Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1010491.1
Update Date:2009-09-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1010491.1 :   N1[TM] Provisioning Server Software:Changing the password of a Sun Fire[TM] B1600 System Controller  


Related Items
  • Sun Fire B1600 Blade System Chassis
  •  
  • Sun N1 Service Provisioning System
  •  
Related Categories
  • GCS>Sun Microsystems>Enterprise Computing>Sun N1 System
  •  

PreviouslyPublishedAs
214406


Description
The customer wanted to know how to change the password on the chassis SC
(system controller) and update the N1 Grid PS database with that new
username and/or password.

Steps to Follow
To change the password of the chassis SC in the database run the following
commands as root:
device -s -p <device ID>
e.g.
#/opt/terraspring/sbin/device -s -p 50160
The tool will prompt the user for the old password.
The tool will then prompt the user to enter the new password and confirm
the password (enter the password a second time).
To change the password on the chassis SC itself, run the password command:
e.g.
SC>password
Enter current password: *****
Enter new password: ****
Enter new password again: ****
Now the new password is on the Chassis SC and in the N1 Grip PS database.
Mike Olmstead
N1 Specialty Team


Product
Sun N1 Provisioning Server 3.0 Software, Blades Edition
Sun Fire B1600 Blade System Chassis

N1, N1 ps, provisioning server
Previously Published As
74766

Change History
Date: 2006-06-21
User Name: 71396
Action: Add Comment
Comment: *** This is an automatic message. This document has received 0 hits in Sunsolve in 60 days (see http://krep.emea.sun.com/stats/dochistory.cgi?docid=74766 ). If it does not receive any hit in the next 30 days, it will be automatically archived. See http://kmo.central.sun.com/VAM/ for further details. ***
Version: 0
Date: 2006-01-19
User Name: 25440
Action: Update Canceled
Comment: *** Restored Published Content *** SSH AUDIT
Version: 0
Date: 2006-01-19
User Name: 25440
Action: Update Started
Comment: SSH AUDIT
Version: 0
Date: 2004-04-02
User Name: 13128
Action: Approved
Comment: KE quality checklist applied
Version: 0
Date: 2004-04-01
User Name: 13128
Action: Accepted
Comment:
Version: 0
Date: 2004-04-01
User Name: 96838
Action: Approved
Comment: Thanks a lot Mike.
Version: 0
Date: 2004-04-01
User Name: 96838
Action: Accepted
Comment:
Version: 0
Date: 2004-04-01
User Name: 122356
Action: Unlock
Comment:
Version: 0
Date: 2004-04-01
User Name: 122356
Action: Add Comment
Comment: The infodoc look all set .Its great to know you can change the password through this procedure.
Thanks
Version: 0
Date: 2004-04-01
User Name: 122356
Action: Accepted
Comment:
Version: 0
Date: 2004-04-01
User Name: 142270
Action: Approved
Comment: I meant to send this for tech review some time ago. Anyway, it is ready now.
-Mike Olmstead
Version: 0
Date: 2004-03-16
User Name: 142270
Action: Created
Comment:
Version: 0
Product_uuid
c0bf7a66-11dc-11d7-8fef-cceb9f78f141|Sun N1 Provisioning Server 3.0 Software, Blades Edition
10bec5e4-5865-11d6-9ffc-c65b6cd3fd7d|Sun Fire B1600 Blade System Chassis

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.