Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1005988.1
Update Date:2011-01-18
Keywords:

Solution Type  Technical Instruction Sure

Solution  1005988.1 :   Sun StorEdge[TM] L9 Autoloader Diagnostic Tests  


Related Items
  • Sun Storage L9 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
208358


Applies to:

Sun Storage L9 Tape Library
All Platforms
Reviewed for relevance on 18-Jan-2011.

Goal

This document aims to outline the available diagnostic tests that can be performed on the Sun StorEdge[TM] L9 Autoloader ...

Solution

A comprehensive list of test details are available in the 'Sun StorEdge L9 User and Service Guide'.

Steps to Follow
All diagnostic tests are performed from the front panel on the StorEdge L9 autoloader .
    Main Menu -> Administration -> Run Test
Use the following procedure to run internal tests of autoloader functions.
Table 1 describes these tests.
o  From 'Administration', select [More] to display additional
administrative options. Select the 'Run Test' menu.
o  From 'Run Test', use the [-] or [+] key to view available tests.
o  Select [OK] to select the test.
o  Select the number of times this test will run (if more than one
cycle is available and desired).
o  Select [Run] to start the test cycle. All test results are
displayed at the conclusion of the test cycle.
NOTE: Select [Stop] to abort a running test. The current test cycle
completes and the test stops. Stopping the test may take a few
minutes to complete.
________________________________________________________________________
Table 1 : Front Panel Diagnostic Tests
[o] Check Inventory
Physically scans the entire autoloader to determine the location, status,
and barcode information of tapes.
[o] Recalibrate Loader
Performs the power-up self-tests. Each test runs one time per test
loop. This test recalibrates the mechanics and clears hard errors,
but not the hard error log.
[o] Test Lateral Motion
Moves the transport assembly to a random slot. No tape is required.
[o] Test Magazine Moves
Moves a tape from a random slot to an empty, random slot, and then
returns it to the original location.
[o] Wellness Test
Moves a tape from a random slot to an empty drive and back to its original
location.
[o] Rewind Media
Rewinds the tape in the drive.
CAUTION: Do not run this test if the drive contains a tape that is
receiving data from the host.
[o] Lock Transport
Locks the transport assembly in place to allow for shipping the Autoloader.
			
NOTE: The only way to unlock the transport after you run this
test is to run the Unlock Transport test or power cycle
the autoloader.
			
[o] Unlock Transport
Unlocks the transport assembly if you want to unlock the transport without
power cycling the autoloader. The transport must have already been locked
to use this test.
[o] Back Magazine Removal
Moves the transport so that you can access the back magazine for drive
upgrades.
[o] Test Transport Comm
Exercises the internal infra-red communications path between the autoloader
controller and the transport micro-controller.   Reports the  health of
this link. If the test passes, the infra-red communication link is good.
[o] Show All Sensors
Dynamically displays the state of the door sensor. To toggle the door
sensor, open and close the door.
[o] Demonstration
Selects a random full storage slot and moves the tape to the drive.
The test locates a full slot, a full drive, an empty slot, and then
performs an exchange.
CAUTION: Run an inventory check from the host backup application
after performing this test since the tapes will be in
a different order.


@ L9, diagnostic, test, inventory, recalibrate, wellness, transport, storedge, library, surestor
Previously Published As 70512



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback