Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1008519.1
Update Date:2011-06-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1008519.1 :   SVA/VSM - Define Functional Devices  


Related Items
  • Sun StorageTek VSM System
  •  
  • Sun StorageTek V2X SVA Disk System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  
  • GCS>Sun Microsystems>Storage - Disk>Datacenter Disk - Other
  •  

PreviouslyPublishedAs
211645


Applies to:

Sun StorageTek V2X SVA Disk System - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun StorageTek VSM System - Version: 4 to 5C   [Release: 4.0 to 5.0]
All Platforms

Goal

Additional devices cannot be defined on the SVA/VSM. If the IXFP/SVAA software is being used to define volumes, then various error messages including SIB1168E, SIB1132E, and/or SIB1157E may be detected. If the operator panel is being used to define volumes, then FSC 3E9A may be noted.

Solution

EXPLANATION: The subsystem has reached the maximum number of cylinders for all functional devices or the maximum number of functional devices.

Either of the following limits is a subsystem restriction:

* The maximum number of functional devices (excluding 3390-9) is 1024.
* The maximum number of total cylinders for all functional devices is product 
  model and microcode dependent. Refer to the SVA/VSM Planning manual for the product in question for details.

This restriction is due to the total maximum number of cylinders for all devices defined on the subsystem.

SOLUTION: Define the functional device types in appropriate combinations without exceeding the limits.

The device type sets the number of cylinders for each functional device:

* 3390-1 1113
* 3390-2 2226
* 3390-3 3339
* 3390-9 10017
* 3380-J 885
* 3380-KE 1770
* 3380-K 2655 

K.W. - 10/06/00 - CREATED.



Product
Sun StorageTek 9500 Shared Virtual Array (SVA)
Sun StorageTek FlexLine V2X2/V2X4f Shared Virtual Array Disk System
Sun StorageTek 960 Shared Virtual Array (SVA)
Sun StorageTek 9393 Shared Virtual Array (SVA)
Sun StorageTek 9200 Virtual Disk Storage

Sun StorageTek 9500 Shared Virtual Array (SVA), 9200, 9500, V960, 9393, V2X, SVA217, Iceberg, CRCM
Previously Published As
91089

Change History
Date: 2007-10-08
User Name: 71396
Action: Approved
Comment: Performed final review of article.

Updated trademarking.

Publishing.
Version: 3
Date: 2007-10-02
User Name: 14889
Action: Approved
Comment: This document is part of the CRC Migration effort and does not require the standard technical review process.
Version: 0
Date: 2007-10-02
User Name: 25646
Action: Approved
Comment: This document is part of the CRC Migration effort and does not require the standard technical review process.
Version: 0
Date: 2007-10-02
User Name: 25646
Action: Created
Comment:
Version: 0
Product_uuid
79f0dfcb-5220-4cb6-b862-797a64691127|Sun StorageTek 9500 Shared Virtual Array (SVA)
51016f5a-cff0-11da-a933-080020a9ed93|Sun StorageTek FlexLine V2X2/V2X4f Shared Virtual Array Disk System
3d59c434-6c87-11dc-932b-080020a9ed93|Sun StorageTek 960 Shared Virtual Array (SVA)
167d0bc1-61d6-4f3f-953e-debde9b8afc6|Sun StorageTek 9393 Shared Virtual Array (SVA)
9730dd0c-9c16-48dc-b7bf-05154e72e08c|Sun StorageTek 9200 Virtual Disk Storage

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.