Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1005988.1 : Sun StorEdge[TM] L9 Autoloader Diagnostic Tests
PreviouslyPublishedAs 208358
Applies to:Sun Storage L9 Tape LibraryAll Platforms Reviewed for relevance on 18-Jan-2011. GoalThis document aims to outline the available diagnostic tests that can be performed on the Sun StorEdge[TM] L9 Autoloader ...SolutionA comprehensive list of test details are available in the 'Sun StorEdge L9 User and Service Guide'.Steps to Follow All diagnostic tests are performed from the front panel on the StorEdge L9 autoloader . Main Menu -> Administration -> Run Test Use the following procedure to run internal tests of autoloader functions. Table 1 describes these tests. o From 'Administration', select [More] to display additional administrative options. Select the 'Run Test' menu. o From 'Run Test', use the [-] or [+] key to view available tests. o Select [OK] to select the test. o Select the number of times this test will run (if more than one cycle is available and desired). o Select [Run] to start the test cycle. All test results are displayed at the conclusion of the test cycle. NOTE: Select [Stop] to abort a running test. The current test cycle completes and the test stops. Stopping the test may take a few minutes to complete. ________________________________________________________________________ Table 1 : Front Panel Diagnostic Tests [o] Check Inventory Physically scans the entire autoloader to determine the location, status, and barcode information of tapes. [o] Recalibrate Loader Performs the power-up self-tests. Each test runs one time per test loop. This test recalibrates the mechanics and clears hard errors, but not the hard error log. [o] Test Lateral Motion Moves the transport assembly to a random slot. No tape is required. [o] Test Magazine Moves Moves a tape from a random slot to an empty, random slot, and then returns it to the original location. [o] Wellness Test Moves a tape from a random slot to an empty drive and back to its original location. [o] Rewind Media Rewinds the tape in the drive. CAUTION: Do not run this test if the drive contains a tape that is receiving data from the host. [o] Lock Transport Locks the transport assembly in place to allow for shipping the Autoloader. NOTE: The only way to unlock the transport after you run this test is to run the Unlock Transport test or power cycle the autoloader. [o] Unlock Transport Unlocks the transport assembly if you want to unlock the transport without power cycling the autoloader. The transport must have already been locked to use this test. [o] Back Magazine Removal Moves the transport so that you can access the back magazine for drive upgrades. [o] Test Transport Comm Exercises the internal infra-red communications path between the autoloader controller and the transport micro-controller. Reports the health of this link. If the test passes, the infra-red communication link is good. [o] Show All Sensors Dynamically displays the state of the door sensor. To toggle the door sensor, open and close the door. [o] Demonstration Selects a random full storage slot and moves the tape to the drive. The test locates a full slot, a full drive, an empty slot, and then performs an exchange. CAUTION: Run an inventory check from the host backup application after performing this test since the tapes will be in a different order. @ L9, diagnostic, test, inventory, recalibrate, wellness, transport, storedge, library, surestor Previously Published As 70512 Attachments This solution has no attachment |
||||||||||||
|