Solution Type Technical Instruction Sure Solution 1006720.1 : Single failed hard drive in a Sun StorEdge[TM] T3 array
PreviouslyPublishedAs 209363 Description In order to provide you the most accurate fix, please validate that each statement under the symptoms below is true for your environment. These symptoms will hyperlink you into a relevant content that will 1) tell you how to validate the listed symptom and 2) how to fix the symptom if it is true for your environment. The listed symptoms are ordered in the most appropriate sequence to isolate the issue and be certain about the related fix. Please do not skip a step. Symptoms:
- failed drive - degraded LUN - ASC/ASCQ syslog messages Environmental Considerations: - This document assumes that a single drive failure has been validated. Steps to Follow Troubleshooting Steps: NOTE: This is a sub-set of Troubleshooting <Document: 1009745.1> : "Troubleshooting Sun StorEdge[TM] T3 Disk Failures." The steps below will help you in the replacement of a T3 disk and verifying the replacement was successful. If the drive has failed more than once, please recheck the syslog and fru stat output. 1. Initiate Disk replacement. Note: Retain the failed disk until after volume sync is completed after disk replacement. The volumes sync can be monitored with "proc list." This can take some time. 2. Verify the state of the drive replacement by using the 'vol stat' command. The volume and drive status in a mounted state confirms the drive replacement was successful. It may take a while for the drive replacement to complete as it copies data back to the replaced drive. Example: storage-t3b:/:<22>vol stat v1: mounted u1d05: mounted u1d06: mounted u1d07: mounted u1d08: mounted Standby: u1d09: mounted v3: mounted u2d05: mounted u2d06: mounted u2d07: mounted u2d08: mounted Standby: u2d09: mounted 3. If the disk replacement fails for the first time repeat the steps in Troubleshooting <Document: 1009745.1> : "Troubleshooting Sun StorEdge[TM] T3 Disk Failures." Product Sun StorageTek T3+ Array Sun StorageTek T3 Array Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK Place Sun Internal-Use Only content here. This content will be T3, T3+, disk, single drive, fault, failed, audited Previously Published As 86535 Change History Date: 2007-07-16 User Name: 7058 Action: Approved Comment: Notes for Normalizaton: Subset of:86534 Subset Root path: 86535-->86534 References: N/A Project: Minnow Normalization Version: 8 Date: 2007-06-27 User Name: 71396 Action: Reassign Comment: Minnow Flow Version: 0 Date: 2007-06-27 User Name: 71396 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|