Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1010542.1
Update Date:2009-01-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1010542.1 :   Sun StorEdge[TM] 3310: Seeing more than 8 LUNs when the array is attached to a host's on-board SCSI port  


Related Items
  • Sun Storage 3310 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
214494


Description
As documented in the Sun StorEdge[TM] 3310 SCSI Array Release Notes (816-7292), the Sun StorEdge [TM] 3310 is supported on the on-board SCSI port of some servers, including the following :

Sun Fire[TM] V250,
Sun Fire[TM] V240,
Sun Fire[TM] V440,
Sun Fire[TM] V1280.

This onboard SCSI port uses the "glm" SCSI driver. By default, only 8 luns are recognized per target by the glm driver. This document explains how to configure more than 8 luns per target.



Steps to Follow
In order for the glm driver to recognize more than 8 luns per target on the StorEdge 3310, the default "scsi-options" need to be modified. There are two ways to do this :

1. GLOBALLY - not recommended

The following line can be added in the /etc/system file :

set scsi_options=0x43ff8

A host reboot is required to make this active.

Caution: Adding this line in the /etc/system file is not recommended as it will affect ALL SCSI bus on the system, not just the SCSI bus to the Sun StorEdge [TM] 3310

2. LOCALLY - recommended

The following entry can be added to the /kernel/drv/glm.conf :

device-type-scsi-options-list = "SUN     StorEdge 3310", "SE3310-scsi-options";
SE3310-scsi-options = 0x43ff8;

Make sure that there are exactly five spaces between "SUN" and "StorEdge" in the entry "SUN StorEdge 3310". Also ensure there is no newline after the = sign.

If /kernel/drv/glm.conf does not already exist, create it, containing just the recommended entry.

A host reboot is required to make this activ



Product
Sun StorageTek 3310 SCSI Array

Internal Comments
For the internal use of Sun Employee's.

See Bug ID: 4844899 for more background information.


glm, glm.conf, Sun StorEdge 3310, on-board SCSI, scsi-options
Previously Published As
73192

Change History
Date: 2007-10-09
User Name: 7058
Action: Update Canceled
Comment: *** Restored Published Content *** Delete working copy. Existing published copy stays on sunsolve. IBIS migration prep.
Version: 0
Date: 2007-10-09
User Name: 7058
Action: Reassign
Comment: Delete working copy. Existing published copy stays on sunsolve. IBIS migration prep.
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.