Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1008798.1 : Fast Data Access MMU Miss Error on Netra[TM] X1
PreviouslyPublishedAs 212083 Description Fast Data Access MMU Miss Error on Netra[TM] X1 Steps to Follow A Fast Data Access MMU Miss error on a Netra X1 can indicate that there are no users added to LOM. Here is what is needed to be typed at the LOM prompt in order to correct this error: At the lom> prompt useradd <name> The username can be up to 8 characters long, begins with an alphabetic character, and contains at least one lowercase alphabetic character. You can use any of the following in the user name: Alphanumeric, Period(.), underscore (_), Hyphen (-)
userperm <enter> userpassword <type password> logout <login> break <give ok> prompt> Product System Management NEBS-Certified Servers Netra X1 Server Internal Comments The following is strictly for the use of Sun employees: Created by Kori Bowers useradd, Netra Previously Published As 50060 Change History The following products in the product statement are not specific products, but folders: System Management NEBS-Certified Servers In order to publish they either need to be eliminated or amended so that they are specific products in the swordfish database. "MIGRATION CLEANUP" Attachments This solution has no attachment |
||||||||||||
|