Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1006722.1 : Using "vol verify" command on Sun StorEdge[TM] T3/T3+ Arrays
PreviouslyPublishedAs 209365 Description In order to provide you the most accurate fix, please validate that each statement under the symptoms below is true for your environment. These symptoms will hyperlink you into a relevant content that will 1) tell you how to validate the listed symptom and 2) how to fix the symptom if it is true for your environment. The listed symptoms are ordered in the most appropriate sequence to isolate the issue and be certain about the related fix. Please do not skip a step. Symptoms:
- Failed Hard Drive - Disk Scrubbing Steps to Follow Using "vol verify" command on Sun StorEdge[TM] T3/T3+ Arrays NOTE: This document describes how to check if the vol verify command should be executed. Vol verify is a disk scrubbing utility that verifies the integrity of the data on the disks. This document assumes you have already determined what drive has failed in step 2 of <Document: 1009745.1> Troubleshooting T3 Disk Failures To determine if you should use the vol verify command you will need to go through the following steps. Troubleshooting Steps: 1. Determine which version of T3 firmware is running by using the ver command: Example: storage-t3b:/:<13>ver T3B Release 3.1.6 Thu Feb 3 16:39:28 PST 2005 (10.1.229.133) Copyright (C) 1997-2003 Sun Microsystems, Inc. All Rights Reserved. 2. If you are running 3.x or higher verify disk_scrubber is enabled run the command sys list : Example: storage-t3b:/:<2>sys list 3. If disk_scrubber is not "on" or you running 2.x firmware run
the command 'vol verify fix' otherwise return to <Document: 1009745.1> Troubleshooting T3 Disk Failures NOTE: Vol verifies runs constanly if disk_scrubber is enabled and there is no need to use the vol verify command. Example: storage-t3b:/:<4>vol verify v1 fix 4.Once vol verify fix has completed return to <Document: 1009745.1> Troubleshooting T3 Disk Failures , step 4. Product Sun StorageTek T3+ Array Sun StorageTek T3 Array Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: [email protected] T3, T3+, vol verify, normalized, disk_scrubber, failed hard drive Previously Published As 86556 Change History Date: 2007-07-02 User Name: 7058 Action: Approved Comment: OK to publish. Will publish this doc's superset doc next. Notes for Normalizaton: Subset of: 86534 Subset Root path: 86556-->86534-->89034-->89031-->89050 References: N/A Project: Minnow Normalization Version: 8 Date: 2007-06-27 User Name: 71396 Action: Reassign Comment: minnow flow Version: 0 Date: 2007-06-27 User Name: 71396 Action: Accept Comment: Version: 0 Product_uuid 2a714b10-0a18-11d6-86e2-d56b387d4fbf|Sun StorageTek T3+ Array 2a6d7d50-0a18-11d6-8e0b-f0bd33b24928|Sun StorageTek T3 Array Attachments This solution has no attachment |
||||||||||||
|