Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1008519.1 : SVA/VSM - Define Functional Devices
PreviouslyPublishedAs 211645
Applies to:Sun StorageTek V2X SVA Disk System - Version: Not Applicable to Not Applicable [Release: N/A to N/A]Sun StorageTek VSM System - Version: 4 to 5C [Release: 4.0 to 5.0] All Platforms GoalAdditional devices cannot be defined on the SVA/VSM. If the IXFP/SVAA software is being used to define volumes, then various error messages including SIB1168E, SIB1132E, and/or SIB1157E may be detected. If the operator panel is being used to define volumes, then FSC 3E9A may be noted.SolutionEXPLANATION: The subsystem has reached the maximum number of cylinders for all functional devices or the maximum number of functional devices.Either of the following limits is a subsystem restriction: * The maximum number of functional devices (excluding 3390-9) is 1024. * The maximum number of total cylinders for all functional devices is product This restriction is due to the total maximum number of cylinders for all devices defined on the subsystem. SOLUTION: Define the functional device types in appropriate combinations without exceeding the limits. The device type sets the number of cylinders for each functional device: * 3390-1 1113 * 3390-2 2226 * 3390-3 3339 * 3390-9 10017 * 3380-J 885 * 3380-KE 1770 * 3380-K 2655 K.W. - 10/06/00 - CREATED. Product Sun StorageTek 9500 Shared Virtual Array (SVA) Sun StorageTek FlexLine V2X2/V2X4f Shared Virtual Array Disk System Sun StorageTek 960 Shared Virtual Array (SVA) Sun StorageTek 9393 Shared Virtual Array (SVA) Sun StorageTek 9200 Virtual Disk Storage Sun StorageTek 9500 Shared Virtual Array (SVA), 9200, 9500, V960, 9393, V2X, SVA217, Iceberg, CRCM Previously Published As 91089 Change History Date: 2007-10-08 User Name: 71396 Action: Approved Comment: Performed final review of article. Updated trademarking. Publishing. Version: 3 Date: 2007-10-02 User Name: 14889 Action: Approved Comment: This document is part of the CRC Migration effort and does not require the standard technical review process. Version: 0 Date: 2007-10-02 User Name: 25646 Action: Approved Comment: This document is part of the CRC Migration effort and does not require the standard technical review process. Version: 0 Date: 2007-10-02 User Name: 25646 Action: Created Comment: Version: 0 Product_uuid 79f0dfcb-5220-4cb6-b862-797a64691127|Sun StorageTek 9500 Shared Virtual Array (SVA) 51016f5a-cff0-11da-a933-080020a9ed93|Sun StorageTek FlexLine V2X2/V2X4f Shared Virtual Array Disk System 3d59c434-6c87-11dc-932b-080020a9ed93|Sun StorageTek 960 Shared Virtual Array (SVA) 167d0bc1-61d6-4f3f-953e-debde9b8afc6|Sun StorageTek 9393 Shared Virtual Array (SVA) 9730dd0c-9c16-48dc-b7bf-05154e72e08c|Sun StorageTek 9200 Virtual Disk Storage Attachments This solution has no attachment |
||||||||||||
|