Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1007958.1 : When Sun StorEdge [TM] T3 (T3B) 2.x firmware is upgraded to 3.1,the sys parameter "rd_ahead" is always turned off
PreviouslyPublishedAs 210977 Description When T3B 2.x firmware is upgraded,the sys parameter "rd_ahead" is turned off regardless of the previous setting. Steps to Follow The T3B firmware was 2.x and rd_ahead parameter was set on. The following table describes the effect on the value of the rd_ahead parameter after a firmware upgrade: ------------------------------- From To "rd_ahead" ------------------------------- 2.1.4 2.1.6 on 2.1.6 3.1.2 off 2.1.6 3.1.4 off 2.1.6 3.1.6 off 3.1.2 3.1.6 on 3.1.4 3.1.6 on ------------------------------- *The previous setting was on. The test results show this phenomenon doesn't happen when the firmware is upgraded from 3.x to above version. So, this problem doesn't affect 6120 arrays. ============================================== t3:/:<1>ver T3B Release 2.01.06 2003/11/06 14:59:41 (129.158.60.67) Copyright (C) 1997-2001 Sun Microsystems, Inc. All Rights Reserved. t3:/:<2>sys list blocksize : 64k cache : auto mirror : auto mp_support : rw naca : off rd_ahead : on <==== check the parameter recon_rate : med sys memsize : 128 MBytes cache memsize : 1024 MBytes enable_volslice : off fc_topology : auto ============================================== After upgrading firmware to 3.1 revision,the "rd_ahead" parameter is turned off regardless of the previous setting. ============================================== t3:/:<1>ver T3B Release 3.1.6 Thu Feb 3 16:39:28 PST 2005 (129.158.60.67) Copyright (C) 1997-2003 Sun Microsystems, Inc. All Rights Reserved. t3d2u7:/:<2>sys list controller : 2.0 blocksize : 64k cache : auto mirror : auto mp_support : rw naca : off rd_ahead : off <==== check the parameter recon_rate : med sys memsize : 128 MBytes cache memsize : 1024 MBytes enable_volslice : off fc_topology : auto fc_speed : 1Gb disk_scrubber : on ondg : befit ============================================== The rd_ahead parameter must be manually set to "on" again if this setting is required. t3:/:<1>sys rd_ahead on Product Sun StorageTek T3+/6X20 Controller Firmware 3.1 Sun StorageTek T3+ Array T3+, T3B, firmware, rd_ahead, 3.1, 2.x, upgrade Previously Published As 81835 Change History Date: 2005-06-15 User Name: 31620 Action: Approved Comment: Verified Metadata - Verified Keywords - Verified still correct for audience - currently set to contract Audience left at contract as per FvF http://kmo.central/howto/FvF.html Checked review date - currently set to 2006-06-07 Checked for TM - needed Sun StorEdge [TM] T3 adding to correct the title. Attachments This solution has no attachment |
||||||||||||
|