Solution Type Technical Instruction Sure Solution 1008986.1 : Updating Firmware and BIOS on a Sun Fire[TM] V60x/V65x Server
PreviouslyPublishedAs 212401 Description How to update Firmware and BIOS on a Sun Fire[TM] V60x/V65x Server Steps to Follow How to update the Firmware and BIOS on a Sun Fire V60x and V65x Server: Note: You must first create the 3 bootable diskettes needed to update the firmware (FRU/SDR, BMC and BIOS) before proceeding. See how to create these diskettes from a particular system (i.e. windows, linux, X86) at the end of this procedure. 1. Power off or reboot the Sun Fire V60x or V65x server system. 2. Insert the FRU/SDR update diskette into the server and power on the system. The system automatically boots to the FRU/SDR diskette and a banner displays identifying the platform and software. Note: See how to create this "FRU/SDR" diskette from a particular system (i.e. windows, linux, X86) at the end of this procedure. 3. After a menu of options appears that prompts you to select the function you want to perform, Select Option 1, Update FRUs and the SD repository. 4. You are prompted to indicate whether you want to update serial number and asset tag information. Select N for No if you don't want to update this information (the existing serial number and asset tag will remain unchanged). Select Y for Yes if you want to update any of this information. Follow the prompts to continue the update. The FRU/SDR update continues and the system returns to the command prompt when completed. 5. Remove the FRU/SDR update diskette and power off the Sun Fire V60x or V65x server. 6. Insert the BMC update diskette into the server and power on the system. The system automatically boots to the BMC update diskette and a banner display identifying the platform and software. Note: See how to create this "BMC" diskette from a particular system (i.e. windows, linux, X86) at the end of this procedure. 7. Press any key to proceed with the update when prompted. The update continues and the system returns to the command prompt when done. 8. Remove the BMC update diskette and power off the Sun Fire V60x or V65x server. 9. Insert the BIOS update diskette into the server and power on the system. The system automatically boots to the BIOS update diskette and a banner displays identifying the platform and software. Note: See how to create this "BIOS" diskette from a particular system (i.e. windows, linux, X86) at the end of this procedure. 10. Press any key to proceed with the update when prompted. The update continues and the system returns to the command prompt when completed, then it automatically reboots. Note: Watch the system carefully so that you are aware of when the update is complete and the system begins to automatically reboot. As described in the next step, you must remove the floppy diskette from drive A before the system reboots. 11. When the update is completed, remove the floppy diskette from drive A. The system will automatically reboot when the update is completed. 12. Press the F2 key to select SETUP as soon as the option appears on the screen. 13. Once you are in the main page of the SETUP menu, use the arrow key to select the Server menu. 14. In the Server screen, select the System Management option, then press Enter. The newly updated BIOS and other firmware revisions are displayed as shown here: BIOS version: [SWV25.86B.1191.P08] BMC Firmware Revision: [0119] SDR Revision: [5.5.5] 15. If the BIOS and firmware revisions display correctly, proceed to Step 16. If any of the firmware components do not show the correct revision, do the following: a. Make a note of the incorrect revisions. b. Turn off the server. c. Unplug the AC power cord for about 30 seconds and then plug it back in. d. Power on the server. e. Return to the beginning of this section and reinstall the updates for the BIOS or firmware components that do not display the correct revision. 16. Press the F9 key to select default settings. 