Solution Type  Technical Instruction Sure

Solution  1010684.1 :   The reset -x command is not applicable to LOMlite (Netra[TM] t1 10x / Netra[TM] t 140x) systems  


Related Items
  • Sun Netra T1405 Server
  •  
  • OpenSolaris Operating System
  •  
  • Sun Netra T1100 Server
  •  
  • Sun Netra T1400 Server
  •  
  • Sun Netra T1125 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>NEBS-Certified Servers
  •  

PreviouslyPublishedAs
214755


Description
From the Lights Out Management (LOM) environment on a Netra[TM] t1 10x or Netra[TM] t 140x machine, you are unable to issue the "lom> reset -x" command to perform an XIR (externally intitiated reset) in order to reset the host and leave the server at the ok prompt / Open Boot Prom (OBP) environment.

LOMlite does not have this capability, LOMlite2 does.



Steps to Follow
The Netra t1 10x and Netra t 140x (which use LOM v1, aka LOMlite) do not have the reset -x command option available to perform an XIR and drop to the ok prompt.
The reset command will reset the server, but the Open Boot Prom parameters (auto-boot?) will determine whether the machine will automatically boot back up into the OS or not.

LOMlite2 does include a reset -x command to perform an XIR and leave the system at the ok prompt / Open Boot Prom (OBP) environment.

Here is a listing of which versions of LOMlite apply to which Hardware platforms:

LOMlite

  • Netra[TM] t1 10x
  • Netra[TM] t 140x

LOMlite2

  • Netra[TM] T1 AC/DC200
  • Netra[TM] X1
  • Sun Fire[TM] V100/V120
  • Netra[TM] 120
  • Netra[TM] 20
  • Netra[TM] T4


Product
Netra t 1405 Server
Netra t 1400 Server
Netra t 1125 Server
Netra t1 model 100 Server
Lights Out Management Module

Internal Comments
For more Lights Out Management (LOM) information, please review the link below:

http://pts-americas.east/vsp/netra/products/lom/lom.html
LOM, LOMlite, LOMlite2, Netra
Previously Published As
77797

Change History
Date: 2004-09-03
User Name: 71176
Action: Approved
Comment: Some reformating and editing metadata. Ok to publish.
Version: 3
Date: 2004-09-03
User Name: 71176
Action: Accept
Comment:
Version: 0
Date: 2004-08-31
User Name: 108410
Action: Approved
Comment: Please Review.
Thanks
Rick
Version: 0
Product_uuid
2987c724-0a18-11d6-8417-9b7af7cfcdc8|Netra t 1405 Server
29848992-0a18-11d6-9888-8e67670fef2c|Netra t 1400 Server
2981306c-0a18-11d6-93e9-a04bcf4c73e8|Netra t 1125 Server
29951dfc-0a18-11d6-9442-fc86d740f963|Netra t1 model 100 Server
d6a0fb85-c35f-4b5e-95fc-076f7c2f6f67|Lights Out Management Module

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback