Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1006718.1 : Correcting Sun StorEdge[TM] Data Replicator roles within the Sun StorEdge[TM] 6920 system
PreviouslyPublishedAs 209359 Description It is possible to misconfigure Sun[TM] StorEdge Data Replicator set roles within a Sun StorageTek 6920 system such that the same Sun StorEdge Data Replicator set is configured with the same role on both systems. This InfoDoc explains how to correct this mistake without loss of data or availability. Steps to Follow When a Sun StorEdge Data Replicator set is configured in a Sun StorEdge[TM] 6920 environment, the same set must be independently configured on both of the Sun StorageTek 6920 systems. The duplication of this configuration step means that it is possible to mistakenly configure the set on both systems with the same role ("primary" or "secondary"), instead of configuring the set on one system as "primary" and on the other system as "secondary". If such a misconfiguration is performed, the set will be unable to synchronize or replicate data. In order to correct this misconfiguration the following methods can be used. If the set has been configured as the "primary" role on both systems, follow this procedure: 1.1 Identify which system should have been configured as the "secondary" role. 1.2 For the set that should be the "secondary", modify the set parameters and change the role from "primary" to secondary". 1.3 Synchronize the set. If the set has been configured as the "secondary" role on both systems, follow this procedure: 2.1 Identify which system should have been configured as the "primary" role. 2.2 Delete the Sun StorEdge Data Replicator set from the system that should be the "primary". This will not affect the data contained on the volume, nor will it affect the availability of the volume. 2.3 Recreate the Sun StorEdge[TM] Data Replicator set on the same volume being sure to select the role as "primary". 2.4 Synchronize the set. For more information about the administration of the Sun StorEdge[TM] Data Replicator software within the Sun StorEdge[TM] 6920 system, refer to the following documents: 819-0117-10 Sun StorEdge[TM] 6920 System Getting Started Guide Product Sun StorageTek 6920 System Internal Comments See also the related bug: 6448198, "RM - If both sets are created as secondary role, you will need to delete and recreate a set." Contact [email protected] with questions or comments. Sun StorageTek 6920, Sun StorEdge Data Replicator, 6920, Data Replicator, remote replication Previously Published As 86486 Change History Date: 2006-11-01 User Name: 71396 Action: Approved Comment: Performed final review of article. Updated trademarking, Publishing. Version: 5 Date: 2006-10-27 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2006-10-27 User Name: C140303 Action: Approved Comment: Replaced the word Storagetek with StorEdge as 6920 is StorEdge not Storagetek and added TM sign for StorEdge Version: 0 Date: 2006-10-27 User Name: C140303 Action: Update Started Comment: needs update Version: 0 Date: 2006-08-07 User Name: 71396 Action: Approved Comment: Performed final review of article. Updated trademarking Publishing. Version: 3 Date: 2006-07-31 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2006-07-31 User Name: 37842 Action: Approved Comment: Looks good. Version: 0 Date: 2006-07-31 User Name: 37842 Action: Accept Comment: Version: 0 Date: 2006-07-31 User Name: 71921 Action: Approved Comment: This infodoc draft is a direct result of CR 6448198 which has been evaluated as needing resolution through documentation. The wording has been reviewed by the 6920 replication software team and the submitter of the bug. Version: 0 Date: 2006-07-31 User Name: 71921 Action: Created Comment: Version: 0 Product_uuid 67794720-356d-11d7-8ef2-ce2ac2bc9136|Sun StorageTek 6920 System Attachments This solution has no attachment |
||||||||||||
|