Description
This document describes a way to selectively clear settings of the Sun Fire[TM] system controller and specifies which settings may be cleared in this way.

This method allows clearing of erroneous settings for some parameters without clearing the whole configuration.



Steps to Follow
There are many situations when a system administrator or support engineer needs to clear a parameter setting on the system controller.

The most straightforward way to do this it to use setdefaults command but this command will clear the entire configuration of the system controller and it is not always convenient. There is a way to clear selective settings without clearing the whole configuration.

In order to clear particular parameter of the system controller type a dash (-) as a response for a relevant question of setupplatform or setupdomain command.

kremlin-sc0:SC> showplatform -p network
The system controller is configured to be on a network.
Network settings: static
Hostname: kremlin-sc0
IP Address: 129.145.23.230
Netmask: 255.255.255.0
Gateway: 129.145.23.250
DNS Domain: example.org
Primary DNS Server: 129.145.23.50
Secondary DNS Server: 129.145.24.50
Connection type: telnet
Idle connection timeout : No timeout
kremlin-sc0:SC>
kremlin-sc0:SC> setupplatform -p network
Network Configuration
---------------------
Is the system controller on a network? [yes]:
Use DHCP or static network settings? [static]:
Hostname [kremlin-sc0]:
IP Address [129.145.23.230]:
Netmask [255.255.255.0]:
Gateway [129.145.23.250]:
DNS Domain [example.org]: -
Primary DNS Server [129.145.23.50]: -
Secondary DNS Server [129.145.24.50]: -
To enable remote access to the system controller, select "ssh" or "telnet".
Connection type (ssh, telnet, none) [telnet]: 
Rebooting the SC is required for changes in the above network settings to take  effect.
Idle connection timeout (in minutes; 0 means no timeout) [0]:  
kremlin-sc0:SC>
kremlin-sc0:SC> showplatform -p network
The system controller is configured to be on a network.
Network settings: static
Hostname: kremlin-sc0
IP Address: 129.145.23.230
Netmask: 255.255.255.0
Gateway: 129.145.23.250
DNS Domain:
Primary DNS Server:
Secondary DNS Server:
Connection type: telnet
Idle connection timeout : No timeout
kremlin-sc0:SC>

For system controllers of Sun Fire[TM] 3800-6800/E4900/E6900 servers the following parameters may be cleared selectively in this way:

  • Default Gateway
  • DNS Domain
  • Primary DNS Server
  • Secondary DNS Server
  • Log Host
  • Log Facility
  • SNTP Server
  • Logical IP
  • SNMP Platform Description
  • SNMP Platform Contact
  • SNMP Platform Location
  • SNMP Domain Description
  • SNMP Domain Contact
  • SNMP Trap Host
  • SNMP Public Community String
  • SNMP Private Community String
  • Hardware ACLs


Product
Sun Fire E6900 Server
Sun Fire E4900 Server
Sun Fire 6800 Server
Sun Fire 4810 Server
Sun Fire 4800 Server
Sun Fire 3800 Server

clear, settings, system controller, SC
Previously Published As
82652

Change History
Date: 2006-01-25
User Name: 31620
Action: Modify Creator
Comment: Victor has become a permanent employee of Sun, so the leading C in C146290 need removing .
Victor logged Service Desk ticket on this:

Ticket : 4251961
Submit Time : Jan 26 2006 12:01AM
Priority : 3
Status : Scheduling In Progress
Short Desc : my documents and my drafts lists are empty after becoming an employee - Admin Modify of Creator to Victor Latushkin (146290)
Version: 0
Date: 2005-09-20
User Name: 71396
Action: Approved
Comment: Performed final review of article.

No changes required.

Publishing.