Solution Type Technical Instruction Sure Solution 1009561.1 : How to enable/configure Sun[TM] Remote System Control (RSC) Ethernet Access with Permanent IP Address
PreviouslyPublishedAs 213185 Description The Sun[TM] Remote System Control (RSC) card allows remote access to the system, independent of Solaris[TM], through the serial or Ethernet interface. The RSC is typicaly configured using the rsc-config script. If the Ethernet port was not configured at that time, the following procedure can be used to set up the Ethernet interface with a permanently assigned IP address. Steps to Follow Connect/login through the RSC's serial port, rsc> shownetwork RSC network configuration is: Ethernet is disabled. <-- current status is disabled rsc> show mail_enabled: false ip_mode: none <--------- valid values = {none | dhcp | config} ppp_enabled: false tpe_link_test: true serial_baud: 9600 serial_parity: none serial_stop: 1 serial_data: 8 customerinfo: ip_addr: 0.0.0.0 <---- not used if ip_mode is not "config" ip_netmask: 0.0.0.0 <---- not used if ip_mode is not "config" ip_gateway: 0.0.0.0 <---- not used if ip_mode is not "config" mailhost: mailuser: ppp_local_ip_addr: 0.0.0.0 ppp_remote_ip_addr: 0.0.0.0 hostname: escape_char: ~ rsc> set ip_mode config rsc> set ip_addr 10.12.9.95 rsc> set ip_netmask 255.255.255.0 rsc> set ip_gateway 10.12.9.1 rsc> set hostname myv490rsc <---- (optional but highly recommended in multiple system environments) rsc> show mail_enabled: false ip_mode: config <---------------- set but not yet active ppp_enabled: false tpe_link_test: true serial_baud: 9600 serial_parity: none serial_stop: 1 serial_data: 8 customerinfo: ip_addr: 10.12.9.95 ip_netmask: 255.255.255.0 ip_gateway: 10.12.9.1 mailhost: mailuser: ppp_local_ip_addr: 0.0.0.0 ppp_remote_ip_addr: 0.0.0.0 hostname: myv490rsc escape_char: ~ rsc> resetrsc Are you sure you want to reboot RSC (Yes/No)? yes User Requested RSC Shutdown Welcome to RSC bootmon v2.2.2 : : : rsc> shownetwork RSC network configuration is: IP Address: 10.12.9.95 Gateway address: 10.12.9.1 Netmask: 255.255.255.0 Ethernet address: 00:03:ba:4d:9e:89 Reference: Sun Remote System Control (RSC) 2.2 User's Guide (P/N 816-3314) contains information on setting "Ethernet Port Variables" under the section "Using RSC Command Shell" - "RSC Configuration Variables". Product Sun Fire V890 Server Sun Fire V880 Server Sun Fire V490 Server Sun Fire V480 Server Sun Fire 280R Server Sun Enterprise 250 Server Internal Comments For Internal Sun use only.
RSC Previously Published As 83655 Change History Date: 2009-11-25 User name: Dencho Kojucharov Action: Updated Comments: Currency check, audited by Dencho Kojucharov, Entry-Level SPARC Content Lead Attachments This solution has no attachment |
||||||||||||
|