Solution  1010598.1 :   How to reset the System Controller (SC) password on a Sun Fire[TM] B1600 System  


Related Items
  • Sun Fire B1600 Blade System Chassis
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Blade Servers
  •  

PreviouslyPublishedAs
214581


Description
This Procedure can be used to bypass and reset the ALOM password of
Sun Fire[TM] B1600 with one and two System Controller.

Symptoms:

  • Can't login
  • Can't connect
Purpose/Scope:

This document describes a procedure which can be used to bypass and reset the ALOM password of  Sun Fire B1600 systems with one and two System Controllers (SCs)


Steps to Follow
The procedure to bypass the ALOM password is as follows:

Step 1.Setup a serial connection with the active System Controller.

Step 2. Remove and then re-insert one of the power supplies.

You are going to see a message like this:

(The first three lines are showing the moment when the password failed, the rest show when the power was removed and inserted).

---------------------------------------------------------------------

username: admin
password:
Login incorrect.

Dec 17 14:21:06: CRITICAL: PS1: AC input fault.
Dec 17 14:21:06: MINOR: PS1: Removed.
Dec 17 14:21:06: MINOR: PS1: Environmental monitoring disabled.
Dec 17 14:21:07: CRITICAL: PS1 removed - replace within 10 minutes of removal
Dec 17 14:21:08: MINOR: CH: Locator LED state changed to FLASHING.
Dec 17 14:21:13: MINOR: PS1: Inserted.
Dec 17 14:21:14: MINOR: CH: Locator LED state changed to OFF.
Dec 17 14:21:14: MINOR: PS1: Service Required LED state changed to OFF.
Dec 17 14:21:15: MINOR: PS1: Ready to Remove LED state changed to OFF.
Dec 17 14:21:16: MAJOR: PS1: Dynamic FRUID packet discovery failure recovered.
Dec 17 14:21:18: MINOR: PS1: Environmental monitoring enabled.

------------------------------------------------------------------------



Step 3. Within five minutes of re-inserting the power supply, in the serial connection to the SSC containing the active System Controller, log in as user admin.

To log in, type the default user name admin and when prompted for a password, press [ENTER].:

username: admin
password: <enter>

->

Note: This procedure is documented in the "Sun Fire B1600 Blade System Chassis Product Notes"(816-4174) and complements the procedure recommended in the manual "Sun Fire B1600 Blade System Chassis Administration Guide"(816-4765)



Product
Sun Fire B1600 Blade System Chassis

Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

Domain Lead: [email protected]
Feedback Alias: [email protected]

normalized, b1600, stilleto, password, alom, bypass
Previously Published As
73112

Change History
Date: 2008-09-24
User Name: 79977
Action: Updated
Comment: Added normalized keyword
Version:

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback