Solution  1006718.1 :   Correcting Sun StorEdge[TM] Data Replicator roles within the Sun StorEdge[TM] 6920 system  


Related Items
  • Sun Storage 6920 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
209359


Description

It is possible to misconfigure Sun[TM] StorEdge Data Replicator set roles within a Sun StorageTek 6920 system such that the same Sun StorEdge Data Replicator set is configured with the same role on both systems.

This InfoDoc explains how to correct this mistake without loss of data or availability.



Steps to Follow

When a Sun StorEdge Data Replicator set is configured in a Sun StorEdge[TM] 6920 environment, the same set must be independently configured on both of the Sun StorageTek 6920 systems. The duplication of this configuration step means that it is possible to mistakenly configure the set on both systems with the same role ("primary" or "secondary"), instead of configuring the set on one system as "primary" and on the other system as "secondary". If such a misconfiguration is performed, the set will be unable to synchronize or replicate data.

In order to correct this misconfiguration the following methods can be used.

If the set has been configured as the "primary" role on both systems, follow this procedure:

1.1 Identify which system should have been configured as the "secondary" role.

1.2 For the set that should be the "secondary", modify the set parameters and change the role from "primary" to secondary".

1.3 Synchronize the set.

If the set has been configured as the "secondary" role on both systems, follow this procedure:

2.1 Identify which system should have been configured as the "primary" role.

2.2 Delete the Sun StorEdge Data Replicator set from the system that should be the "primary". This will not affect the data contained on the volume, nor will it affect the availability of the volume.

2.3 Recreate the Sun StorEdge[TM] Data Replicator set on the same volume being sure to select the role as "primary".

2.4 Synchronize the set.

For more information about the administration of the Sun StorEdge[TM] Data Replicator software within the Sun StorEdge[TM] 6920 system, refer to the following documents:

819-0117-10 Sun StorEdge[TM] 6920 System Getting Started Guide
817-5228-10 Sun StorEdge[TM] 6920 System CLI Quick Reference Guide
819-0123-10 Sun StorEdge 6920[TM] System Administration Guide For the Browser Interface Management Software
819-0122-10 Best Practices for the Sun StorEdge[TM] 6920 System
819-3328-10 Sun StorEdge[TM] Data Replicator Software With Oracle Databases Usage Guide For Sun StorEdge[TM] 6920 Systems



Product
Sun StorageTek 6920 System

Internal Comments

See also the related bug: 6448198, "RM - If both sets are created as secondary role, you will need to delete and recreate a set."


Contact [email protected] with questions or comments.


Sun StorageTek 6920, Sun StorEdge Data Replicator, 6920, Data Replicator, remote replication
Previously Published As
86486

Change History
Date: 2006-11-01
User Name: 71396
Action: Approved
Comment: Performed final review of article.

Updated trademarking,

Publishing.
Version: 5
Date: 2006-10-27
User Name: 71396
Action: Accept
Comment:
Version: 0
Date: 2006-10-27
User Name: C140303
Action: Approved
Comment: Replaced the word Storagetek with StorEdge as 6920 is StorEdge not Storagetek and added TM sign for StorEdge
Version: 0
Date: 2006-10-27
User Name: C140303
Action: Update Started
Comment: needs update
Version: 0
Date: 2006-08-07
User Name: 71396
Action: Approved
Comment: Performed final review of article.

Updated trademarking

Publishing.
Version: 3
Date: 2006-07-31
User Name: 71396
Action: Accept
Comment:
Version: 0
Date: 2006-07-31
User Name: 37842
Action: Approved
Comment: Looks good.
Version: 0
Date: 2006-07-31
User Name: 37842
Action: Accept
Comment:
Version: 0
Date: 2006-07-31
User Name: 71921
Action: Approved
Comment: This infodoc draft is a direct result of CR 6448198 which has been evaluated as needing resolution through documentation. The wording has been reviewed by the 6920 replication software team and the submitter of the bug.
Version: 0
Date: 2006-07-31
User Name: 71921
Action: Created
Comment: