Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1006468.1 : How to find the firmware revision (fcode version) of on-board ISP2200 chip
PreviouslyPublishedAs 209063 Description Ever need to find out the fcode version of the on-board ISP2200 chip? Steps to Follow The luxadm command will provide this information in a succinct output. Example: # luxadm qlgc_s_download Found Path to 1 FC100/P, ISP2200 Devices Opening Device: /devices/pci@8,600000/SUNW,qlc@2/fp@0,0:devctl Detected FCode Version: ISP2200 FC-AL Host Adapter Driver: 1.14 01/11/20 Complete The Fcode version in the example is 1.14 Most probably, once you've found the firmware revision, the next logical question will be how to update the firmware. The only way to update the on-board firmware for the ISP2200 is to update the OBP. See Bug 4454917 for more information. Product Sun Fire V880z Visualization Server Sun Fire V880 Server Sun Fire V480 Server Sun Fire V890 Server Sun Fire V490 Server Internal Comments Audited/updated 12/03/09 [email protected], Entry Level SPARC Content Team Member See Also: Symptom Resolution Document ID <Document: 1011833.1> . fcode, firmware, isp2200, qlogic, onboard Previously Published As 79331 Change History Date: 2004-12-29 User Name: 95826 Action: Approved Comment: - verified metadata - verified correct for audience - contract - changed review date to 2005-12-28 - checked for TM - none added Publishing Version: 4 Comment: Changed around wording, "The only way to update the on-board firmware for the ISP2200 is to update the OBP." Thanks Rick Version: 0 Attachments This solution has no attachment |
||||||||||||
|