Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1006576.1 : Sun StorEdge[TM] T3+: How to avoid continuous NTPD message in /var/adm/messages file
PreviouslyPublishedAs 209181 Description When NTP service is used in a T3+, the following messages could be present after NTPD[1]: I: select(): nfound = 0, error? NTPD[1]: I: ts *: 0x2080be8 l_ui 0xffffffff l_uf 0x47788ad7 NTPD[1]: I: NTP done This message is not reporting any error, NTPD is just informing that any time adjustment was needed. Steps to Follow In order to avoid the message, loglevel should be configured to 3 using T3+ command line interface. </>set loglevel 3 Using the set command without options will show current loglevel configuration The level of messages to be logged are: 0=none To find the ntp polling interval configuration, use the following CLI command: </>ntp More information could be found in the "Sun StorEdge T3+ Array Administrator's Manual" http://download.oracle.com/docs/cd/E19700-01/index.html Refer to Chapter 9 (Network Time Protocol Configuration) for NTP guidelines Product Sun StorageTek T3+ Array ntpd, ntp, select():, nfound = 0, error?, t3+, NTP done, loglevel Previously Published As 81360 Change History Date: 2005-05-04 User Name: 25440 Action: Approved Comment: Minor edits for Editorial Style Guide compliance. Publishing. Version: 4 Date: 2005-05-04 User Name: 25440 Action: Accept Comment: Version: 0 Date: 2005-05-04 User Name: 54413 Action: Approved Comment: Good to go after changes made. Version: 0 Date: 2005-04-28 User Name: 114886 Action: Approved Comment: References have been included Version: 0 Date: 2005-04-28 User Name: 54413 Action: Rejected Comment: All very useful. Please add a reference to where the setting of the log level is document in either a man page or a manual. This gives the reader the option to go off and find out more. Version: 0 Date: 2005-04-28 User Name: 54413 Action: Accept Comment: Version: 0 Date: 2005-04-27 User Name: 114886 Action: Approved Comment: I have attended a case reporting several messages as follow: Apr 24 04:39:52 inbrick1 NTPD[1]: I: select(): nfound = 0, error? Apr 24 04:39:52 inbrick1 NTPD[1]: I: ts *: 0x2080be8 l_ui 0xffffffff l_uf 0x47788ad7 Apr 24 04:39:52 inbrick1 NTPD[1]: I: NTP done An CU comment that no useful information was found in our site regarding to this problem. So, i decided to propose this document for further references. Version: 0 Date: 2005-04-27 User Name: 114886 Action: Created Comment: Version: 0 Product_uuid 2a714b10-0a18-11d6-86e2-d56b387d4fbf|Sun StorageTek T3+ Array Attachments This solution has no attachment |
||||||||||||
|