Solution  1006858.1 :   OBP/SC parameters are reset after replacing motherboard  


Related Items
  • Sun Netra 210 Server
  •  
  • Sun Fire V240 Server
  •  
  • Sun Fire V210 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>NEBS-Certified Servers
  •  
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
209522


Description
To inform the Field organizations (Support Vendor, Re-Seller, &c.) that the OBP/SC parameters will be reset to factory default after replacing the motherboard.

Steps to Follow
On V210/V240, if the system board is replaced from a PN to a different PN, one cannot login the ALOM console using a user name that was set-up previously. This is due to the parameters on SCC are reset by ALOM. Thus, it is a must to set the SCC parameters again.
    --  Replace from failed M/B to the same PN :  Login OK
--  Replace from failed M/B to different PN : Login FAILED
As these customized user information are stored in the SCC, these SCC data is reset by ALOM after the system board replacement.  The reason being: The SCC is tied to the PN of the system board.
When replacing the system board with a different PN, the ALOM thinks the SCC is too different and issues a "set-defaults" to it.  This causes the lost of data that stored in SCC previously.  Therefore, after the replacement of the system board, the CU has to re-enter the users, passwords and other parameters.
This symptom was original found replacing 375-3122 with 375-3150.


Product
Netra 240 Server (AC)
Netra 240 Server
Netra 240 RoHS
Sun Netra 210 Server
Sun Netra 210 Server (AC)
Sun Fire V240 Server
Sun Fire V210 Server

Internal Comments
Please refer to the following for more accrue details of this symptom:



 Bug# 4953538, 4947649, 4936548, 6185008

Symptom Resolution <Document: 1006432.1>

ALOM, SCC
Previously Published As
88700

Change History
Date: 2009-11-19
User Name: Anthony Rulli
Action: Updated
Comment: currency check, audited by Anthony Rulli, Entry Level SPARC Content team
Verified Keywords - ok
Verified still correct for audience - currently set to contract
Audience left at contract as per FvF at
http://kmo.central/howto/content/voyager-contributor-standards.html
Checked review date - currently set to 2008-03-05
Checked for TM - none needed
Publishing under the current publication rules of 18 Apr 2005:
Version: 7
Date: 2007-06-19
User Name: 31620
Action: Accept

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback