Asset ID: |
1-71-1009934.1 |
Update Date: | 2011-05-23 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1009934.1
:
Sun StorageTek[TM] 6540 Firmware Matrix
Related Items |
- Sun Storage 6540 Array
- Sun Storage Common Array Manager (CAM)
|
Related Categories |
- GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
|
PreviouslyPublishedAs
213616
This article documents Sun StorageTek 6540 Array's components firmware baseline bundled in each corresponding CAM release and patched versions.
In this Document
Goal
Solution
Applies to:
Sun Storage 6540 Array
Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later]
All Platforms
Goal
This article documents Sun StorageTek 6540 Array's components
firmware baseline bundled in each corresponding CAM release and patched
versions.
This document assumes the relevant array product is managed with Common
Array Manager. This reference can be used by end-user and all levels
of support personnel for purpose of verifying component firmware and
management software compatibility.
For instructions to download CAM, please refer to <Document 1296274.1>
How to Download Common Array Manager (CAM) Software and Patches.
Solution
Baseline / CAM Release |
Sun StorageTek 6540 Firmware |
Patch |
Controller |
Expansion |
Firmware |
NVSRAM |
CSM100 FC |
CSM100 SATA |
CSM200 |
FLA200 FC |
FLA300 FC |
FLC200 dSATA |
FLC200 iSATA |
1.0 |
no support |
1.1 |
1.2 |
1.3 |
2.0 |
2.1 |
Naming convention changed. Version following 2.1 is 5.0. There was no 3.x or 4.x.
|
no support |
|
no support |
5.0 |
121540-02 |
06.16.81.10 |
N6091-616843-005 |
9865 |
5.0.1 |
121540-02 |
06.16.81.10 |
N6091-616843-005 |
9865 |
5.0.2 |
121540-02 |
06.16.81.10 |
N6091-616843-005 |
9865 |
5.0.2 |
124946-01
118185-26
|
|
9867a |
5.1.0.10 |
121540-04 |
06.19.23.10b |
N6091-619843-002b |
9643 |
9726 |
9884 |
5.1.0.11 |
121540-04 |
06.19.25.10 |
N6091-619843-002 |
9643 |
9726 |
9884 |
5.1.2.2 |
121540-04 |
06.19.25.10 |
N6091-619843-002 |
9643 |
9726 |
9884 |
5.1.3.2 |
121540-04 |
06.19.25.10 |
N6091-619843-002 |
9643 |
9726 |
9884 |
5.1.3.2 |
controlled |
06.19.25.13d |
|
5.1.3.2 |
controlled |
06.19.25.14d |
|
6.0.0.10 |
n/a |
06.19.25.16 |
N6091-619843-002 |
9643 |
9726 |
9887 |
9330 |
9643 |
9565 |
9726 |
6.0.1.11 |
n/a |
06.19.25.16 |
N6091-619843-002 |
9643 |
9726 |
9887 |
9330 |
9643 |
9565 |
9726 |
6.1.0.16
|
n/a |
06.60.11.10 |
N6091-660843-003 |
9643 |
9726 |
98B4 |
9330 |
9643 |
9565 |
9726 |
07.10.25.10f |
N6091-710843-005f |
9673 |
9728 |
9566 |
9728 |
6.1.0.16
|
137934-02
137935-02
137936-02
|
|
|
07.10.25.10 |
N6091-710843-005 |
6.1.1.10
|
n/a |
06.60.11.10 |
N6091-660843-003 |
9643 |
9726 |
98B4 |
9330 |
9643 |
9565 |
9726 |
07.10.25.10f |
N6091-710843-005f |
9673 |
9728 |
9566 |
9728 |
6.1.1.10
|
139034-01
139035-01
139036-01
|
|
|
07.10.25.10 |
N6091-710843-005 |
6.1.2.8
|
n/a |
06.60.11.10 |
N6091-660843-003 |
9643 |
9726 |
98B4 |
9330 |
9643 |
9565 |
9726 |
07.10.25.10h |
N6091-710843-005h |
9673 |
9728 |
9566 |
9728 |
6.2.0.13
|
|
06.60.11.10 |
N6091-660843-003 |
9681 |
9728 |
98C1 |
9330 |
9681 |
9566 |
9728 |
07.15.11.11i |
N6091-710843-005 |
6.2.0.14
|
140060-01
140061-01
140062-01
|
|
|
07.15.11.12j |
|
6.2.0.14
|
140060-02
140061-02
140062-02
|
|
|
07.15.11.12j |
|
6.3.0
|
|
(CAM 6.3 was never released.)
