Solution  1007868.1 :   Sun StorEdge [TM] 5310 NAS Appliance generates write-cache disabled emails  


Related Items
  • Sun Storage 5310 NAS Appliance
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Network Attached Storage
  •  

PreviouslyPublishedAs
210868


Description
If the Administrator has configured the 5310 to generate email notification, during the course of normal operation of the SE5310, the administrator may see
email messages generated by the 5300EU indicating that there is a critical error and that write-cache has been disabled. These messages are NOT always generated.  They will only be seen when the 5300EU undergoes a battery test cycle AND the test cycle indicates that a battery recharge is required. See the following for further details:


Steps to Follow
The first email notification indicates that write-cache has been disabled
for controller 1 and 0:
From: 5310@your_company.com
Date: December 9, 2005 2:06:27 AM EST
To: 5310_admin@your_company.com
Subject: Critical: Write-cache is disabled on Ctlr 1 and 0
SYSTEM NOTIFICATION
System           : StorEdge Model 5310C NAS
Version          : 5310 NAS 4.10 M1 (Build 2)
Customer         : Acme Widgets
Contact Person   : 5310_admin
Contact Phone    : 555 555 1235
Location         : (not configured)
Serial Number SW : SE5310C2005062818
Serial Number HW : FG52720019
Host             : 5310 [192.168.1.100]
URL              : http://5310.your_company.com
Subsystem        : RAID
Severity         : Critical
Time Stamp       : Fri Dec  9 02:06:27 2005
IP address of remote log file server: None
Problem:
Ctlr 1 Battery Pack Charging
Course of Action:
Contact Technical Support.
Shortly thereafter, another message is generated indicating that the
write-cache has been enabled for controller 1 and 0:
From: 5310@your_company.com
Date: December 9, 2005 2:07:18 AM EST
To: 5310_admin@your_company.com
Subject: Critical: Write-cache is enabled on Ctlr 1 and 0
SYSTEM NOTIFICATION
System           : StorEdge Model 5310C NAS
Version          : 5310 NAS 4.10 M1 (Build 2)
Customer         : Acme Widgets
Contact Person   : 5310_admin
Contact Phone    : 555 555 1235
Location         : (not configured)
Serial Number SW : SE5310C2005062818
Serial Number HW : FG52720019
Host             : 5310 [192.168.1.100]
URL              : http://5310.your_company.com
Subsystem        : RAID
Severity         : Critical
Time Stamp       : Fri Dec  9 02:07:18 2005
IP address of remote log file server: None
Problem:
Ctlr 1 Battery Pack Power Normal
Course of Action:
--
Every 25 hours, the 5300EU initiates a battery test cycle. This pair of
email notifications indicates that during the battery test cycle, the battery
in controller 1 is undergoing a recharge cycle. This 25 hour timeframe is not
changable by the user.
The Battery Management Controller utilizes an  intelligent charger
integrated circuit (IC). This means that the battery charger is utra-fast
and microprocessor  controlled, as opposed to a manual battery charger.
The charger IC is configured as a pulsed current charger with two charging
modes:
High current charge mode:   The charging current is regulated at 0.72
Amps until the cell voltage rises to 4.94 V.   This mode is typically
seen when a new or discharged battery is installed in the array.
Low current pulsed charge mode:   The charging current is removed
until the battery voltage falls to 4.66 V. Charging current is then
restored and regulated at 0.72 Amps until the battery voltage once
again rises to 4.94 V. This cycle is repeated indefinitely.  This
is the typical operating mode of the charger circuit.
When the voltage in the battery drops below the 4.66 V threshold, write-cache
is disabled, the first message is generated and the Battery Management Controller activates the low current pulsed charge mode.  When the battery voltage rises above 4.94 V, the charging is complete, charging current is removed, write-cache is enabled and the second message is generated.
If there are write-cache disabled/enabled messages and recharge cycles, reported with every battery test cycle (every 25 hours) the controller battery may require replacement.


Product
Sun StorageTek 5310 NAS Appliance

5310, 5300EU, battery, write-cache disable, Battery Pack Power Normal, Battery Pack Charging
Previously Published As
83412

Change History
Date: 2005-12-20
User Name: 31620
Action: Approved
Comment: Verified Metadata - ok
Verified Keywords - ok
Verified still correct for audience - was free, now set to contract
Audience changed to contract as per FvF http://kmo.central/howto/FvF.html
Checked review date - currently set to 2006-12-14
Checked for TM - added one for 5310
Publishing under the current publication rules of 18 Apr 2005:
Version: 4
Date: 2005-12-17
User Name: 31620
Action: Accept
Comment:
Version: 0
Date: 2005-12-16
User Name: 100761
Action: Approved
Comment: Good Doc.
Version: 0
Date: 2005-12-15
User Name: 100761
Action: Accept
Comment:
Version: 0
Date: 2005-12-15
User Name: 119902
Action: Approved
Comment: Made requested updates, please review for techincal accuracy
Version: 0
Date: 2005-12-14
User Name: 44570
Action: Rejected
Comment: You say they may see this email. This is true or will they see the email. If it is a will, you should say that.

At the end you suggest that if you see this too often you should replace the batteries. I know there will be questions about what is too often. Suggest you either give some sort of guidelines or declare how often is normal to see this email. Every 25 hours? Is there a way to disable it short of disabling email?
Version: 0
Date: 2005-12-14
User Name: 44570
Action: Accept
Comment:
Version: 0
Date: 2005-12-14
User Name: 119902
Action: Approved
Comment: Please review for technical accuracy
Version: 0
Date: 2005-12-14
User Name: 119902
Action: Created
Comment:
Version: 0
Product_uuid
63654ce5-f88d-11d8-ab63-080020a9ed93|Sun StorageTek 5310 NAS Appliance

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback