Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1009021.1 : How To Configure the ALOM Notification Variables
PreviouslyPublishedAs 212441
Applies to:Sun Fire V210 ServerSun Fire V440 Server Sun Fire V240 Server - Version: Not Applicable and later [Release: N/A and later] Sun Netra 240 (AC) Server - Version: Not Applicable and later [Release: N/A and later] Sun Netra 210 Server - Version: Not Applicable and later [Release: N/A and later] All Platforms GoalDescriptionThis Technical Instruction will describe how to configure ALOM notification variables to send out email to specified recipients when alerts of a desired level take place. This procedure is accurate for ALOM versions 1.0 through current which is 1.5.x SolutionSteps to FollowHow To Configure the ALOM Notification Variables Configuring the ALOM Notification Variables will allow varying levels of To use this functionality, ALOM requires the NET MGT port to be configured and As in the NET MGT port configuration Article, the Notifications variable We will cover the method assuming a tip connection to the ALOM serial port 1) Use the "showsc" command to show the current config sc> showsc parameter value sc> setsc if_emailalerts true The above command enables the mail alerts to be sent sc> setsc mgt_mailhost 129.148.9.16 This (above) command sets the IP address of the mail server to which ALOM delivers the mail sc> setsc mgt_mailalert [email protected] 1 This (above) command sets who will be sent the email with the alerts and what level alerts sc> setsc mgt_mailalert [email protected] 3 This (above) command shows the configuration of an additional email address to sc> showsc This (above) command will show the configuration with the changes Advanced Lights Out Manager v1.0 parameter value To remove an email address from the configuration so that alerts are no sc> setsc mgt_mailalert [email protected] sc> showsc - shows that [email protected] is now removed Advanced Lights Out Manager v1.0 parameter value To demonstrate the event notification the system is powered down: sc> poweroff -y The following email was then received: From: [email protected] System Event Recorded By SC: HostID: "83295e2b" Event: "00040029" Time: "TUE SEP 16 17:39:22 2003" Customer Info: "No Entry" Hostname: "abcd" SC IP Address: "129.148.173.27" Message: "Host system has shut down." 2) The same configuration can be done through the use of the Solaris based #scadm set if_emailalerts true #scadm set mgt_mailhost 129.148.9.16 #scadm set mgt_mailalert [email protected] 1 #scadm show if_network="true" Product Sun Fire V210 Server Sun Fire V440 Server Internal Comments Internal Link for
Technical Instruction Document 1004884.1 alom, net mgt, v210, v240, v440, sys_eventlevel, mgt_mailalert Previously Published As 72123 Change History Date: 2010-12-21 User Name: Ian Macdonald Action: Updated Change History Date: 2007-04-04 User Name: 31620 Action: Approved Comment: Verified Metadata - ok Verified Keywords - ok Verified still correct for audience - currently set to contract Audience left at contract as per FvF at http://kmo.central/howto/content/voyager-contributor-standards.html Checked review date - added 1yr to make it 2008-03-28 Checked for TM - ok as presented Publishing under the current publication rules of 18 Apr 2005: Version: 10 Date: 2007-04-02 User Name: 31620 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|