|
6.4.0.10
|
|
06.60.11.10 |
N6091-660843-003 |
9681 |
9728 |
98C4 |
9330 |
9681 |
9566 |
9728 |
07.50.08.10
|
N6091-750843-003 |
6.4.1.5
|
|
06.60.22.10 |
N6091-660843-003 |
9682 |
9728 |
98C4 |
9330 |
9682 |
9566 |
9728 |
07.50.13.10 |
N6091-750843-003 |
6.5.0.10
|
|
06.60.22.10 |
N6091-660843-003 |
9682 |
9728 |
98C4 |
9330 |
9682 |
9566 |
9728 |
07.60.18.10 |
N6091-760843-003 |
6.5.0.x
|
controlled
|
(06.60.22.10) |
N6091-660843-039k |
|
(07.1x.xx.xx)
(07.50.xx.xx)
(07.60.18.10)
|
N6091-710843-059k
N6091-750843-039k
N6091-760843-039k
|
6.6.0.11l
|
|
06.60.22.10 |
N6091-660843-003 |
9682 |
9728 |
98D0 |
9330 |
9682 |
9566 |
9728 |
07.60.18.13 |
N6091-760843-004 |
6.6.0.12l
|
141474-01l
141475-01
141476-01
|
(CR6935284 CAM BUI host types do not match array hostregion.)
|
6.6.0.12
|
143759-01
143760-01
143761-01
|
|
|
07.60.36.10 |
|
6.7.0.12
|
|
06.60.22.10 |
N6091-660843-003 |
9682 |
9728 |
98D3 |
9330 |
9682 |
9566 |
9728 |
07.60.36.13 |
N6091-760843-004 |
6.7.0.13 (Windows Only)
|
144861-01
|
(CAM core patch for Windows only. Fixes CR6968739 J4410 reporting incorrect chassis serial number; and CR6972298 Win2008 undefined constant.)
|
6.7.0.x
|
145965-02
145966-02
145967-02
|
|
(Seagate drives firmware fixes for 6000/2500/J4000; 6000/2500 controller firmware fixes.
Includes all previous fixes in 14596[567]-*.)
|
07.60.53.10 |
|
6.7.0.x
|
145965-03
145966-03
145967-03
|
|
(For F5100 FMOD firmware fixes FMODs zombie during db restore operation.
Includes all previous fixes in 14596[567]-*.)
|
07.60.53.10 |
|
Baseline / CAM Release |
Patch |
Firmware |
NVSRAM |
CSM100 FC |
CSM100 SATA |
CSM200 |
FLA200 FC |
FLA300 FC |
FLC200 dSATA |
FLC200 iSATA |
Controller |
Expansion |
Sun StorageTek 6540 Firmware |
NOTE: Firmware shown as "controlled" are not publicly available and is only
provided on a case-by-case basis as deemed necessary by support services.
a Temporary fix for Sun Alert 102757 - 6140/6540
Exp Tray Firmware (IOM 9865) May Cause Loss of Access to Mulitple Disks.
Permanent fix in baseline 5.1 with IOM 9884.
b Some interim build before 06.19.23.10 may have
been released to some customers as temporary fix, these should be updated
to 5.1 baseline or later ASAP.
c Sun StorEdge 5000 NAS Gateway bug fix.
d 06.19.25.13/23 and 06.19.25.14/.24 were early access
releases of .16/26. Customers with this firmware should be updated to .16/26.
Note that .14 contains all fixes in .13 and supersedes it.
e (deleted)
f 7.10 firmware is an optional upgrade and
is not bundled in CAM 6.1.0 and 6.1.1.
(Refer to sun.com/download for Sun StorageTek 6000 Series Array Firmware Upgrade Utility.)
g (deleted)
h 7.10.25.10 firmware is now bundled in
CAM 6.1.2 but is still an optional upgrade. Separate utility still needed to
upgrade from 06.x to 07.10.25.10.
(Refer to sun.com/download for Sun StorageTek 6000 Series Array Firmware Upgrade Utility.)
i 7.15.11.11 firmware is bundled with
CAM 6.2.0.13. Separate utility still needed to upgrade from 06.x to 07.10,
then from 07.10 to 07.15 by CAM.
(Refer to sun.com/download for Sun StorageTek 6000 Series Array Firmware Upgrade Utility.)
j Fixes CR6757957 "Auto Code Sync feature failed
during controller replacement ... (6140, 6540, FLX380)"
k Temporary fix in NVSRAM for CR6704575 PFA issue.
l CAM 6.6.0.11 host types do not match array's
host region (CR6935284), affecting 2500, 6140, 6180, 6540, 6580/6780.
This may result in either new mappings selecting the wrong host region,
or user confused by the display and change existing mappings which was
correct, to become wrong. CAM 6.6.0.12 through patch 14147[456]-01 was
specifically released to resolve this bug.
|
Internal website for CAM supported array firmware matrix.
http://tsc-storage.us.oracle.com/products/CAM/matrix.html
This site is typically updated first before being edited for public consumption.
Attachments