Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1010655.1
Update Date:2011-06-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1010655.1 :   Where can I get the service mode password for a Sun Fire[TM] 3800/48x0/6800/E4900/E6900/E2900/V1280 and Netra[TM] 1280/1290 server?  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Netra 1280 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Fire 4810 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  
  • GCS>Sun Microsystems>Servers>NEBS-Certified Servers
  •  

PreviouslyPublishedAs
214689


Applies to:

Sun Netra 1290 Server
Sun Fire 4800 Server
Sun Fire V1280 Server
Sun Netra 1280 Server
Sun Fire 3800 Server
All Platforms

Goal

Service Mode is expected to be used only under the direct supervision of a Sun Authorized Service Provider (a Sun Solution Center Engineer or Sun badged Field Engineer).
Service Mode is used only for specific service related procedures, such as:

  • Resetting a component's CHS status (See <Document: 1004879.1>)
  • Resetting the LOM password on a Sun Fire[TM] v1280, E2900 or Netra[TM] 1280, 1290 (See <Document: 1005086.1>)


It is preferred that Service Mode procedures be performed by a Sun Solution Center Engineer utilizing Sun Shared Shell.

  • By using Sun Shared Shell, the customer will be able to watch the procedure you perform while it happens but will not have access to Service Mode.


Solution


Steps to Follow
Follow this procedure in order to obtain a Service Mode password.
The following System Controller information is required prior to obtaining a Service Mode password:
  • System Controller HostID
  • ScApp Version
  • RTOS Version
The above information can be obtained from the system controller keying in "service" followed by RETURN twice at the SC platform shell.  Example output as follows:
sc0:SC> service
The use of service commands can be destructive and destabilize the
system. Use of service mode is authorized only by personnel trained
in its use.

Enter Password:
Invalid password.

HostID: 8302436a
ScApp version: 5.18.0
RTOS version: 41

Note that showsc -v output to obtain information can be imprecise, as some systems (eg: V1280, E2900) will return different values for hostid than you are expecting.

The showsc command shows the DOMAIN hostid, not the SC's hostid.

Use ONLY the procedure above using the 'service' command.


NOTE:


If the system is running ScApp 5.20.15 or higher 

the CHS status can be reset from the SC or lom prompt by anyone who can login to the Main SC and no special access is required at all.

Generate the Service Password.

A Service Mode password can be obtained from the following internal Sun website:
https://sfservicepass.us.oracle.com/

A backup password generator is located at https://sfservicepass-bak.uk/

ATTENTION:

  • Service Mode access should, whenever possible, not be provided to a customer

  • Do not dispatch a case to the field to perform a Service Mode procedure when you can utilize Sun Shared Shell instead.


When Sun Shared Shell is not an option, a customer can be directly supervised as they perform the suggested procedure.

  • This is not a preferred option by any means and it is your responsibility to ensure that Service Mode's use is appropriately controlled.

  • If proceeding with this option, you should "walk the customer" through the exact commands and steps which are being entered as they are needed.                             

  • Do not simply provide an emailed list of commands for their later use (this would be "unsupervised" use).

  • When a procedure is completed, have the customer exit Service Mode and remind them that they should not re-enter Service Mode again.

serengeti, lw8, Serengeti, LW8, sunfire, sun fire, service, mode, service mode, CHS, reset, LOM, setchs, showchs, password





Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback