Solution Type Technical Instruction Sure Solution 1007158.1 : Validating Replication Set Modification for a Sun Storedge[TM] 6920
PreviouslyPublishedAs 209862 Description Validating Replication Set Modification for a Sun Storedge[TM] 6920 The purpose of this document is to provide basic steps for Remote Replication Content will be limited to a basic usage using the CLI or BUI interfaces
Consider reviewing some of the following documents if you are looking to perform actions beyond the scope of this document:
NOTE: Some operations apply only for the primary array, some only for the secondary array, and some for both. These will be annotated in BOLD. Steps to Follow Repsets, Autosyncs, Snapshots, & Arrays A. Suspend a Repset This is to be executed on the PRIMARY site SSCS sscs modify -c repset <repset_name> EX: sscs modify -c repset repset3/1 BUI
B. Resuming a Repset This is to be executed on the PRIMARY site SSCS sscs modify -z repset <repset_name> EX: sscs modify -z repset repset3/1 BUI
The following Procedures require that the set be in a state of Suspended C. Enable Autosync Autosync is an operation that automatically resumes a set SSCS modify [-s|--auto-sync <enable|disable>] repset <repset_name>
EX:
BUI
D. Enable/Disable Taking a Snapshot of Secondary Volume, When the Primary Volume is Snapshotted This does not depend on the replication set state. When a Primary volume has a snapshot taken, the secondary volume will take a snapshot at the same time, ensuring that both sides have the same point in time data. This requires This can be executed on either array, but only applies when the set role is secondary for that site. Snapshot for the Volume must be created manually. Reference document <Document: 1011356.1> : Validating Sun Storedge[TM] 6920 Snapshot Creation SSCS sscs modify [-x <enable|disable>] repset <repset_name>
EX:
BUI
E. Enable/Disable Taking a Snapshot of the Secondary Volume, when Set is Resumed This can be executed on either array, but only applies when the set role is secondary for that site. Snapshot for the Volume must be created manually. Reference document <Document: 1011356.1> : Validating Sun Storedge[TM] 6920 Snapshot Creation SSCS modify [-p <enable|disable>] repset <repset_name>
EX:
BUI
F. Change Set Mode from Async to Sync This can be executed on either array, but only applies when the set role is primary for that site. SSCS modify -m sync repset <repset_name>
EX:
G. Change Set Mode from Sync to Async This can be executed on either array, but only applies when the set role is primary for that site. SSCS modify -m async -q <queue volume pool> -u [block|suspend] -k [# blocks in queue for queue full] -t [# IOs in queue for queue full] repset <repset_name> EX: sscs modify -m async -q my-async-queue-pool -u block -k 0 -t 0 repset myprimaryvol/1
Note: Specifying the blocks and IO's on queue as zero(0), allows the full size of the queue volume, to be used. If a queue full condition is hit, the repset will either block new IO's or place the set automatically into a Suspend state.
H. Changing the Set Role for the local array This can be executed on either array, and needs to be changed on BOTH arrays, prior to resuming the set. SSCS modify [-r <primary|secondary>] repset <repset_name>
EX:
BUI
I. Change Replication Priority This can be executed on either array, but only applies when the set role is primary for that site. SSCS modify [-R <low|medium|high>] repset <repset_name> EX: sscs modify -R high repset repset3/1 BUI
J. Creation Failure. Please review the following table for a failure message and corresponding action. Please follow the action that describes your symptom. BUI Message: Action: SSCS Message: Action: Message: Action: Message: Action: If a message is not listed, or an action above did not work, go to Step K. K. Data Collection Please collect the following information:
sscs list sdomain Once this information is collected, please contact Sun Support Product Sun StorageTek 6920 System Sun StorageTek 6920 Maintenance Update 2 Sun StorageTek 6920 Maintenance Update 1 Internal Comments Validate command and perform health check of array This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: [email protected]
Validate command provided against examples in the Sun StorEdge 6920 System CLI Quick Reference Guide, Release 3.0.
If the customer reports:
OR
Validate the services on the Service Processor. Reference <Document: 1007129.1>
Reference <Document: 1005447.1> : Sun StorEdge[TM] 6920 Health Checklist
Provide the following:
modify, configure, remote replication, replication sets, 6920, rename, normalized, audited Previously Published As 90756 Change History Date: 2007-09-28 User Name: 7058 Action: Approved Comment: OK to publish. Version: 3 Date: 2007-09-26 User Name: 7058 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|