Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1007406.1
Update Date:2009-09-28
Keywords:

Solution Type  Technical Instruction Sure

Solution  1007406.1 :   How can to tell if a mezzanine board is installed on a Sun Enterprise[TM] 10000 system board?  


Related Items
  • Sun Enterprise 10000 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
210233


Steps to Follow
To determine whether there is an IO/Mezzanine board installed without
taking the Sun Enterprise 10000 (E10000) down, run;

# redx -c
eepr io sb#

This will return the serial number on the board. If it does not find the
board it will return code=0.

Product
Sun Enterprise 10000 Server

Internal Comments
New queue text: TeleRequest/SYSTEM/ER-SW/SSID:<10502929>
------- Updated by TELEUSER 23-Jun-99 09:19 US/Pacific--------

WHAT:
------- Updated by LBYERS 23-Jun-99 10:19 US/Mountain--------
how can cu tell if mezzanine board is installed on the system board

Determine the type of Hardware Phone Support needed and select the
appropriate
link:

HARDWARE-Installation-grp2
HARDWARE-Diagnostics-grp2

E10K
PLATINUM/GOLD ALL HES 69446-01 50017-01 69446-01


New queue text: p/lt/how can cu determine if mezzanine board is installed
on the system board
------- Updated by LBYERS 23-Jun-99 10:21 US/Mountain--------
------- Updated by LBYERS 23-Jun-99 10:22 US/Mountain--------
------- Updated by JANNATPO 23-Jun-99 10:31 US/Mountain--------
Cu wants to know if there is a IO/Mezzanine without taking the system down.

Did a

redx -c
eepr io sb#
This will return the serial number on the board. If it does not find
it
it will come back with code=0....
bye.
------- Updated by JANNATPO 23-Jun-99 10:45 US/Mountain--------
Previously Published As
19650

Change History
Date: 2003-10-14
User Name: 81292
Action: Approved
Comment: Added trademarks and verified doc 22158 covers other information. This document is still OK. Ready to publish
Version: 0
Date: 2003-10-12
User Name: 116819
Action: Approved
Comment: still valid
Version: 0
Date: 2003-10-07
User Name: 6196
Action: Approved
Comment: I think that this article could be a duplicate of 22158. Maybe a merger of the two is the best route.
Version: 0
Date: 2003-09-29
User Name: 6196
Action: Updated
Comment:
Version: 0
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : No owner
comment : Previously was SOtool SO: 4013522
date : Jun 24, 1999
Version: 0
Product_uuid
29ddef46-0a18-11d6-92de-ae47474f0f6c|Sun Enterprise 10000 Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback