Solution Type Technical Instruction Sure Solution 1007974.1 : VxVM: Restoration method from SNAPDONE plex to mirror volume
PreviouslyPublishedAs 210996 Description This document shows how to recover a mirrored volume, when both sides of a mirror have had problems, and the only valid remaining plex is the snapshot plex. Steps to Follow Example and Steps to Follow ExampleIn the following example, VxVM is used to create mirrored volumes from Logical A vxprint of the diskgroup dg0 shows that there are 2 plexes on these volumes, Disk group: dg0 TY NAME ASSOC KSTATE LENGTH PLOFFS STATE TUTIL0 PUTIL0 dg dg0 dg0 - - - - - - dm c2t1d0s2 - - - - NODEVICE - - dm c3t0d0s2 c3t0d0s2 - 1000624128 - - - - dm c4t0d0s2 - - - - NODEVICE - - v vol11 fsgen ENABLED 166748160 - ACTIVE - - pl vol11-01 vol11 DISABLED 166756352 - NODEVICE - - sd c2t1d0s2-01 vol11-01 DISABLED 166756352 0 NODEVICE - - pl vol11-02 vol11 DISABLED 166756352 - NODEVICE - - sd c4t0d0s2-01 vol11-02 DISABLED 166756352 0 NODEVICE - - pl vol11-04 vol11 ENABLED 166756352 - SNAPDONE - - sd c3t0d0s2-01 vol11-04 ENABLED 166756352 0 - - - v vol12 fsgen ENABLED 166748160 - ACTIVE - - pl vol12-01 vol12 DISABLED 166756352 - NODEVICE - - sd c4t0d0s2-02 vol12-01 DISABLED 166756352 0 NODEVICE - - pl vol12-02 vol12 DISABLED 166756352 - NODEVICE - - sd c2t1d0s2-03 vol12-02 DISABLED 166756352 0 NODEVICE - - pl vol12-04 vol12 ENABLED 166756352 - SNAPDONE - - sd c3t0d0s2-02 vol12-04 ENABLED 166756352 0 - - - Steps To recover:1. Check and resolve the hardware issue that caused the Volume Manager problem. Do not attempt recovery until you are certain that the hardware issue has been resolved. 2. Change the status of snapshot plex from SNAPDONE to ACTIVE using the vxplex command shown below: # vxplex [-g diskgroup] convert state=ACTIVE plex # vxplex convert state=ACTIVE vol11-04 # vxplex convert state=ACTIVE vol12-04 3. Check that the status has indeed changed, by doing another vxprint Disk group: dg0 TY NAME ASSOC KSTATE LENGTH PLOFFS STATE TUTIL0 PUTIL0 dg dg0 dg0 - - - - - - dm c2t1d0s2 - - - - NODEVICE - - dm c3t0d0s2 c3t0d0s2 - 1000624128 - - - - dm c4t0d0s2 - - - - NODEVICE - - v vol11 fsgen ENABLED 166748160 - ACTIVE - - pl vol11-01 vol11 DISABLED 166756352 - NODEVICE - - sd c2t1d0s2-01 vol11-01 DISABLED 166756352 0 NODEVICE - - pl vol11-02 vol11 DISABLED 166756352 - NODEVICE - - sd c4t0d0s2-01 vol11-02 DISABLED 166756352 0 NODEVICE - - pl vol11-04 vol11 ENABLED 166756352 - ACTIVE - - sd c3t0d0s2-01 vol11-04 ENABLED 166756352 0 - - - v vol12 fsgen ENABLED 166748160 - ACTIVE - - pl vol12-01 vol12 DISABLED 166756352 - NODEVICE - - sd c4t0d0s2-02 vol12-01 DISABLED 166756352 0 NODEVICE - - pl vol12-02 vol12 DISABLED 166756352 - NODEVICE - - sd c2t1d0s2-03 vol12-02 DISABLED 166756352 0 NODEVICE - - pl vol12-04 vol12 ENABLED 166756352 - ACTIVE - - sd c3t0d0s2-02 vol12-04 ENABLED 166756352 0 - - - 4. Since Volume Manager sees the original subdisks as state NODEVICE, use vxdiskadm option #5 to replace failed or removed disk. This will reattach the plex to the volume and initiate a resync from the remaining good plex. 5. Reset the original state of SNAPDONE on the plexes made ACTIVE in step 2 using the following vxplex command: vxplex [-g diskgroup] convert state=SNAPDONE plex # vxplex convert state=SNAPDONE vol11-04 # vxplex convert state=SNAPDONE vol12-04 Product VERITAS Volume Manager 3.0.2 Software Sun StorageTek T3 Array Sun StorageTek T3+ Array VxVM, Volume Manager, snapdone, plex Previously Published As 82303 Change History Date: 2005-08-04 User Name: 18392 Action: Approved Comment: Added product names, product nouns, trademarking, STM, did some re-wording and formatting for clarity and readability. Version: 3 Date: 2005-08-03 User Name: 18392 Action: Accept Comment: Version: 0 Date: 2005-08-03 User Name: 119902 Action: Approved Comment: I have reviewed this document, made many necessary changes and submit it for final reveiw. Version: 0 Product_uuid a99f8f3a-2bd5-11d6-87a3-e467d9c55f5e|VERITAS Volume Manager 3.0.2 Software 2a6d7d50-0a18-11d6-8e0b-f0bd33b24928|Sun StorageTek T3 Array 2a714b10-0a18-11d6-86e2-d56b387d4fbf|Sun StorageTek T3+ Array Attachments This solution has no attachment |
||||||||||||
|