Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1009827.1 : L700/L180 - 9840FC Hard Addressing & Installation Configuration
PreviouslyPublishedAs 213484 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential information provided to Oracle and Partner Service Personnel
Applies to:Sun StorageTek 9840 Tape DriveSun StorageTek L180 Tape Library Sun StorageTek L700 Tape Library All Platforms Checked for relevance on 19-Jan-2011. GoalThere are some issues with the Oracle/Sun[TM] Leadville driver stack on Solaris[TM] 8 that require hard addressing to be used for all native FC-AL tape devices (including both the library and the 9840 drives). This will affect any/all CSE's who install Oracle-badged StorageTek L180/700 native fibre libraries with 9840 FC drives, and may affect other FC-AL installs into a Solaris 8 environment with the Leadville driver stack.SolutionSUN L700/L180 w/9840fc Hard Addressing & Installation Config.
Oracle is OEMing 9840 fibre channel drives and L180/700 libraries (with native fibre attach).
Configuration:
There are some issues with the Sun Leadville driver stack on Solaris 8 that require hard addressing to be used for all native FC-AL tape devices (including both the library and the 9840 drives). This will affect any/all CSE's who install Sun-badged StorageTek L180/700 native fibre libraries with 9840 FC drives, and may affect other FC-AL installs into a Solaris 8 environment with the Leadville driver stack.
Note:
Hard addressing is documented in the following Manuals: - 9840/T9940 Tape Drive Installation Manual, Chapter- 7 Drive Configuration, section "Fibre Channel Configuration Menu", Table 7-1. Menu Table--Fibre Channel Configuration #-95879 - L180 Tape Library Installation Manual, Chapter- 3 Library Configuration, section "Choosing Library Configuration Options", subsection "Port 0 Address" #-95896 - L700 Tape Library Installation Manual, Chapter- 4 Configuring the Library, section "Operator Panel Entry", subsection "Setting the Library Fibre Channel Port 0 Address" #-95843 Oracle Supplied Configuration Information Oracle is recommending the following HBAs: QLogic 2200 (Amber), QLogic
2202 (Crystal) Q: Current driver level of Leadville driver? Q: Current Patch level SUN recommends for Sol 8 installs or jumbo
patch? Q:What default settings would SUN recommend/support for HBA if any? Q: What fcaw setting/config options ? Q: For phase 2 - what bridge or bridges is Sun supporting? Q: What firmware level of Bridge? Q: What config options does Sun recommend? Q: does Sun have a Preferred Default Address that they are using ?
or are we still free to use the next open address ? Product Sun StorageTek L700 Tape Library Sun StorageTek L180 Tape Library Sun StorageTek T9840 Tape Drive Sun StorageTek L700 Tape Library, L700, L180, T9840, CRCM Previously Published As 90636 Attachments This solution has no attachment |
||||||||||||
|