Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1005658.1 : Creating meta-network device on Ultra Enterprise[TM]10000 - Sun Enterprise 10000[TM]
PreviouslyPublishedAs 207849 Steps to Follow Create a Meta-network device: 1. Select network interface to be used. 2. Create meta-network and confirm uncommitted metadevice domain# apnet -c -p qe0 -a qe4 domain# apconfig -N -u 3. Commit new metadevices to database and confirm committed metadevices. domain# apdb -C domain# apconfig -N 4. Setp hostname.xxx file domain# mv /etc/hostname.qe0 /etc/hostname.mqe0 domain# rm /etc/hostname.qe4 5. Switch network traffic over to metanetwork. (if you are logged in the network were you are making changes, see next step below) domain# ifconfig qe0 down domain# ifconfig qe0 unplumb domain# ifconfig qe4 down domain# ifconfig qe4 unplumb domain# ifconfig mqe0 plumb domain# ifconfig mqe0 inet 136.162.65.30 up 6. If you are logged in via the network, ifconfig down will log you out. You can either: reboot domain, step 5 is then not needed or execute the commands in step five on one line separated by semicolons(;), or put them into a script.... or login on another network interface and perform the actions in step 5 Switching Meta-network Paths -P => meta network name -a => new active path domain# apconfig -P mqe0 -a qe4 Product Sun Enterprise 10000 Server Previously Published As 15058 Change History Date: 2006-08-02 User Name: 71396 Action: Add Comment Comment: *** This is an automatic message. This document has received 0 hits in Sunsolve in 60 days (see http://krep.emea.sun.com/stats/dochistory.cgi?docid=15058 ). If it does not receive any hit in the next 30 days, it will be automatically archived. See http://kmo.central.sun.com/VAM/ for further details. *** Version: 0 Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : Sandra McDougall comment : Admin Cleanup - Audience fix, Tmark added, Added Hardware - Enterprise 10000 and AFO Vertical Team Docs - Hardware & Storage as Categories, Spelling Corrections date : Jun 26, 2002 updated by : Thom Chumley comment : No comment date : Jan 12, 1998 Version: 0 Product_uuid 29ddef46-0a18-11d6-92de-ae47474f0f6c|Sun Enterprise 10000 Server Attachments This solution has no attachment |
||||||||||||
|