Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1009853.1 : SL8500 - Foam Bumper Addition
PreviouslyPublishedAs 213518 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential for Partners and Oracle Support personnel
Applies to:Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later [Release: N/A and later]All Platforms Checked for relevance on 16-Mar-2011. GoalSL8500 Foam Bumper Addition.SolutionSteps to FollowSL8500 plastic corner assemblies have been inadvertently damaged on several occasions during field installation. SL8500 Foam Bumper Addition This damage is generally caused by falling tools or from other causes related to general movement within the Robotic Interface Module (RIM) during field assembly. Foam bumpers have been added to the RIM to provide protection from such damage during the installation process. The change was implemented on RIM S/N 386. Aluminum extrusions and copper conductor assemblies can and should be installed with the bumpers in place. It is important that these parts remain in place until just before the arrays are installed in the RIM. Once installed, the arrays adequately protect the corner plastic and corner copper from possible damage. Each foam bumper is held in place with a single tie wrap. Removal simply requires cutting the tie wrap and pulling the foam off of the corner assembly. After removal, ensure that no foam debris remains on the copper conductor assemblies. Foam bumpers have been added to the RIM to provide protection from such damage during the installation process (Figure 1). The change was implemented on RIM S/N 386. Aluminum extrusions and copper conductor assemblies can and should be installed with the bumpers in place (Figure 2). It is important that these parts remain in place until just before the arrays are installed in the RIM. Once installed, the arrays adequately protect the corner plastic and corner copper from possible damage. Each foam bumper is held in place with a single tie wrap (Figure 3). Removal simply requires cutting the tie wrap and pulling the foam off of the corner assembly. After removal, ensure that no foam debris remains on the copper conductor assemblies.
Figure 1: Bumpers installed in RIM
Figure 2: Ends available for aluminum extrusion and conductor installation
Figure 3: Tie wrap securing bumper SL8500 Modular Library System, SL8500 Foam Bumper Addition, Modular Library System, Foam Bumper Addition, CRCM Previously Published As 90866 Attachments This solution has no attachment |
||||||||||||
|