Solution  1006136.1 :   Sun Fire[TM] v1280/E2900/3800/4800/4810/6800/E4900/E6900 & Netra 1280/1290: How to add CPUs and System Boards to a running domain  


Related Items
  • Sun Fire E4900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Netra 1280 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
208592


Applies to:

Sun Fire 4800 Server
Sun Fire 3800 Server
Sun Fire 6800 Server
Sun Netra 1280 Server - Version: Not Applicable and later    [Release: NA and later]
Sun Netra 1290 Server - Version: Not Applicable and later    [Release: NA and later]
All Platforms

Goal



Utilizing Dynamic Reconfiguration (DR) or cfgadm to add a System Board to a
domain.

The procedure outlined in this document can be used to enable a System Board which is not part of any running domain. With little modification this can be also used to replace a faulty System Board with a new one.

For 3800/48x0/6800/E4900/E6900, please refer to the Dynamic Reconfiguration (DR) on Sun Fire Midrange Server Release Notes to confirm the server meets the requirements. For v1280/E2900 or Netra 1280/1290, reference Chapter 10 of the Sun Fire Entry-Level System Administration Guide.

Also reference <Document 1003332.1> for all available DR options for the Sun Fire[TM] platforms.

Solution



Steps to Follow
The example procedure below is on a 6800 server and the board being added is SB1.

The following steps are basically the same regardless of the system (but for v1280/E2900/n1280/n1290, there is only one domain and the prompt is not the "SC" prompt, but instead, the "lom" prompt).

1) Make a note of the number of CPUs on the server for comparison purposes once the CPUs have been added

# /usr/sbin/psrinfo
0 on-line since 02/11/04 15:54:11
1 on-line since 02/11/04 15:54:12
2 on-line since 02/11/04 15:54:12
3 on-line since 02/11/04 15:54:12
#

2) Make a note of the current memory on the server, again, for comparison purposes

# cd /usr/platform/`uname -i`/sbin
# ./prtdiag -v
System Configuration: Sun Microsystems sun4u Sun Fire 6800
System clock frequency: 150 MHz
Memory size: 16384 Megabytes
========================= CPUs
===============================================
            Port  Run    E$   CPU      CPU
FRU Name ID MHz MB Impl. Mask
---------- ---- ---- ---- ------- ----
/N0/SB0/P0 0 1050 8.0 US-III+ 2.3
/N0/SB0/P1 1 1050 8.0 US-III+ 2.3
/N0/SB0/P2 2 1050 8.0 US-III+ 2.3
/N0/SB0/P3 3 1050 8.0 US-III+ 2.3
========================= Memory Configuration
===============================
                     Logical  Logical  Logical
Port Bank Bank Bank DIMM Interleave
Interleave
FRU Name ID Num Size Status Size Factor
Segment
------------- ---- ---- ------ ----------- ------ ----------
----------
/N0/SB0/P0/B0 0 0 1024MB pass 512MB 16-way 0
/N0/SB0/P0/B1 0 1 1024MB pass 512MB 16-way 0
/N0/SB0/P0/B0 0 2 1024MB pass 512MB 16-way 0
/N0/SB0/P0/B1 0 3 1024MB pass 512MB 16-way 0
/N0/SB0/P1/B0 1 0 1024MB pass 512MB 16-way 0
/N0/SB0/P1/B1 1 1 1024MB pass 512MB 16-way 0
/N0/SB0/P1/B0 1 2 1024MB pass 512MB 16-way 0
/N0/SB0/P1/B1 1 3 1024MB pass 512MB 16-way 0
/N0/SB0/P2/B0 2 0 1024MB pass 512MB 16-way 0
/N0/SB0/P2/B1 2 1 1024MB pass 512MB 16-way 0
/N0/SB0/P2/B0 2 2 1024MB pass 512MB 16-way 0
/N0/SB0/P2/B1 2 3 1024MB pass 512MB 16-way 0
/N0/SB0/P3/B0 3 0 1024MB pass 512MB 16-way 0
/N0/SB0/P3/B1 3 1 1024MB pass 512MB 16-way 0
/N0/SB0/P3/B0 3 2 1024MB pass 512MB 16-way 0
/N0/SB0/P3/B1 3 3 1024MB pass 512MB 16-way 0
========================= IO Cards =========================
                                Bus  Max                                  
            IO   Port Bus       Freq Bus  Dev,                            
FRU Name    Type  ID  Side Slot MHz  Freq Func State Name
Model
---------- ---- ---- ---- ---- ---- ---- ---- -----
-------------------------------- ----------------------
/N0/IB6/P0 PCI 24 B 0 33 33 1,0 ok
pci-pci1011,24.3/pci108e,1000 pci-bridge
/N0/IB6/P0  PCI   24   B    0    33   33  0,0  ok
pci108e,1000-pci108e,1000.1
/N0/IB6/P0  PCI   24   B    0    33   33  0,1  ok    SUNW,hme-pci108e,1001
SUNW,
cheerio
/N0/IB6/P0 PCI 24 B 0 33 33 4,0 ok
SUNW,isptwo-pci1077,1020/sd (blo+
QLGC,ISP1040B
/N0/IB6/P0 PCI 24 B 1 33 33 2,0 ok
pci108e,1000-pci108e,1000.1
/N0/IB6/P0  PCI   24   B    1    33   33  2,1  ok    SUNW,hme-pci108e,1001
SUNW,
qsi-cheerio
/N0/IB6/P1 PCI 25 B 5 33 33 2,0 ok JNI,FCR/sd (block)
FCE-6460-N
/N0/IB7/P0  PCI   26   B    1    33   33  2,0  ok
pci-pci1011,25.4/pci108e,1000 pci-bridge
/N0/IB7/P0  PCI   26   B    1    33   33  0,0  ok
pci108e,1000-pci108e,1000.1
/N0/IB7/P0  PCI   26   B    1    33   33  0,1  ok    SUNW,qfe-pci108e,1001
SUNW,
pci-qfe
/N0/IB7/P0 PCI 26 B 1 33 33 1,0 ok
pci108e,1000-pci108e,1000.1
/N0/IB7/P0  PCI   26   B    1    33   33  1,1  ok    SUNW,qfe-pci108e,1001
SUNW,
pci-qfe
/N0/IB7/P0 PCI 26 B 1 33 33 2,0 ok
pci108e,1000-pci108e,1000.1
/N0/IB7/P0  PCI   26   B    1    33   33  2,1  ok    SUNW,qfe-pci108e,1001
SUNW,
pci-qfe
/N0/IB7/P0 PCI 26 B 1 33 33 3,0 ok
pci108e,1000-pci108e,1000.1
/N0/IB7/P0  PCI   26   B    1    33   33  3,1  ok    SUNW,qfe-pci108e,1001
SUNW,
pci-qfe
/N0/IB7/P0 PCI 26 B 2 33 33 3,0 ok
SUNW,qlc-pci1077,2200.1077.4082.+
========================= Active Boards for Domain
===========================
          Power  Fault  HotPlug  Board
FRU Name LED LED LED Cond.
-------- ----- ----- ------- -------
/N0/SB0 on off off ok
/N0/IB6 on off off ok
/N0/IB7 on off off ok
========================= Available Boards/Slots for Domain
==================
          Power  Fault  HotPlug  Board/Slot  Board/Slot
FRU Name LED LED LED Condition Assigned
-------- ----- ----- ------- ---------- ----------
/SB1 off off on Unknown no
/SB2 on off off Unknown no
/SB4 off off off Empty yes
/SB5 off off off Empty yes
/IB8 on off off Unknown no
========================= Hardware Failures
==================================
No Hardware failures found in System
========================= HW Revisions =======================================
System PROM revisions:
----------------------
OBP 5.15.1 05/29/03 17:05
IO ASIC revisions:
------------------
Port
FRU Name Model ID Status Version
----------- --------------- ---- ------ -------
/N0/IB6/P0 SUNW,schizo 24 ok 3
/N0/IB6/P1 SUNW,schizo 25 ok 3
/N0/IB7/P0 SUNW,schizo 26 ok 3
/N0/IB7/P1 SUNW,schizo 27 ok 3
/N0/IB6/P0 SUNW,sgsbbc 24 ok 2
/N0/IB7/P0 SUNW,sgsbbc 26 ok 2
#

