAC/HostID from Domain A can be swapped to Domain C. Allows more flexibility in configuration and will not interfere with licensing requirements.

  2. SC monitors Domain heartbeat. If heartbeat or interrupts quit responding, SC initiates a reset of the Domain or posts a NOTIFY message depending on the setting of the hang-policy  Domain variable.

  3. Persistent record of event information stored in the component. Ensures faulty components will not be configured into a Domain.

  4. Run power on-self test (POST) at increasing diagnosis levels to identify and isolate faulty hardware (if any).

  5. SC can receive hardware failure messages from Solaris OS for specific events

  6. System error messages and 6 levels of messages in domain and platform logs are retained in additional memory if using SCV2 (enhanced-memory System Controller).  These persistent logs are also retained across reboots.  Six levels of messages stored: alert, critical, emergency, error, fault, and warning.

  7. Voltage Core Monitor. Proactive monitoring and analysis of CPU core voltage levels to identify CPU boards which may be at risk for experiencing certain identified types of failures.

  8. Diagnoses specific fatal and non-fatal CPU events.

  9. Correlates collected parity and ECC information to detect bad writers and bad readers, diagnose signaling events (Syndrome 0x071), and identify components which experience a specified number of ECC events in a specified time period when possible.

  10. The maximum POST diag-level used in Automated Recovery from Repeated Domain Panics  is now tunable.

  11. CHS is now updated for components identified by VCMON.

Minimum ScApp & OS Requirements by Platform or Board Type

Hardware/System Board Type

ScApp

Solaris 8

Solaris 9

Solaris 10

3800-6800

5.18.5

Solaris 8 KJP 108528-29

Solaris 9 KJP 112233-12 w/ patch 116009-05

Solaris 10 3/05

E4900-E6900

5.18.5

Solaris 8 KJP 108528-29

Solaris 9 U6

Solaris 10 3/05

v1280, Netra1280/1290, & E2900

5.18.5

Solaris 8 KJP 108528-29

Solaris 9 KJP 112233-09 w/patch 116009-01

Solaris 10 3/05

USIV 1050, 1200 or 1350 MHz

5.18.5

Solaris 8 2/04

Solaris 9 4/04

Solaris 10 3/05

US IV + 1500, 1800 and 1950 MHz *(1)

5.19.2

No

Solaris 9 9/05

Solaris 10 3/05

*(1) For 6800/E6900, which can be configured with dual domains per partition (Domains A&B and C&D), in order to support dual domains per partition with USIV+ SBs, you must have Version 2 (V2) Repeaters (RPs) installed and at least ScApp 5.20.1.  See Technical Instruction: for details.

Minimum Requirements for Availability (AVL) Features in Solaris

Availability Feature

Solaris 8

Solaris 9

Solaris 10

CPU off-lining for L2_SRAM events

Solaris 8 KJP 108528-29

Solaris 9 KJP 112233-12

Solaris 10 3/05

Memory Page Retirement

Solaris 8 KJP 108528-29 & 117000-03

Solaris 9 KJP 112233-12

Solaris 10 3/05

Fault management Architecture (FMA) 

No

No

Solaris 10 3/05

CPU Level 2/Level 3 (L2/L3) cache-line retirement

No

Solaris 9 KJP 122300-28

Solaris 10 KJP 137111-02

ScApp Availability (AVL) Enhancement Information:

For a thorough understanding of availability functionality included in ScApp firmware, review the following Blueprint documents related to this feature:

  * Sun Fire 6800/4810/4800/3800 Systems Auto Diagnosis and Recovery Features (pdf), which describes the Availability feature's introduction in ScApp 5.15.0.

  * Sun Fire 6800/4810/4800/3800 Systems Auto Diagnosis and Recovery Enhancements (pdf) which describes the first set of enhancements to the feature included in ScApp 5.15.3.

  * Sun Fire Midrange Servers Auto-Diagnosis and Recovery Features (pdf) which describes the next enhancement to this feature in ScApp 5.17.0.

  * Auto Diagnosis and Recovery Enhancements for Sun Fire Midrange Servers Updated for Firmware Release 5.19.0 ( pdf ) which describes the latest enhancements made to ScApp 5.19.0 and in 5.20.x as well.



Some of the links at the bottom are old Sun Links, but we don't know yet where to point them, or if they will move.
 
Serengeti, lw8, 1280, 2900, 3800, 4800, 6800, 6900, netra, sunfire, sun fire, ScApp, Firmware, Dynamic Reconfiguration, DR, Availability, vcmon, USIV, USIV+, FMA, pci+, pci
Previously Published As
76235




Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback