Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1008494.1 : Validating Sun StorEdge[TM] 6920 VDisk Modification
PreviouslyPublishedAs 211613 Description The purpose of this document is to provide basic steps for vdisk modification for the Sun StorEdge[TM] 6920 System, via the Browser User Interface(BUI) or sscs Command Line Interface(CLI). Content will be limited to a basic usage using the CLI or BUI interfaces for modifying vdisks, and provide help with some usage failure scenarios for this activity. Consider reviewing some of the following documents when looking to perform actions beyond the scope of this document:
Steps to Follow Validating Sun StorEdge[TM] 6920 VDisk Modification A. Basic Usage of Browser or SSCS Interfaces for Changing the Name and Description SSCS modify -P|--new-pool <string> [-p|--pool <string>] vdisk <string> This CLI will change:
NOTE1: The Storage Domain is assumed to be DEFAULT when it is not specified by the -S switch in the usage BUI
B. Creation Failure. Please review the following table for a failure message and corresponding action. Please follow the action that describes your symptom.
BUI
Action:
SSCS
Action: Message: Action: Message: Action: Message: Action: If a message is not listed, or an action above did not work, go to Step C. C. Data Collection Please collect the following information:
sscs list sdomain NOTE 2: Screen captures of the summary page for each object could be used, as well, for BUI related creations. Once this information is collected, please contact Sun Support Product Sun StorageTek 6920 System Sun StorageTek 6920 Maintenance Update 2 Sun StorageTek 6920 Maintenance Update 1 Internal Comments Sun Support This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: [email protected] The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK.
Validate command provided against examples in the Sun StorEdge 6920 System CLI Quick Reference Guide, Release 3.0.
If the customer reports:
OR
Validate the services on the Service Processor. Reference document <Document: 1007129.1>
Reference document <Document: 1005447.1> Sun StorEdge[TM] 6920 Health Checklist
Provide the following:
and escalate to your next level of support. modify, configure, vdisk, 6920, normalized, change, pool, audited Previously Published As 90571 Change History Date: 2007-09-28 User Name: 7058 Action: Approved Comment: OK to publish. Version: 4 Date: 2007-09-28 User Name: 7058 Action: Reassign Comment: permision to accept into my queue for publish. Version: 0 Attachments This solution has no attachment |
||||||||||||
|