17. Select Yes and press the Enter key. 18. Press the F10 key to select Save and Exit. 19. Select Yes and press the Enter key. 20. The system automatically reboots. The BIOS and firmware update procedures are completed. ====================================================================== Creating BIOS and Firmware Update Diskettes ====================================================================== (Solaris[TM] X86 Users) Create BIOS and Firmware Update Diskettes (Solaris X86 Users) To download the BIOS and firmware updates to diskettes using a Solaris" x86 system: 1. Log into the Solaris[TM] system as superuser. 2. Turn off the volmgt daemon by typing: # /etc/init.d/volmgt stop 3. Download the Sun Fire V60x and V65x FRU/SDR image file (fsdr555.img) and the sum file (fsdr555.sum) onto the Solaris system. download from: http://wwws.sun.com/software/download/products/3f26a272.html (You will need to register to do this. Takes just a moment) or see the V65 home page in the Sun[TM] System Handbook. 4. Verify that the .sum file matches the fsdr555.img file contents: a. At the Solaris prompt, type: # sum fsdr555.img, followed by # cat fsdr555.sum b. Compare the output of the sum command with the contents of the fsdr555.sum file to make sure that they match. 5. Place a formatted 1.44MB diskette into drive A. 6. At the Solaris command prompt, type: # dd if=fsr555.img of=/dev/fd0 7. The file will automatically extract the update onto the floppy drive. 8. When the extraction is complete, remove and label the diskette Sun Fire V60/V65 FRU/SDR version 5.5.5. 9. Download the Sun Fire V60x and V65x BMC image file (bmc119.img) and the sum file (bmc119.sum) onto the Solaris system. download from: http://wwws.sun.com/software/download/products/3f26a272.html (You will need to register to do this. Takes just a moment) or see the V65 home page in the Sun System Handbook. 10. Verify that the .sum file matches the bmc119.img file contents: a. At the Solaris prompt, type: # sum bmc119.img, followed by # cat bmc119.sum b. Compare the output of the sum command with the contents of the bmc119.sum file to make sure that they match. 11. Insert a formatted 1.44MB diskette into drive A. 12. At the Solaris command prompt, type: # dd if=bmc119.img of=/dev/fd0 The file automatically extracts the update onto the floppy drive. 13. After the extraction is complete, remove and label the diskette Sun Fire V60/V65 BMC version 1.19. 14. Download the Sun Fire V60x and V65x BIOS image file (bios1191.img) and the sum file (bios1191.sum) onto the Solaris system. download from: http://wwws.sun.com/software/download/products/3f26a272.html (You will need to register to do this. Takes just a moment) or see the V65 home page in the Sun System Handbook. 15. Verify that the .sum file matches the bios1191.img file contents: a. At the Solaris prompt, type: # sum bios1191.img, followed by # cat bios1191.sum b. Compare the output of the sum command with the contents of the bios1191.sum file to make sure that they match. 16. Insert a formatted 1.44MB diskette into drive A. ----------------------------------------------------------------------- (Linux Users) Create BIOS and Firmware Update Diskettes (Linux Users) To download the BIOS and firmware updates to diskettes using a Linux system: 1. Download the Sun Fire V60x and V65x FRU/SDR image file (fsdr555.img) and the md5 file (fsdr555.md5) onto a Linux system. download from: http://wwws.sun.com/software/download/products/3f26a272.html (You will need to register to do this. Takes just a moment) or see the V65 home page in the Sun System Handbook. 2. Verify that the md5sum of the file matches the fsdr555.md5 file contents: a. At the Linux command prompt, type: # md5sum fsdr555.img, followed by # cat fsdr555.md5 b. Compare the output of the md5sum command with the contents of the fsdr555.md5 file to make sure that they match. 3. Insert a formatted 1.44MB diskette into drive A. 4. At the Linux command prompt, type: # dd if=fsdr555.img of=/dev/fd0 The file will automatically extract the update onto the floppy drive. 5. The extraction is complete, remove and label the diskette Sun Fire V60/V65 FRU/SDR version 5.5.5. 6. Download the Sun Fire V60x and V65x BMC image file (bmc119.img) and the md5 file (bmc119.md5) onto a Linux system. download from: http://wwws.sun.com/software/download/products/3f26a272.html (You will need to register to do this. Takes just a moment) or see the V65 home page in the Sun System Handbook. 