This document shows how to gather disk info like "disk model", and/or "disk
vendor", for a failed disk that is marked as <drive not available: formatting>
in the format program.


Steps to Follow
Solaris[TM] Operating System: Two ways to gather disk info for a failed disk.

Description

  • Environment: A Sun StorEdge[TM] A5200 Array, with disk f,9 faulted:
  • Extract from luxadm command display:
                                    SENA
DISK STATUS
SLOT   FRONT DISKS    (Node WWN)          REAR DISKS    (Node WWN)
0      On (O.K.)      200000203XXXX967    On (O.K.)     200000203XXXX994
1      On (O.K.)      200000203XXXXdd8    On (O.K.)     200000203XXXX7e0
2      On (O.K.)      200000203XXXX1a9    On (O.K.)     200000203XXXX507
3      On (O.K.)      200000203XXXX59e    On (O.K.)     200000203XXXXee5
4      On (O.K.)      20000011cXXXX84a    On (O.K.)     200000203XXXXe83
5      On (O.K.)      20000004cXXXXaa1    On (O.K.)     200000203XXXXba5
6      On (O.K.)      200000203XXXX324    On (O.K.)     200000203XXXXff0
7      On (O.K.)      200000203XXXXff1    On (O.K.)     20000004cXXXX9b1
8      On (O.K.)      200000203XXXX167    On (O.K.)     200000203XXXX62b
9      On (Faulted)                       On (O.K.)     200000203XXXX820
10     On (O.K.)      200000203XXXX02b    On (O.K.)     200000203XXXX379
  • The front of the array shows a faulted disk in slot 9.
  • From the format command:
    31. c3t9d0 <drive not available: formatting>
    /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w210000203XXXX8f3,0
  • format-inquiry does not work.
  • Explorer diskinfo does not work.
  • prtvtoc /dev/rdsk/c#t#d#s2 does not work.
  • Disk is not mirrored, and does not belong to any VXVM/SVM volume.
  • Disk sizes are mixed on the box.

Two Possible Paths of Action

1) With iostat -En

  In this case:
  c3t9d0    Soft Errors: 0 Hard Errors: 12 Transport Errors: 19
Vendor: SEAGATE  Product: ST39103FCSUN9.0G Revision: 114B Serial No: 0032XXXX32
Size: 9.06GB <9055065600 bytes>

2) Using other inquiry comand at Operating System level.

   From the /var/adm/messages file:
    Dec 29 08:42:20 dr-ressys scsi: [ID 107833 kern.warning] WARNING:
/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w210000203XXXX8f3,0 (ssd65):
Dec 29 08:42:20 dr-ressys       transport rejected (-2)
    ssd driver instance # is 65.
    Looking in the /etc/path_to_inst file will verify that the ssd instance
# 65 is assigned to the disk with WWN 210000203XXXX8f3:

"/sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w210000203XXXX8f3,0" 65 "ssd"

    Looking for instance #65 from prtconf -v comand output:
           ssd, instance #65
Driver properties:
name <pm-components> length <30>
value 'NAME=spindle-motor' + '0=off' + '1=on'
name <pm-hardware-state> length <21>
value 'needs-suspend-resume'
name <ddi-failfast-supported> length <0> -- <no value>.
name <ddi-kernel-ioctl> length <0> -- <no value>.
Hardware properties:
name <inquiry-revision-id> length <5>
value '114B'
name <inquiry-product-id> length <17>
value 'ST39103FCSUN9.0G'
name <inquiry-vendor-id> length <8>
value 'SEAGATE'
name <inquiry-device-type> length <4>
value <0x00000000>.
name <lun> length <4>
value <0x00000000>.
name <lip-count> length <4>
value <0x00000026>.
name <port-wwn> length <8>
value <0x210000203XXXX8f3>.
name <node-wwn> length <8>
value <0x200000203XXXX8f3>.

It can be confirmed, that thedisk model is ST39103FC, size is 9.0 GB, etc..

NOTE: This information will not be available if the host has been rebooted since
the disk failed.



Product
Solaris 8 Operating System
Sun StorageTek A5200 Array
Solaris 9 Operating System
Solaris 7 Operating System
Solaris 2.6 Operating System
Solaris 10 Operating System

disk, faulted, format, prtconf, iostat
Previously Published As
83518

Change History
Date: 2009-11-26
User Name: 98025
Action: Updated
Comment: Still valid, Audited/updated 11/26/09 - Mahendra Prabhu, OS Content Team

Date: 2006-01-09
User Name: 18392
Action: Approved
Comment: Added product name to title as per standards. Added trademarking, changed audience from Free to Contract, as per Fee vs. Free requirements, did grammar and spelling corrections, changed serial numbers, WWN's, did some re-wording and formatting for clarity and readability.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback