Description

When NTP service is used in a T3+, the following messages could be present after
each ntp polling.

            NTPD[1]: I: select(): nfound = 0, error?
NTPD[1]: I: ts *: 0x2080be8 l_ui 0xffffffff l_uf 0x47788ad7
NTPD[1]: I: NTP done

This message is not reporting any error, NTPD is just informing that any time adjustment was needed.



Steps to Follow

In order to avoid the message, loglevel should be configured to 3 using T3+ command line interface.

</>set loglevel 3

Using the set command without options will show current loglevel configuration

The level of messages to be logged are:

0=none
1=errors
2=warnings/errors
3=notices/warnings/errors
4=informational/notices/warnings/errors

To find the ntp polling interval configuration, use the following CLI command:

</>ntp

More information could be found in the "Sun StorEdge T3+ Array Administrator's Manual" http://download.oracle.com/docs/cd/E19700-01/index.html

Refer to Chapter 9 (Network Time Protocol Configuration) for NTP guidelines
Refer to Chapter 12 (CLI Commands) for set and ntp command details.



Product
Sun StorageTek T3+ Array

ntpd, ntp, select():, nfound = 0, error?, t3+, NTP done, loglevel
Previously Published As
81360

Change History
Date: 2005-05-04
User Name: 25440
Action: Approved
Comment: Minor edits for Editorial Style Guide compliance.
Publishing.
Version: 4
Date: 2005-05-04
User Name: 25440
Action: Accept
Comment:
Version: 0
Date: 2005-05-04
User Name: 54413
Action: Approved
Comment: Good to go after changes made.
Version: 0
Date: 2005-04-28
User Name: 114886
Action: Approved
Comment: References have been included
Version: 0
Date: 2005-04-28
User Name: 54413
Action: Rejected
Comment: All very useful.

Please add a reference to where the setting of the log level is document in either a man page or a manual. This gives the reader the option to go off and find out more.
Version: 0
Date: 2005-04-28
User Name: 54413
Action: Accept
Comment:
Version: 0
Date: 2005-04-27
User Name: 114886
Action: Approved
Comment: I have attended a case reporting several messages as follow:
Apr 24 04:39:52 inbrick1 NTPD[1]: I: select(): nfound = 0, error?
Apr 24 04:39:52 inbrick1 NTPD[1]: I: ts *: 0x2080be8 l_ui 0xffffffff l_uf 0x47788ad7
Apr 24 04:39:52 inbrick1 NTPD[1]: I: NTP done


An CU comment that no useful information was found in our site regarding to this problem.

So, i decided to propose this document for further references.
Version: 0
Date: 2005-04-27
User Name: 114886
Action: Created
Comment:
Version: 0
Product_uuid
2a714b10-0a18-11d6-86e2-d56b387d4fbf|Sun StorageTek T3+ Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback