Asset ID: |
1-71-1007142.1 |
Update Date: | 2011-05-06 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1007142.1
:
Sun StorageTek[TM] Common Array Manager: How to Save an Array Configuration for Duplication or Restoration
Related Items |
- Sun Storage 6540 Array
- Sun Storage Flexline 280 Array
- Sun Storage 2510 Array
- Sun Storage 2530 Array
- Sun Storage 2540 Array
- Sun Storage 6580 Array
- Sun Storage 6130 Array
- Sun Storage 6140 Array
- Sun Storage 6780 Array
- Sun Storage Flexline 240 Array
- Sun Storage Common Array Manager (CAM)
- Sun Storage Flexline 380 Array
- Sun Storage 6180 Array
|
Related Categories |
- GCS>Sun Microsystems>Storage Software>Modular Disk Device Software
|
PreviouslyPublishedAs
209841
Applies to:
Sun Storage 2510 Array
Sun Storage 2530 Array
Sun Storage 2540 Array
Sun Storage 6130 Array
Sun Storage 6140 Array
All Platforms
***Checked for relevance on 06-May-2011***
Goal
This document explains how to export an array configuration or a storage
profile for the purposes of duplicating the configuration to another
array, or for the case where the array configuration was reset.
NOTE: This is not a document that describes how to recover the array configuration without overwriting data. This process is designed to be applied to an array where the configuration has either been reset, or has not been configured at all.
Solution
The export and import of the configuration is handled by the sscs CLI.
Solaris: /opt/SUNWstkcam/bin/
Linux: /opt/sun/cam/bin/
Windows: C:\Program Files\Sun\Common Array Manager\bin
1. Export the array configuration in XML:
sscs export array <array-name> > /tmp/array-config.xml
Example:
# sscs export array 2530-LCA > /tmp/array-config.xml
2. Export the array profile configuration into an XML file:
sscs export -a <array-name> profile > /tmp/array-profile.xml
Example:
# sscs export -a 2530-LCA profile > /tmp/array-profile.xml
3. Import an Array Configuration:
Import the configuration of an array saved as an XML file using the export array command and apply the configuration to the specified array.
This overwrites the existing configuration on this array, destroying any data!!!
sscs import -x xml-location array <array-name>
Example:
# sscs import -x array-config.xml array New-2530-LCA
New-2530-LCA: : The xml was validated, and the array configuration cleared. An array import job was started.
4. Monitor the Job:
# sscs list -a New-2530-LCA jobs
Job ID: 2007.09.11.00.05.15.933 Status: In progress
# ./sscs list -a New-2530-LCA jobs 2007.09.11.00.05.15.933
Job ID: 2007.09.11.00.05.15.933
Type: Import Array
Status: In progress
% Complete: 78
Time to Completion: 00:00:12
Priority: Medium
# ./sscs list -a New-2530-LCA jobs 2007.09.11.00.05.15.933
Job ID: 2007.09.11.00.05.15.933
Type: Import Array
Status: Done
% Complete: 100
Time to Completion: 00:00:00
Priority: Unknown
5. Once the import job is completed we can see all our volumes, initiators and mapping are back:
# sscs list -a New-2530-LCA volume
Volume: vol1-Raid1 Seg 64k Type: Standard Pool: Raid 1 pool Profile: Raid 1 seg 64k
Volume: vol0-Raid5-64k Type: Standard Pool: Raid 5 pool Profile: Raid 5 Seg 64k
# sscs list -a New-2530-LCA volume vol0-Raid5-64k
Volume: vol0-Raid5-64k
Type: Standard
WWN: ---hidden---
Pool: Raid 5 pool
Profile: Raid 5 Seg 64k
Virtual Disk: 2
Size: 100.000 GB
State: Mapped
Status: Online
Action: Initializing... <----*
Condition: Optimal
Read Only: No
Controller: A
Preferred Controller: A
Modification Priority: High
Write Cache: Enabled
Write Cache with Replication: Enabled
Write Cache without Batteries: Disabled
Flush Cache After: 10 s
Disk Scrubbing: Enabled
Disk Scrubbing with Redundancy: Disabled
Associations:
Host: hostname.xxxx LUN: 1 Initiator: v4v-T2000b-HBA2 WWN: 50:06:05:B0:00:25:1F:E0 Permission: Read/Write
Host: hostname.xxxx LUN: 1 Initiator: v4v-T2000b-HBA1 WWN: 50:06:05:B0:00:25:1F:E4 Permission: Read/Write
# sscs list -a New-2530-LCA initiator
Initiator: v4v-T2000b-HBA2
Initiator: v4v-T2000b-HBA1
# sscs list -a New-2530-LCA initiator v4v-T2000b-HBA2
Initiator: v4v-T2000b-HBA2
WWN: 50:06:05:B0:00:25:1F:E0
Host: v4v-T2000b.singapore
OS Type: SOLAVT - Solaris (with Veritas DMP or other)
6. Restore/Import Array Profile Configuration:
Imports one or more profiles from a specified XML file. This allows you to import the configuration profile from one array to overwrite the configuration profile for this array.
sscs import -a <array-name> -f -x file:///tmp/all_profiles.xml profile
NOTE: When (-f) force option is used Existing and In Use profiles are not imported. New profiles, profiles with duplicate settings and conflicting profiles are imported.
If the force option is not specified, then Existing, Duplicate, Conflicting and In Use profiles are not imported, only new profiles are imported.
In all cases, both successful and failed imports are reported.
Example:
# sscs import -a New-2530-LCA -x file:///tmp/array-profile.xml profile
Oracle_OLTP_HA: Existing profile not imported
Raid 1 seg 64k: Existing profile not imported
Raid 5 Seg 64k: Existing profile not imported
test: New profile imported
Random_1: Existing profile not imported
Attachments
This solution has no attachment