Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1006663.1 : Re-discovering a Sun StorEdge [TM] T3 Disk
PreviouslyPublishedAs 209292 Description After replacement of a T3 controller disk is not detected by T3 even though green LED is on. Steps to Follow During a customer escalation, the decision was made to replace a T3 controller. FW version was 1.18.04. After the maintenance action the following disk status was observed: t3two:/:<1>fru list ID TYPE VENDOR MODEL REVISION SERIAL ------ ----------------- ----------- ----------- ------------- -------- u1ctr controller card SLR-MI 375-0084-02- 0210 015137 u1d1 disk drive SEAGATE ST373405FSUN 0438 3EK0Y8VM u1d2 disk drive SEAGATE ST173404FSUN A42D 3CE0LJTB u1d3 disk drive SEAGATE ST173404FSUN A42D 3CE0L8GY u1d4 disk drive SEAGATE ST173404FSUN A42D 3CE0B36X u1d5 disk drive SEAGATE ST173404FSUN A42D 3CE0KZ5R u1d6 disk drive FUJITSU MAN3735F SUN 1004 03V84493 u1d7 disk drive SEAGATE ST173404FSUN AA27 3CE0NTJM u1d8 disk drive SEAGATE ST373307FSUN A507 3HZX0RB5 u1d9 disk drive u1l1 loop card SLR-MI 375-0085-01- 5.02 Flash 035952 u1l2 loop card SLR-MI 375-0085-01- 5.02 Flash 036700 u1pcu1 power/cooling unit TECTROL-CAN 300-1454-01( 0000 042522 u1pcu2 power/cooling unit TECTROL-CAN 300-1454-01( 0000 042486 u1mpn mid plane SLR-MI 370-3990-01- 0000 021875 As you can see u1d9 appears to be missing even though it had not been removed and the green LED was on. Customer had even tried power cycling the T3 and u1d9 remained undetected. Suggested workaround that enabled T3 to re-detect disk: - pull u1d9 from the array - while it is out record the vendor and model number of the drive and any other info on it - tail the t3 syslog to see if it recognizes the drive as missing - after it is out for 5 full minutes, re-insert it and observe the LED's - if it is recognized correctly you should see LED's flashing between u1d9 and probably u1d1 as the sysarea is being copied - look at fru list and fru stat again, look at vol list and vol stat After this workaround was implemented the following fru list was seen: o/t3data.80bdc091.uctfe8pr-2006.04.10.15.59/t3_2dedale/commands 309 $ pg fru_list fru list ID TYPE VENDOR MODEL REVISION SERIAL ------ ----------------- ----------- ----------- ------------- -------- u1ctr controller card SLR-MI 375-0084-02- 0210/011804 015137 u1d1 disk drive SEAGATE ST373405FSUN 0438 3EK0Y8VM u1d2 disk drive SEAGATE ST173404FSUN AF27 3CE0LJTB u1d3 disk drive SEAGATE ST173404FSUN AF27 3CE0L8GY u1d4 disk drive SEAGATE ST373207FSUN A55A 3632ECC0 u1d5 disk drive SEAGATE ST173404FSUN AF27 3CE0KZ5R u1d6 disk drive FUJITSU MAN3735F SUN 1004 03V84493 u1d7 disk drive SEAGATE ST173404FSUN AF27 3CE0NTJM u1d8 disk drive SEAGATE ST373307FSUN A507 3HZX0RB5 u1d9 disk drive FUJITSU MAN3735F SUN B704 10V45953 u1l1 loop card SLR-MI 375-0085-01- 5.02 Flash 035952 u1l2 loop card SLR-MI 375-0085-01- 5.02 Flash 036700 u1pcu1 power/cooling unit TECTROL-CAN 300-1454-01( 0000 042522 u1pcu2 power/cooling unit TECTROL-CAN 300-1454-01( 0000 042486 u1mpn mid plane SLR-MI 370-3990-01- 0000 021875 Product Sun StorageTek T3 Array Internal Comments This is from escalation 1-16271523, radiance case 37587806. T3, disk, missing, undetected Previously Published As 85454 Change History Date: 2006-05-03 User Name: 31620 Action: Approved Comment: Verified Metadata - ok Verified Keywords - ok Verified still correct for audience - currently set to contract Audience left at contract as per FvF http://kmo.central/howto/FvF.html Checked review date - currently set to 2007-04-26 Checked for TM - added appropriate for T3 Moved reference to escalation and radiance case numbers to internal only section Publishing under the current publication rules of 18 Apr 2005: Version: 4 Date: 2006-05-01 Attachments This solution has no attachment |
||||||||||||
|