3) View from the system controller

v4u-6800a-sc1-gmp02:SC> showboards
Slot     Pwr Component Type                 State      Status     Domain
---- --- -------------- ----- ------ ------
SSC1 On System Controller Main Passed -
SSC0 On System Controller Spare - -
ID0 On Sun Fire 6800 Centerplane - OK -
PS0 On A152 Power Supply - OK -
PS1 On A152 Power Supply - OK -
PS2 On A152 Power Supply - OK -
PS3 On A152 Power Supply - OK -
PS4 On A152 Power Supply - OK -
PS5 On A152 Power Supply - OK -
FT0 On Fan Tray Low Speed OK -
FT1 On Fan Tray Low Speed OK -
FT2 On Fan Tray Low Speed OK -
FT3 On Fan Tray Low Speed OK -
RP0 On Repeater Board - OK -
RP1 On Repeater Board - OK -
RP2 On Repeater Board - OK -
RP3 On Repeater Board - OK -
/N0/SB0 On CPU Board V2 Active Passed A
SB1 Off CPU Board V2 Available Not tested Isolated
SB2 On CPU Board V2 Available Not tested Isolated
/N0/SB3 On CPU Board V2 Assigned Not tested D
/N0/IB6 On PCI I/O Board Active Passed A
/N0/IB7 On PCI I/O Board Active Passed A
IB8 On Fire Link/CPCI I/O Board Available Not tested Isolated
/N0/IB9 On Fire Link/CPCI I/O Board Assigned Not tested D

4) Use cfgadm to determine the attachment point (AP) ID for system boards.

# /usr/sbin/cfgadm -l -s "select=class(sbd)"
Ap_Id Type Receptacle Occupant
Condition
N0.IB6 PCI_I/O_Boa connected configured ok
N0.IB7 PCI_I/O_Boa connected configured ok
N0.IB8 Fire_Link/C disconnected unconfigured unknown
N0.SB0 CPU_V2 connected configured ok
N0.SB1 CPU_V2 disconnected unconfigured unknown
N0.SB2 CPU_V2 disconnected unconfigured unknown
N0.SB4 unknown empty unconfigured unknown
N0.SB5 unknown empty unconfigured unknown
#
# /usr/sbin/cfgadm -a
Ap_Id Type Receptacle Occupant
Condition
N0.IB6 PCI_I/O_Boa connected configured ok
N0.IB6::pci0 io connected configured ok
N0.IB6::pci1 io connected configured ok
N0.IB6::pci2 io connected configured ok
N0.IB6::pci3 io connected configured ok
N0.IB7 PCI_I/O_Boa connected configured ok
N0.IB7::pci0 io connected configured ok
N0.IB7::pci1 io connected configured ok
N0.IB7::pci2 io connected configured ok
N0.IB7::pci3 io connected configured ok
N0.IB8 Fire_Link/C disconnected unconfigured unknown
N0.SB0 CPU_V2 connected configured ok
N0.SB0::cpu0 cpu connected configured ok
N0.SB0::cpu1 cpu connected configured ok
N0.SB0::cpu2 cpu connected configured ok
N0.SB0::cpu3 cpu connected configured ok
N0.SB0::memory memory connected configured ok
N0.SB1 CPU_V2 disconnected unconfigured unknown
N0.SB2 CPU_V2 disconnected unconfigured unknown
N0.SB4 unknown empty unconfigured unknown
N0.SB5 unknown empty unconfigured unknown
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown

NOTE: We will use dynamic Reconfigueration (DR) to attach SB1

5) If necessary Poweron SB1

v4u-6800a-sc1-gmp02:SC> poweron sb1
SB1: powered on
v4u-6800a-sc1-gmp02:SC>
v4u-6800a-sc1-gmp02:SC> showboards
Slot     Pwr Component Type                 State      Status     Domain
---- --- -------------- ----- ------ ------
SSC1 On System Controller Main Passed -
SSC0 On System Controller Spare - -
ID0 On Sun Fire 6800 Centerplane - OK -
PS0 On A152 Power Supply - OK -
PS1 On A152 Power Supply - OK -
PS2 On A152 Power Supply - OK -
PS3 On A152 Power Supply - OK -
PS4 On A152 Power Supply - OK -
PS5 On A152 Power Supply - OK -
FT0 On Fan Tray Low Speed OK -
FT1 On Fan Tray Low Speed OK -
FT2 On Fan Tray Low Speed OK -
FT3 On Fan Tray Low Speed OK -
RP0 On Repeater Board - OK -
RP1 On Repeater Board - OK -
RP2 On Repeater Board - OK -
RP3 On Repeater Board - OK -
/N0/SB0 On CPU Board V2 Active Passed A
SB1 On CPU Board V2 Available Not tested Isolated
SB2 On CPU Board V2 Available Not tested Isolated
/N0/SB3 On CPU Board V2 Assigned Not tested D
/N0/IB6 On PCI I/O Board Active Passed A
/N0/IB7 On PCI I/O Board Active Passed A
IB8 On Fire Link/CPCI I/O Board Available Not tested Isolated
/N0/IB9 On Fire Link/CPCI I/O Board Assigned Not tested D
v4u-6800a-sc1-gmp02:SC> 

6) Configure the domain from the system controller to use SB1.

Please be aware that the target SB to be added to the domain MUST be in the domain's Access Control List (ACL). This can be checked using the showplatform -v command on the platform shell. If modification is needed to the Domain's ACL, the platform shell command setupplatform should be used.

v4u-6800a-sc1-gmp02:SC> addboard -d a sb1
/N0/SB1: will be configured into the domain after setkeyswitch off/standby
DR can be used to configure /N0/SB1 into an active domain.
v4u-6800a-sc1-gmp02:SC>
v4u-6800a-sc1-gmp02:SC> showboard
Slot     Pwr Component Type                 State      Status     Domain
---- --- -------------- ----- ------ ------
SSC1 On System Controller Main Passed -
SSC0 On System Controller Spare - -
ID0 On Sun Fire 6800 Centerplane - OK -
PS0 On A152 Power Supply - OK -
PS1 On A152 Power Supply - OK -
PS2 On A152 Power Supply - OK -
PS3 On A152 Power Supply - OK -
PS4 On A152 Power Supply - OK -
PS5 On A152 Power Supply - OK -
FT0 On Fan Tray Low Speed OK -
FT1 On Fan Tray Low Speed OK -
FT2 On Fan Tray Low Speed OK -
FT3 On Fan Tray Low Speed OK -
RP0 On Repeater Board - OK -
RP1 On Repeater Board - OK -
RP2 On Repeater Board - OK -
RP3 On Repeater Board - OK -
/N0/SB0 On CPU Board V2 Active Passed A
/N0/SB1 On CPU Board V2 Assigned Not tested A
SB2 On CPU Board V2 Available Not tested Isolated
/N0/SB3 On CPU Board V2 Assigned Not tested D
/N0/IB6 On PCI I/O Board Active Passed A
/N0/IB7 On PCI I/O Board Active Passed A
IB8 On Fire Link/CPCI I/O Board Available Not tested Isolated
/N0/IB9 On Fire Link/CPCI I/O Board Assigned Not tested D
v4u-6800a-sc1-gmp02:SC> 

7) Run POST on the System Board to be added to the running domain:

# /usr/sbin/cfgadm -t N0.SB1
{/N0/SB1/P0} Running CPU POR and Set Clocks
{/N0/SB1/P2} Running CPU POR and Set Clocks
{/N0/SB1/P3} Running CPU POR and Set Clocks
{/N0/SB1/P1} Running CPU POR and Set Clocks
.....
.......
{/N0/SB1/P3} Subtest: Board Memory Interleave Configuration
{/N0/SB1/P0} Passed
{/N0/SB1/P1} Passed
{/N0/SB1/P2} Passed
{/N0/SB1/P3} Passed
{/N0/SB1/P0} DCB_ENTER_OBP command succeeded
{/N0/SB1/P1} DCB_ENTER_OBP command succeeded
{/N0/SB1/P2} DCB_ENTER_OBP command succeeded
{/N0/SB1/P3} DCB_ENTER_OBP command succeeded
#

NOTE: Confirm there are no errors reported during this step.

8) Configure the domain using cfgadm to use SB1

# /usr/sbin/cfgadm -o platform=diag=init -c configure N0.SB1

9) Use cfgadm to verify the above operation

# /usr/sbin/cfgadm -a N0.SB1
Ap_Id Type Receptacle Occupant
Condition
N0.SB1 CPU_V2 connected configured ok
N0.SB1::cpu0 cpu connected configured ok
N0.SB1::cpu1 cpu connected configured ok
N0.SB1::cpu2 cpu connected configured ok
N0.SB1::cpu3 cpu connected configured ok
N0.SB1::memory memory connected configured ok
#
# /usr/sbin/cfgadm -av N0.SB1
Ap_Id Receptacle Occupant Condition
Information
When Type Busy Phys_Id
N0.SB1 connected configured ok
powered-on, assigned
Feb 11 16:54 CPU_V2 n /devices/ssm@0,0:N0.SB1
N0.SB1::cpu0 connected configured ok cpuid
4, speed 1050 MHz,
ecache 8 MBytes
Feb 11 16:54 cpu n /devices/ssm@0,0:N0.SB1::cpu0
N0.SB1::cpu1 connected configured ok cpuid
5, speed 1050 MHz,
ecache 8 MBytes
Feb 11 16:54 cpu n /devices/ssm@0,0:N0.SB1::cpu1
N0.SB1::cpu2 connected configured ok cpuid
6, speed 1050 MHz,
ecache 8 MBytes
Feb 11 16:54 cpu n /devices/ssm@0,0:N0.SB1::cpu2
N0.SB1::cpu3 connected configured ok cpuid
7, speed 1050 MHz,
ecache 8 MBytes
Feb 11 16:54 cpu n /devices/ssm@0,0:N0.SB1::cpu3
N0.SB1::memory connected configured ok base
address 0x2000000000,
33554432 KBytes total
Feb 11 16:54 memory n /devices/ssm@0,0:N0.SB1::memory

10) Confirm the domain can see the new CPUs

# /usr/sbin/psrinfo
0 on-line since 02/11/04 15:54:11
1 on-line since 02/11/04 15:54:12
2 on-line since 02/11/04 15:54:12
3 on-line since 02/11/04 15:54:12
4 on-line since 02/11/04 16:54:37
5 on-line since 02/11/04 16:54:37
6 on-line since 02/11/04 16:54:37
7 on-line since 02/11/04 16:54:37
#

11) Confirm the additional memory is available.

# /usr/sbin/prtconf | more
System Configuration: Sun Microsystems sun4u
Memory size: 49152 Megabytes
System Peripherals (Software Nodes):
SUNW,Sun-Fire

12) Use prtdiag to verify the new configuration.

