Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1008936.1 : StorEdge L20/L40/L60 - Firmware Upgrade Procedure
PreviouslyPublishedAs 212296
Applies to:Sun Storage L20 (StorEdge-OEM) Tape Library - Version: Not ApplicableSun Storage L40 (StorEdge-OEM) Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun Storage L60 (OEM) Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 2-Feb-2011. GoalThis document describes how to upgrade the firmware of the StorEdge L20/L40/L60 Tape Libraries.SolutionSteps to FollowFrom time to time it is required to upgrade the library firmware of these libraries, especially if any hardware such as the picker assembly has been swapped. Since the inclusion of the Remote Management Card into these systems, this has made the task really straightforward. The library may be connected to the customer's local LAN but access can also be achieved by attaching a crossover cable between a laptop and the libraries RJ45 ethernet port. If the tape library does not have the network interface or RJ45 port configured, following the procedure in Technical Instruction < Document: 1010650.1> 'Configuring Ethernet port for Firmware Upgrade or Remote Management' to setup the interface. NOTE: The procedure outlined below can be used to downgrade library firmware as well as upgrade if there is a suspicion that someone has jumped to the latest revision instead of doing things 'by the book'. NOTE: Before proceeding note the following: Library and drive's SCSI target addresses (Op panel: Main, 1. library info 3. View config, more, 1. SCSI IDs). NOTE: Also note barcode character length. Valid values are 6, 7,or 8. (Main , 3. Admin 3. Change config, more, 3 Other config options, more, 1. Barcode character length). If the customer is using Netbackup you need to check that the value is set to the same afterwards. Bug ID 4934287 - 1.55 firmware and Netbackup PATCHES Library patch. (Can only be loaded via the network port). 111972-05 (or later) contains the robotics firmware for the Sun StorEdge L20/L40/L60 tape libraries. Drive patches. (Loaded over SCSI using tload). The drives are separate devices so firmware upgrades can be done independently of library upgrades. 116328-01 (or later) DLT7000 firmware for L20/40/60 112068-02 (or later) DLT8000 firmware for L20/40/60 113359-01 (or later) LTO-1 firmware for L20/40/60 -o0o- The procedure is as follows: # ftp The Sun StorEdge L20/L40/L60 service password cannot be used to perform the firmware upgrade, you must use the Administration password ... If the administration password has not been set on the library, you will need to set this prior to performing the firmware upgrade. If your laptop is also used on SWAN don't forget to disable the Netscape proxy server when doing a crossover connection directly to the Library. Be aware of FIN #I0758 when replacing FRU's the only way to check individual components in the library is by generating a report using the above Web interface. Be Aware of Sun Alert #28490 : DLT8000 tape drives may Experience Data Corruption During Read or Write Operations. It would be good to check drive firmware for rev 59 when checking library firmware. Additional Internal Info.... This info. is not to be released to the customer... You may well find that the customer has not set either the admin or service password and will have no idea what the default passwords are. The service code is 42311324 The admin code is for customer admin use. Units are shipped with admin password switched off. If setting an admin password Sun engineers generally use a default of 12341234 If the admin password is lost it can be reset by a Sun engineer in the service menu. (change configuration, password). The service password must not be given to the customer. Written By Alice Soteriou ([email protected]) L20, L40, L60, firmware, upgrade Previously Published As 73214 Change History Date: 2006-08-21 User Name: 97961 Action: Approved Comment: Publishing. No further edits required. Version: 7 Date: 2006-08-21 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2006-08-21 User Name: 116530 Action: Approved Comment: looks good Version: 0 Product_uuid 2abb82de-0a18-11d6-8be8-e69160731f04|Sun StorageTek L40 Tape Library 2abee4e2-0a18-11d6-959c-b09e2f8f1b57|Sun StorageTek L60 Tape Library 2ab7e5fc-0a18-11d6-8193-b157d4a5d57c|Sun StorageTek L20 Tape Library Attachments This solution has no attachment |
||||||||||||
|