Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1007876.1 : Solaris[TM] Operating System: Two ways to gather disk info for a failed disk.
PreviouslyPublishedAs 210876 Description This document shows how to gather disk info like "disk model", and/or "disk vendor", for a failed disk that is marked as <drive not available: formatting> in the format program. Steps to Follow Solaris[TM] Operating System: Two ways to gather disk info for a failed disk. Description
SENA DISK STATUS SLOT FRONT DISKS (Node WWN) REAR DISKS (Node WWN) 0 On (O.K.) 200000203XXXX967 On (O.K.) 200000203XXXX994 1 On (O.K.) 200000203XXXXdd8 On (O.K.) 200000203XXXX7e0 2 On (O.K.) 200000203XXXX1a9 On (O.K.) 200000203XXXX507 3 On (O.K.) 200000203XXXX59e On (O.K.) 200000203XXXXee5 4 On (O.K.) 20000011cXXXX84a On (O.K.) 200000203XXXXe83 5 On (O.K.) 20000004cXXXXaa1 On (O.K.) 200000203XXXXba5 6 On (O.K.) 200000203XXXX324 On (O.K.) 200000203XXXXff0 7 On (O.K.) 200000203XXXXff1 On (O.K.) 20000004cXXXX9b1 8 On (O.K.) 200000203XXXX167 On (O.K.) 200000203XXXX62b 9 On (Faulted) On (O.K.) 200000203XXXX820 10 On (O.K.) 200000203XXXX02b On (O.K.) 200000203XXXX379
Two Possible Paths of Action1) With iostat -En In this case: c3t9d0 Soft Errors: 0 Hard Errors: 12 Transport Errors: 19 Vendor: SEAGATE Product: ST39103FCSUN9.0G Revision: 114B Serial No: 0032XXXX32 Size: 9.06GB <9055065600 bytes> 2) Using other inquiry comand at Operating System level. From the /var/adm/messages file: Dec 29 08:42:20 dr-ressys scsi: [ID 107833 kern.warning] WARNING: /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w210000203XXXX8f3,0 (ssd65): Dec 29 08:42:20 dr-ressys transport rejected (-2) ssd driver instance # is 65. Looking in the /etc/path_to_inst file will verify that the ssd instance # 65 is assigned to the disk with WWN 210000203XXXX8f3: "/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w210000203XXXX8f3,0" 65 "ssd" Looking for instance #65 from prtconf -v comand output: ssd, instance #65 Driver properties: name <pm-components> length <30> value 'NAME=spindle-motor' + '0=off' + '1=on' name <pm-hardware-state> length <21> value 'needs-suspend-resume' name <ddi-failfast-supported> length <0> -- <no value>. name <ddi-kernel-ioctl> length <0> -- <no value>. Hardware properties: name <inquiry-revision-id> length <5> value '114B' name <inquiry-product-id> length <17> value 'ST39103FCSUN9.0G' name <inquiry-vendor-id> length <8> value 'SEAGATE' name <inquiry-device-type> length <4> value <0x00000000>. name <lun> length <4> value <0x00000000>. name <lip-count> length <4> value <0x00000026>. name <port-wwn> length <8> value <0x210000203XXXX8f3>. name <node-wwn> length <8> value <0x200000203XXXX8f3>. It can be confirmed, that thedisk model is ST39103FC, size is 9.0 GB, etc.. NOTE: This information will not be available if the host has been rebooted since Product Solaris 8 Operating System Sun StorageTek A5200 Array Solaris 9 Operating System Solaris 7 Operating System Solaris 2.6 Operating System Solaris 10 Operating System disk, faulted, format, prtconf, iostat Previously Published As 83518 Change History Date: 2009-11-26 User Name: 98025 Action: Updated Comment: Still valid, Audited/updated 11/26/09 - Mahendra Prabhu, OS Content Team Date: 2006-01-09 User Name: 18392 Action: Approved Comment: Added product name to title as per standards. Added trademarking, changed audience from Free to Contract, as per Fee vs. Free requirements, did grammar and spelling corrections, changed serial numbers, WWN's, did some re-wording and formatting for clarity and readability. Attachments This solution has no attachment |
||||||||||||
|