# cd /usr/platform/`uname -i`/sbin
# ./prtdiag
System Configuration: Sun Microsystems sun4u Sun Fire 6800
System clock frequency: 150 MHz
Memory size: 49152 Megabytes
========================= CPUs
===============================================
            Port  Run    E$   CPU      CPU
FRU Name ID MHz MB Impl. Mask
---------- ---- ---- ---- ------- ----
/N0/SB0/P0 0 1050 8.0 US-III+ 2.3
/N0/SB0/P1 1 1050 8.0 US-III+ 2.3
/N0/SB0/P2 2 1050 8.0 US-III+ 2.3
/N0/SB0/P3 3 1050 8.0 US-III+ 2.3
/N0/SB1/P0 4 1050 8.0 US-III+ 2.3
/N0/SB1/P1 5 1050 8.0 US-III+ 2.3
/N0/SB1/P2 6 1050 8.0 US-III+ 2.3
/N0/SB1/P3 7 1050 8.0 US-III+ 2.3
========================= Memory Configuration
===============================
                     Logical  Logical  Logical
Port Bank Bank Bank DIMM Interleave
Interleave
FRU Name ID Num Size Status Size Factor
Segment
------------- ---- ---- ------ ----------- ------ ----------
----------
/N0/SB0/P0/B0 0 0 1024MB pass 512MB 16-way 0
/N0/SB0/P0/B1 0 1 1024MB pass 512MB 16-way 0
/N0/SB0/P0/B0 0 2 1024MB pass 512MB 16-way 0
/N0/SB0/P0/B1 0 3 1024MB pass 512MB 16-way 0
/N0/SB0/P1/B0 1 0 1024MB pass 512MB 16-way 0
/N0/SB0/P1/B1 1 1 1024MB pass 512MB 16-way 0
/N0/SB0/P1/B0 1 2 1024MB pass 512MB 16-way 0
/N0/SB0/P1/B1 1 3 1024MB pass 512MB 16-way 0
/N0/SB0/P2/B0 2 0 1024MB pass 512MB 16-way 0
/N0/SB0/P2/B1 2 1 1024MB pass 512MB 16-way 0
/N0/SB0/P2/B0 2 2 1024MB pass 512MB 16-way 0
/N0/SB0/P2/B1 2 3 1024MB pass 512MB 16-way 0
/N0/SB0/P3/B0 3 0 1024MB pass 512MB 16-way 0
/N0/SB0/P3/B1 3 1 1024MB pass 512MB 16-way 0
/N0/SB0/P3/B0 3 2 1024MB pass 512MB 16-way 0
/N0/SB0/P3/B1 3 3 1024MB pass 512MB 16-way 0
/N0/SB1/P0/B0 4 0 2048MB pass 1024MB 16-way 1
/N0/SB1/P0/B1 4 1 2048MB pass 1024MB 16-way 1
/N0/SB1/P0/B0 4 2 2048MB pass 1024MB 16-way 1
/N0/SB1/P0/B1 4 3 2048MB pass 1024MB 16-way 1
/N0/SB1/P1/B0 5 0 2048MB pass 1024MB 16-way 1
/N0/SB1/P1/B1 5 1 2048MB pass 1024MB 16-way 1
/N0/SB1/P1/B0 5 2 2048MB pass 1024MB 16-way 1
/N0/SB1/P1/B1 5 3 2048MB pass 1024MB 16-way 1
/N0/SB1/P2/B0 6 0 2048MB pass 1024MB 16-way 1
/N0/SB1/P2/B1 6 1 2048MB pass 1024MB 16-way 1
/N0/SB1/P2/B0 6 2 2048MB pass 1024MB 16-way 1
/N0/SB1/P2/B1 6 3 2048MB pass 1024MB 16-way 1
/N0/SB1/P3/B0 7 0 2048MB pass 1024MB 16-way 1
/N0/SB1/P3/B1 7 1 2048MB pass 1024MB 16-way 1
/N0/SB1/P3/B0 7 2 2048MB pass 1024MB 16-way 1
/N0/SB1/P3/B1 7 3 2048MB pass 1024MB 16-way 1
========================= IO Cards =========================
                                Bus  Max                                  
            IO   Port Bus       Freq Bus  Dev,                            
FRU Name    Type  ID  Side Slot MHz  Freq Func State Name
Model
---------- ---- ---- ---- ---- ---- ---- ---- -----
-------------------------------- ----------------------
/N0/IB6/P0 PCI 24 B 0 33 33 1,0 ok
pci-pci1011,24.3/pci108e,1000 pci-bridge
/N0/IB6/P0  PCI   24   B    0    33   33  0,0  ok
pci108e,1000-pci108e,1000.1
/N0/IB6/P0  PCI   24   B    0    33   33  0,1  ok    SUNW,hme-pci108e,1001
SUNW,
cheerio
/N0/IB6/P0 PCI 24 B 0 33 33 4,0 ok
SUNW,isptwo-pci1077,1020/sd (blo+
QLGC,ISP1040B
/N0/IB6/P0 PCI 24 B 1 33 33 2,0 ok
pci108e,1000-pci108e,1000.1
/N0/IB6/P0  PCI   24   B    1    33   33  2,1  ok    SUNW,hme-pci108e,1001
SUNW,
qsi-cheerio
/N0/IB6/P1 PCI 25 B 5 33 33 2,0 ok JNI,FCR/sd (block)
FCE-6460-N
/N0/IB7/P0  PCI   26   B    1    33   33  2,0  ok
pci-pci1011,25.4/pci108e,1000 pci-bridge
/N0/IB7/P0  PCI   26   B    1    33   33  0,0  ok
pci108e,1000-pci108e,1000.1
/N0/IB7/P0  PCI   26   B    1    33   33  0,1  ok    SUNW,qfe-pci108e,1001
SUNW,
pci-qfe
/N0/IB7/P0 PCI 26 B 1 33 33 1,0 ok
pci108e,1000-pci108e,1000.1
/N0/IB7/P0  PCI   26   B    1    33   33  1,1  ok    SUNW,qfe-pci108e,1001
SUNW,
pci-qfe
/N0/IB7/P0 PCI 26 B 1 33 33 2,0 ok
pci108e,1000-pci108e,1000.1
/N0/IB7/P0  PCI   26   B    1    33   33  2,1  ok    SUNW,qfe-pci108e,1001
SUNW,
pci-qfe
/N0/IB7/P0 PCI 26 B 1 33 33 3,0 ok
pci108e,1000-pci108e,1000.1
/N0/IB7/P0  PCI   26   B    1    33   33  3,1  ok    SUNW,qfe-pci108e,1001
SUNW,
pci-qfe
/N0/IB7/P0 PCI 26 B 2 33 33 3,0 ok
SUNW,qlc-pci1077,2200.1077.4082.+
========================= Active Boards for Domain
===========================
          Power  Fault  HotPlug  Board
FRU Name LED LED LED Cond.
-------- ----- ----- ------- -------
/N0/SB0 on off off ok
/N0/SB1 on off off ok
/N0/IB6 on off off ok
/N0/IB7 on off off ok
========================= Available Boards/Slots for Domain
==================
          Power  Fault  HotPlug  Board/Slot  Board/Slot
FRU Name LED LED LED Condition Assigned
-------- ----- ----- ------- ---------- ----------
/SB2 on off off Unknown no
/SB4 off off off Empty yes
/SB5 off off off Empty yes
/IB8 on off off Unknown no
========================= Hardware Failures
==================================
No Hardware failures found in System
# 

