Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1006049.1 : Sun StorEdge[TM] 3910/3960/6910/6960 series: How to set a Sun StorEdge[TM] T3+ array password
PreviouslyPublishedAs 208436 Description The /opt/SUNWsecfg/runsecfg utility, and command line scripts in the /opt/SUNWsecfg/bin directory, may receive a PASSWD ENV variable error, if the Sun StorEdge[TM] T3+ array password is improperly set. Steps to Follow By default, the Sun StorEdge T3+ arrays in a StorEdge[TM] 3900/6900 series, have no password set. When prompted for a password, just press the "Enter/Return" key to gain access to the Sun StorEdge T3+ arrays. If your passwords on the Sun StorEdge T3+ arrays are null, do not set the PASSWD If the password on the T3+ does not match the PASSWD environment variable on the root# /opt/SUNWsecfg/bin/showt3 -n t3b0 ERROR: t3b0 : login failed: bad name or password. ERROR: t3b0 : ENV variable PASSWD must be set to the T3+ password. Use the method below to properly set the passwords in the Sun StorEdge T3+ 1) Telnet into the Sun StorEdge T3+ arrays, and use the passwd command to set a new password: Telnet session (192.168.0.40 or t3b0) Login: root Password: T3B Release 2.01.01 2002/07/30 19:16:42 (192.168.0.40) Copyright (C) 1997-2001 Sun Microsystems, Inc. All Rights Reserved. t3b0:/:<1>passwd OLD password:<enter> NEW password:sun NEW password (confirm): sun t3b0:/:<2> exit 2) Telnet into the service processor and edit the file: /.profile or /etc/profile to include the following modifications: Add "PASSWD={new T3+ password}" line before the export line. (for example: PASSWD=sunt3) Append "PASSWD" to the end of export line (ie: export PATH MANPATH FPATH PS1 PASSWD) 3) Logout and log back into the SE3900/6900 service processor for the PASSWD variable to take effect. The /opt/SUNWsecfg/runsecfg and scripts in /opt/SUNWsecfg/bin should now For more information on setting the PASSWD variable,see: Product Sun StorageTek 3910 Sun StorageTek 6960 Sun StorageTek 6910 Sun StorageTek 6900 Series Sun StorageTek 3900 Series Sun StorageTek 3960 Sun StorageTek T3 Array Internal Comments Reference: - Bug ID 4518880 "docs and t3utility man pages should mention password, t3, 3900, 3910, 3960, 6900, 6910, 6960 Previously Published As 49701 Change History Date: 2006-01-18 User Name: 97961 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT. [email protected] KDO Knowledge Engineer Version: 0 Date: 2006-01-18 User Name: 97961 Date: 2005-04-14 User Name: 18392 Action: Approved Comment: Added product names, product nouns, added STM, did some formatting, corrected grammar. Attachments This solution has no attachment |
||||||||||||
|