Solution Type Technical Instruction Sure Solution 1010131.1 : Pinouts for signals on a splitter cable required for the A/B port on an Sun Enterprise[TM] 450 (E450).
PreviouslyPublishedAs 213915 Steps to Follow Make your cable to match the signal as follows. Pin Number Function Serial Port Description ----------------------------------------------------------- 1 none none none 2 TXD A transmit data 3 RXD A receive data 4 RTS A ready to send 5 CTS A clear to send 6 DSR A data set ready 7 GND Ground 8 DCD A data carrier detect 9 none none none 10 none none none 11 DTR B data terminal ready 12 DCD B data carrier detect 13 CTS B clear to send 14 TXD B transmit data 15 TRC A transmit clock 16 RXD B receive data 17 RXC A receive clock 18 RXC B receive clock 19 RTS B ready to send 20 DTR A data terminal ready 21 none none none 22 none none none 23 none none none 24 TXC A transmit clock 25 TXC B transmit clock Product Sun Enterprise 450 Server Previously Published As 21148 Change History Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : Laurie Hutchins comment : Verified as technically accurate by Hardware-systems. Reviewed by KE. date : May 25, 2000 updated by : Michael Buckley comment : Appears to be accurate. date : May 19, 2000 updated by : Michael Buckley comment : Appears to be accurate. date : May 19, 2000 updated by : No owner comment : changed the synopsis from: "How do split the serail a/b pinouts" to: "How to split the serial a/b pinouts" d ai date : Nov 15, 1999 Version: 0 Product_uuid 29656238-0a18-11d6-91d9-a4e449afd809|Sun Enterprise 450 Server Attachments This solution has no attachment |
||||||||||||
|