Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1009732.1 : Upgrading the Sun StorageTek[SM] 6320 and Online Disk firmware upgrades
PreviouslyPublishedAs 213376 Description When upgrading from older MIRE releases, the order that patches are installed is critical. Steps to Follow When upgrading a Sun StorageTek[SM] 6320 the order of patch upgrades is critical under certain conditions. The problem is that Online Disk firmware upgrades are not supported until Array firmware 3.2.0 (MIRE 1.3.3). Therefore, when upgrading from Array firmware 3.1.x (MIRE 1.2.x) to Array firmware 3.2.x (MIRE 1.3.x) the Patches must be applied in the following order in order: 1) Apply Service Processor Patches. 2) Apply Array firmware patches. 3) Apply Disk firmware patches. The Storade GUI, under: Manage -> Service -> Revision Maintenance -> Create Patch Report -> Select Patches will provide check boxes to allow the individual components to be selected. Be sure to install them in the order described above. Do not select the "Apply All Devices" button. Product Sun StorageTek 6120/6320 Controller Firmware 3.2 6320, Online, Disk Firmware, Upgrade, Storade, Patch Previously Published As 88250 Change History Date: 2007-02-02 User Name: 7058 Action: Approved Comment: Trademarked as needed. Enabled STM to clear up doc format. OK toi publish. Version: 3 Date: 2007-01-30 User Name: 7058 Action: Accept Comment: Version: 0 Date: 2007-01-30 User Name: 39181 Action: Approved Comment: Very useful doc for 6320 upgrades. If the patch order isn't followed then the customer could suffer downtime. Version: 0 Attachments This solution has no attachment |
||||||||||||
|