13) Check /var/adm/messages for confirmation

# cat /var/adm/messages
.....
......
Feb 11 16:54:24 v4u-6800a-doma-gmp02 unix: [ID 882636 kern.warning] WARNING: interrupt level 6 not serviced
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu4: (upaid 4 impl 0x15 ver 0x23 clock 1050 MHz)
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu5: (upaid 5 impl 0x15 ver 0x23 clock 1050 MHz)
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu6: (upaid 6 impl 0x15 ver 0x23 clock 1050 MHz)
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu7: (upaid 7 impl 0x15 ver 0x23 clock 1050 MHz)
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 4 initialization complete - restarted
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 5 initialization complete - restarted
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 6 initialization complete - restarted
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 7 initialization complete - restarted
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 700753 kern.info] kphysm_add_memory_dynamic: adding 33554432K at 0x2000000000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 unix: [ID 323408 kern.info] kphysm_add_memory_dynamic: mem = 50331648K (0xc00000000)
Feb 11 16:54:52 v4u-6800a-doma-gmp02 unix: [ID 401001 kern.info] kphysm_add_memory_dynamic: avail mem = 50328207360
Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller4 at ssm0: Node 0 Safari id 4 0x2400000 ...
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us34 is /ssm@0,0/memory-controller@4,400000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@4,400000 (mc-us34) online
Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller5 at ssm0: Node 0 Safari id 5 0x2c00000 ...
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us35 is /ssm@0,0/memory-controller@5,400000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@5,400000 (mc-us35) online
Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller6 at ssm0: Node 0 Safari id 6 0x3400000 ...
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us36 is /ssm@0,0/memory-controller@6,400000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@6,400000 (mc-us36) online
Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller7 at ssm0: Node 0 Safari id 7 0x3c00000 ...
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us37 is /ssm@0,0/memory-controller@7,400000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@7,400000 (mc-us37) online
#


Product
Sun Fire 6800 Server
Sun Fire 4800 Server
Sun Fire 3800 Server

DR, Dynamic Reconfiguration, 3800, 4800, 6800, addboard