Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1009823.1
Update Date:2009-04-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  1009823.1 :   Validating Sun StorEdge[TM] 6920 Pool Deletion  


Related Items
  • Sun Storage 6920 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
213476


Description
The purpose of this document is to provide basic steps for pool
deletion for the 6920 array, via the Browser User Interface(BUI) or
sscs Command Line Interface(CLI).

Content will be limited to a basic usage using the CLI or BUI interfaces
for deleting pools, and provide help with some usage failure scenarios
for this activity. Consider reviewing some of the following documents if you
are looking to perform actions beyond the scope of this document:



Steps to Follow
Validating Sun StorEdge[TM] 6920 Pool Deletion:

A. Validate if the Pool is in use

The pool should have a State of Not in Use. Reference <Document: 1007144.1> Validating Pool State and Details on a Sun StorEdge[TM] 6920

  • If the pool is in use, you must delete the volumes and vdisks before deleting the pool.
    Reference document <Document: 1005385.1> Validating Sun StorEdge[TM] 6920 Volume Deletion
    Reference document <Document: 1013077.1> Validating Sun StorEdge[TM] 6920 VDisk Deletion
  • If the pool is not in use, continue to Step B.

B. Basic Usage Using Browser or SSCS interfaces

SSCS

Pool deletion usage for sscs, can be reviewed in the Sun StorEdge 6920 System CLI Quick Reference Guide, Release 3.0. The sscs usage for basic pool deletion is as follows.

sscs delete pool <string[,string...]>

An example:

sscs delete pool joe-cli

This will delete the pool that is called joe-cli.

NOTE1: The Storage Domain is assumed to be DEFAULT when it is not specified by the -S switch in the usage

BUI

Pool Deletion steps for the BUI can be reviewed in Sun StorEdge 6920 System Administration Guide For the Browser Interface Management Software, Release 3.0 for help with other object deletion activities. Pool deletion for the BUI interface of the 6920 is completed as follows:

  1. Click on the Configuration Services or Common Array Manager Link.
  2. Click on the Pool Tab or Pool Menu Tree
  3. Click on the Pool Name for the Pool Details Page
  4. Click on the Delete Button
  5. Click OK to confirm the deletion

At this point the Pop-Up window will disappear, and the main browser screen will refresh, and a success or failure message will be displayed in the Pool Summary page. The pool will no longer be listed.

  • If you received a failure notification, continue to Step C.
  • If you received a success notification, you have validated that pool deletion is complete.

C. Deletion Failure.

Please review the following list for a failure message and corresponding action. Please follow the action that describes your symptom.

Browser
Message:
An error occurred. Please contact your system administrator

Action:
Please go to Step D.

Message:
None of the storage pools were deleted. The following errors occurred:<pool-name> - Item is in use

Action:
See Step A in this document

SSCS
Message:
Error: The operation failed.

Action:
Please go to Step D.

Message:
<pool-name>: Item is in use.

Action:
See Step A in this document

Message:
<pool-name>: not found

Action:
Check the storage domain specified, and make sure it matches the one for the pool. See Step B.

If a message is not listed, or an action above did not work, go to Step D.

D. Data Collection

Please collect the following information:

  • 6920 Solution Extract, reference document <Document: 1003756.1>  How to collect an extractor from a Sun StorEdge[TM] 6920 (2.x and 3.x)
  • The message given by SSCS or BUI(screen capture if possible)
  • The command used, if by SSCS
  • The following sscs output:

sscs list sdomain
sscs list volume
sscs list pool
sscs list pool <pool name>
sscs list vdisk

Once this information is collected, please contact Sun Support



Product
Sun StorageTek 6920 System
Sun StorageTek 6920 Maintenance Update 2
Sun StorageTek 6920 Maintenance Update 1

Internal Comments
Sun Support

This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

[email protected]



The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK


E. Validate that services are running properly on the SP


Reference document <Document: 1007129.1> Validating Services on a Sun StorEdge 6920 Service Processor



F. Perform health check of array


Reference document <Document: 1005447.1> Sun StorEdge[TM] 6920 Health Checklist



G. Escalate


Provide the following:



  • Description of what is not being displayed properly

  • Results of Step E.

  • Results of Step F.

  • Location of everything in Step D


6920, pool, delete, deletion, sscs, BUI, normalized, Audited
Previously Published As
90464

Change History
Date: 2007-09-27
User Name: 95826
Action: Approved
Comment: - verified metadata
- changed review date to : 2008-09-26
- checked normalized data
- checked for TM - none added
- checked audience : contract
Publishing
Version: 4
Date: 2007-09-27
User Name: 95826
Action: Add Comment
Comment: 89105 still pending (now on FR / Nita)
Version: 0
Date: 2007-09-27
User Name: 95826
Action: Accept
Comment:
Version: 0
Date: 2007-09-26
User Name: 39181
Action: Approved
Comment: 89105 has been submitted. Sending back to final review


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback