Steps to Follow
Create a Meta-network device:
1. Select network interface to be used.
2. Create meta-network and confirm uncommitted metadevice
domain# apnet -c -p qe0 -a qe4
domain# apconfig -N -u
3. Commit new metadevices to database and confirm committed metadevices.
domain# apdb -C
domain# apconfig -N
4. Setp hostname.xxx file
domain# mv /etc/hostname.qe0 /etc/hostname.mqe0
domain# rm /etc/hostname.qe4
5. Switch network traffic over to metanetwork.
(if you are logged in the network were you are making changes,
see next step below)
domain# ifconfig qe0 down
domain# ifconfig qe0 unplumb
domain# ifconfig qe4 down
domain# ifconfig qe4 unplumb
domain# ifconfig mqe0 plumb
domain# ifconfig mqe0 inet 136.162.65.30 up
6. If you are logged in via the network, ifconfig down will log you out.
You can either:
reboot domain, step 5 is then not needed
or
execute the commands in step five on one line separated by
semicolons(;), or put them into a script....
or login on another network interface and perform the actions in step 5
Switching Meta-network Paths
-P => meta network name
-a => new active path
domain# apconfig -P mqe0 -a qe4


Product
Sun Enterprise 10000 Server

Previously Published As
15058

Change History
Date: 2006-08-02
User Name: 71396
Action: Add Comment
Comment: *** This is an automatic message. This document has received 0 hits in Sunsolve in 60 days (see http://krep.emea.sun.com/stats/dochistory.cgi?docid=15058 ). If it does not receive any hit in the next 30 days, it will be automatically archived. See http://kmo.central.sun.com/VAM/ for further details. ***
Version: 0
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : Sandra McDougall
comment : Admin Cleanup - Audience fix, Tmark added,
Added Hardware - Enterprise 10000 and
AFO Vertical Team Docs - Hardware & Storage as
Categories, Spelling Corrections


date : Jun 26, 2002



updated by : Thom Chumley
comment : No comment
date : Jan 12, 1998
Version: 0
Product_uuid
29ddef46-0a18-11d6-92de-ae47474f0f6c|Sun Enterprise 10000 Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback