Solution  1007335.1 :   Target conflicts between StorEdge[TM] D1000 and other devices or peripherals  


Related Items
  • Sun Storage D1000 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
210121


Steps to Follow

If customers are using D1000 arrays on their systems, and try to add additional device entries to the /kernel/drv/sd.conf file, it is necessary to ensure that certain target numbers remain unused. Situations have arisen where people try to attach EMC arrays or other third-party hardware to Sun servers, and have been given specific targets to enter in sd.conf. In the case of Symmetrix arrays, up to 128 LUNs per target are possible, and are configured at the array level initially. If target 14 or 15 is attempted on systems that run D1000's, various types of mischief could result. The entries generally appear as follows (output has been truncated for current purposes):

name="sd" class="scsi" target=15 lun=0;

name="sd" class="scsi" target=15 lun=1;

name="sd" class="scsi" target=15 lun=2;

name="sd" class="scsi" target=15 lun=3;

name="sd" class="scsi" target=15 lun=4;

name="sd" class="scsi" target=15 lun=5;

One thing that may indicate a conflict is that the system will hang on boot. A boot -v or -rv will provide information about where the process is bogging down. Shutting the server down, removing the offending entries in the sd.conf file, and rebooting should fix this. One may find supporting documentation on page 4 of P/N 805-4866 , the Sun StorEdge A1000/D1000 Product Note: "Caution: Do not assign SCSI ID numbers 14 or 15 to any device. Both SCSI ID 14 and 15 are reserved for the GEM chips (SCSI enclosure sensing chips) on the controller board."

This obviates the need for alternate SCSI targets to be assigned to the device that was originally intended for addition. Thus, reconfiguring the Symmetrix or other array/device is necessary, and new entries subsequently written to the sd.conf file.



Product
Sun StorageTek D1000 Array

Internal Comments







Previously Published As
25864

Change History
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : Richard Khleif
comment : No comment
date : Apr 6, 2001



updated by : Adam Kittell
comment : No comment
date : Apr 6, 2001



updated by : Adam Kittell
comment : No comment
date : Apr 6, 2001



updated by : George Bolduc
comment : Looks good.
date : Apr 6, 2001



updated by : Richard Khleif
comment : Article created.
date : Mar 2, 2001
Version: 0
Product_uuid
2a753f90-0a18-11d6-96d0-f5e96014c515|Sun StorageTek D1000 Array

Attachments

This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback