Solution Type Technical Instruction Sure Solution 1007570.1 : HARDWARE: What to do if Sun[TM] Remote System Control (RSC) is configured and the password is forgotten
PreviouslyPublishedAs 210475
Applies to:Sun Fire V480 ServerSun Fire V490 Server Sun Fire V880 Server Sun Fire V890 Server Sun Enterprise 250 Server All Platforms ***Checked for relevance on 10-05-2011*** GoalDescriptionThis document describes the procedure to regain control of the RSC card if the username or password have been forgotten and the RSC card is set as the console. SolutionSteps to Follow:If the OBP is earlier than 4.15.x, then follow the steps listed below. If the OBP is 4.15.0 or later, then the keyswitch can be put in the "diag" position to enable "service mode". Then, the system can be power cycled or reset remotely to force output to ttya. See SRDB (Symptoms and Resolutions) Document 1009167.1 for more details on this. STEP 1: If root can login into system remotely then proceed to Step 2. If root cannot access system remotely and RSC is currently the active However, because RSC is configured we would need * Method 1: Notes: * Method 2: When the system is at the ok prompt, manually set the input-device With both methods, when the console is on ttya, boot the OS and log in STEP 2: a. Execute the following 3 Solaris commands in order to create a new RSC
user with full permissions: /usr/platform/`uname -i`/rsc/rscadm useradd Note: You may need to delete an RSC user if there are already 4 existing RSC users defined. To check what users exist use: /usr/platform/`uname -i`/rsc/rscadm usershow To remove a user: /usr/platform/`uname -i`/rsc/rscadm userdel b. Reboot the RSC card. c. Log into RSC using the login and password created in Step 2a. d. If you used method 1 in step 1 above, you will have to reboot the e. If you used method 2 in step 1 above, then you will have to return It is advisable to check that the login created in step 2a works prior to re-enabling the RSC console. Internal Comments Audited/updated 11/19/09 - [email protected], Entry Level SPARC Content Team Member Authors:
Symptom Resolution RSC, password, passwords, forgotten, rscadm, HARDWARE Previously Published As 47745 Change History Date: 2007-11-15 User Name: 97961 Action: Approved Comment: Publishing. No further edits required. Version: 12 Attachments This solution has no attachment |
||||||||||||
|