7. Verify that the md5sum of the file matches the bmc119.md5 file contents: a. At the Linux command prompt, type: # md5sum bmc119.img, followed by # cat bmc119.md5 b. Compare the output of the md5sum command with the contents of bmc119.md5 to make sure that they match. 8. Insert a formatted 1.44MB diskette into drive A. 9. At the Linux command prompt, type: # dd if=bmc119.img of=/dev/fd0 The file will automatically extract the update onto the floppy drive. 10. After the extraction is complete, remove and label the diskette Sun Fire V60/V65 BMC version 1.19. 11. Download the Sun Fire V60x and V65x BIOS image file (bios1191.img) and the md5 file (bios1191.md5) onto a Linux system. download from: http://wwws.sun.com/software/download/products/3f26a272.html (You will need to register to do this. Takes just a moment) or see the V65 home page in the Sun System Handbook. 12. Verify that the md5sum of the file matches the bios1191.md5 file contents: a. At the Linux prompt, type: # md5sum bios1191.img, followed by # cat bios1191.md5 b. Compare the output of the md5sum command with the contents of bios1191.md5 to make sure that they match. 13. Insert a formatted 1.44MB diskette into drive A. 14. At the Linux command prompt, type: # dd if=bios1191.img of=/dev/fd0 The file will automatically extract the update onto the floppy drive. 15. After the extraction is complete, remove and label the diskette Sun Fire V60/V65 BIOS 1191. 16. Proceed to Update the Firmware and BIOS above. ----------------------------------------------------------------------- (Windows Users) Create BIOS and Firmware Update Diskettes (Windows Users) To download the BIOS and firmware updates to diskettes using a Windows system: 1. Download the Sun Fire V60x and V65x FRU/SDR self-extracting file (FSDR555.EXE) onto a Windows system. download from: http://wwws.sun.com/software/download/products/3f26a272.html (You will need to register to do this. Takes just a moment) or see the V65 home page in the Sun System Handbook. 2. Insert a formatted 1.44MB diskette into drive A. 3. Double click on the FSDR555.EXE file and follow the instructions on the screen. The file will automatically extract the update onto the floppy drive. 4. After the extraction has completed, remove and label the diskette Sun Fire V60/V65 FRU/SDR version 5.5.5. 5. Download the Sun Fire V60x and V65x BMC self-extracting file (BMC119.EXE) onto the Windows system. download from: http://wwws.sun.com/software/download/products/3f26a272.html (You will need to register to do this. Takes just a moment) or see the V65 home page in the Sun System Handbook. 6. Insert a formatted 1.44MB diskette into drive A. 7. Double click on the BMC119.EXE file and follow the instructions on the screen. The file will automatically extract the update onto the floppy drive. 8. After extraction is completed, remove and label the diskette Sun Fire V60/V65 BMC version 1.19. 9. Download the Sun Fire V60x and V65x BIOS self extracting file (BIOS1191.EXE) onto a Windows system. download from: http://wwws.sun.com/software/download/products/3f26a272.html (You will need to register to do this. Takes just a moment) or see the V65 home page in the Sun System Handbook. 10. Insert a formatted 1.44MB diskette into drive A. 11. Double click on the BIOS1191.EXE file and follow the instructions on the screen. The file will automatically extract the update onto the floppy drive. 12. After the extraction is completed, remove and label the diskette Sun Fire V60/V65 BIOS version 1191. 13. Proceed to Update the Firmware and BIOS above. Product Sun Fire V65x Server Sun Fire V60x Server V60, V65, update firmware, BIOS Previously Published As 71204 Change History Date: 2006-01-27 User Name: 7058 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT Version: 0 Date: 2006-01-27 User Name: 7058 Action: Update Started Comment: SSH AUDIT Version: 0 Product_uuid 079e9bbc-0ee3-11d7-8c50-f1061905b56f|Sun Fire V65x Server 03728cec-0ee3-11d7-9be8-dd41f651e0a3|Sun Fire V60x Server Attachments This solution has no attachment |
||||||||||||
|