Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1008494.1
Update Date:2009-04-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1008494.1 :   Validating Sun StorEdge[TM] 6920 VDisk Modification  


Related Items
  • Sun Storage 6920 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
211613


Description
The purpose of this document is to provide basic steps for vdisk modification for the Sun StorEdge[TM] 6920 System, via the Browser User Interface(BUI) or sscs Command Line Interface(CLI).


Content will be limited to a basic usage using the CLI or BUI interfaces for modifying vdisks, and provide help with some usage failure scenarios for this activity. Consider reviewing some of the following documents when looking to perform actions beyond the scope of this document:

Steps to Follow
Validating Sun StorEdge[TM] 6920 VDisk Modification

A. Basic Usage of Browser or SSCS Interfaces for Changing the Name and Description

SSCS

modify -P|--new-pool <string> [-p|--pool <string>] vdisk <string>

This CLI will change:

  • The storage pool

NOTE1: The Storage Domain is assumed to be DEFAULT when it is not specified by the -S switch in the usage

BUI

  1. Click on the Configuration Services or Common Array Manager(3.2.0.38) Link.
  2. Click on the Virtual Disk Tab or Virtual Disk Menu Tree
  3. Click on the Virtual Disk Name that you wish to modify
  4. Select the new pool from the Storage Pool pulldown menu
  5. Click the Save button
  • If you received a failure notification, continue to Step B.
  • If you received a success notification, you have validated that volume modification is complete.

B. Creation Failure.

Please review the following table for a failure message and corresponding action. Please follow the action that describes your symptom.

BUI
Message:
An error occurred. Please contact your system administrator

Action:
Please go to Step C.

SSCS
Message:
The specified VDisk is not compatible with the requested Storage Pool

Action:
Use sscs list pool <pool name> to compare the old and new pool attributes.

Message:
<pool_name>: The resource was not found.

Action:
Make sure the pool exists and the name is correct(sscs list pool)

Message:
<domain>: The resource was not found.

Action:
Check the spelling of the domain name, and make sure it exists(sscs list sdomain)

Message:
Error: The operation failed.

Action:
Please go to Step C.

If a message is not listed, or an action above did not work, go to Step C.

C. Data Collection

Please collect the following information:

  • 6920 Solution Extract, reference document <Document: 1003756.1>  How to collect an extractor from a Sun StorEdge[TM] 6920 (2.x and 3.x)
  • The message given by SSCS or BUI(screen capture if possible)
  • The command used, if by SSCS
  • The following sscs output:

sscs list sdomain
sscs list pool
sscs list pool <pool name>
sscs list vdisk
sscs list vdisk <vdisk name>

NOTE 2: Screen captures of the summary page for each object could be used, as well, for BUI related creations.

Once this information is collected, please contact Sun Support



Product
Sun StorageTek 6920 System
Sun StorageTek 6920 Maintenance Update 2
Sun StorageTek 6920 Maintenance Update 1

Internal Comments
Sun Support

This document contains normalized content and is managed by the the Domain Lead(s) of the
respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

[email protected]

The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK.


D. Validate command provided


Validate command provided against examples in the Sun StorEdge 6920 System CLI Quick Reference Guide, Release 3.0.

Ensure that options are valid based on the usage available in reference guide.



E.
error occurred


If the customer reports:



An error occurred. Please contact your system administrator


OR



Error: The operation failed.


Validate the services on the Service Processor. Reference document <Document: 1007129.1> 



F. Perform health check of array


Reference document <Document: 1005447.1> Sun StorEdge[TM] 6920 Health Checklist



G. Escalate


Provide the following:



  • Description of what is not being displayed properly

  • Results of Step D.

  • Results of Step E.

  • Results of Step F.

  • Location of everything in Step C


and escalate to your next level of support.


modify, configure, vdisk, 6920, normalized, change, pool, audited
Previously Published As
90571

Change History
Date: 2007-09-28
User Name: 7058
Action: Approved
Comment: OK to publish.
Version: 4
Date: 2007-09-28
User Name: 7058
Action: Reassign
Comment: permision to accept into my queue for publish.
Version: 0



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.