Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1010650.1 : StorEdge L20,L40,L60 - Technical Instruction: Configuring Ethernet port for Firmware Upgrade or Remote Management
PreviouslyPublishedAs 214682
Applies to:Sun Storage L20 (StorEdge-OEM) Tape Library - Version: Not Applicable and later [Release: N/A and later]Sun Storage L40 (StorEdge-OEM) Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun Storage L60 (OEM) Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 2-Feb-2011. GoalDescriptionCustomers and Field Staff who need to upgrade Robotics Firmware on the L20 L40 and L60 Tape libraries May not find complete documentation on setting up the RJ45 Ethernet port on the Remote Management board. Use of this port is required for doing firmware upgrades on the tape library. This document is intended to supplement information in the following document...
Patch-ID. 111972 SolutionSteps to FollowWhen a firmware upgrade is necessary on L20, L40 and L60 tape libraries the Ethernet RJ45 connector on the library RMC (Remote management card) must be configured. The documentation in patch id # 111972 (step 2) assumes this is already done but the library setup and user instructions are not always available.
Note: To check current firmware versions use...
SETUP
2. Using the front panel (+ - ) buttons Set an appropriate IP address, Netmask, and Gateway (Gateway may only be required if connecting library to a Network.) 3. Navigate to, and set an administrator password for the library. 4. Cycle the power on the library.
HOST SYSTEM
Note 1: the browser must support Java 1.3x, If you are having unsupported Browser problems please contact Sun Service. Note 2: If the library is not being permanently connected to a LAN then you can use an Ethernet crossover cable to provide a temporary connection between the host and the Library RMC and an ip address can be randomly selected.
Prepare Browser Host for Firmware download
2. Ensure patch Patch-ID# 111972 is loaded onto the host and uncompressed/un- tar'd 3. Open your Browser and type the ip address for the tape library in the URL field. If all is connected and configured correctly you should see a library menu. 4. If prompted to accept the certificate you need to chose YES/OK. 5. Follow the instructions in Patch-ID# 111972 readme to upgrade firmware. L20, L40, L60, Firmware, Network RJ45 configure Previously Published As 70314 Change History Date: 2004-11-03 User Name: 31620 Action: Approved Comment: Publishing Version: 3 Date: 2004-10-29 User Name: 31620 Action: Accept Comment: Version: 0 Date: 2004-10-29 User Name: 38429 Action: Approved Comment: no edits Version: 0 Attachments This solution has no attachment |
||||||||||||
|