Solution Type Technical Instruction Sure Solution 1005617.1 : Validating Remote Replication Set Creation for a Sun StorEdge[TM] 6920
PreviouslyPublishedAs 207799 Description The purpose of this document is to provide basic steps for Remote Replication Set(repset) creation for the Sun StorEdge[TM] 6920 System, via the Browser User Interface(BUI) or sscs Command Line Interface(CLI). Content will be limited to a basic usage using the CLI or BUI interfaces for creating repsets, and provide help with some usage failure scenarios for this activity. Consider reviewing some of the following documents if you are looking to perform actions beyond the scope of this document:
NOTE: We consider basic replication set creation as the creation of a single set in synchronous mode. Steps to Follow Planning, Peer Links, Remote Volume, & Replication A. Start by Planning Remote Replication, is often the most complex of storage feature sets. It offers the ability to mirror data across a fibre channel or IP network. If you have not setup this capability before, you should read the Remote Replication section of the Best Practices for the Sun StorEdge 6920 System, Version 3.0.1. You should also review Sun StorEdge[TM] Data Replicator with Oracle Databases Usage Guide if you plan to replicate Database data(not necessarily just Oracle). The general contents apply to non-Oracle databases as well. Replication Requires the following components:
Again, the Best Practices for the Sun StorEdge 6920 System, Version 3.0.1 Chapter 6, has the best overall information for creating your own Remote Replication solution. Decisions to use specific configurations will not be discussed, here. If you have at least the components above, you are ready to create a SIMPLE replication set, and can continue to Step B. B. Setup Peer Links for the 6920 SSCS Configure Gigabit Ethernet Peer Link: sscs modify -r <enable|disable> -g <gateway_addr> -m <netmask> -l <local_6920> etherport <etherport> Example: sscs modify -r enable -g 192.168.0.1 -m 255.255.255.0 -l 192.168.0.100 etherport 3/7 Configure Fibre Channel Peer Link: sscs modify -r <enable|disable> fcport <fcport> Example: sscs modify -r enable fcport 1/6 BUI Configure Gigabit Ethernet Peer Link:
Configure Fibre Channel Peer Link:
C. Get the Remote Volume WWN This will require that you login to the Remote 6920 and get the volume WWN.
D. Get Remote 6920 Peer Replication WWN This can be gotten by listing out any Port details on the array, and getting SSCS sscs list fcport <fcportnumber> example: sscs list fcport 1/6 BUI
E. Create the Set on the Primary
SSCS
example: sscs create -l loc_vol -w 0123456789abcdef -b bitmap_pool -o 0123456789abcdef01234567789 -r primary -m sync -R low -p disable repset BUI
F. Get Primary Volume WWN Get the primary volume WWN on the local 6920. Reference <Document: 1009974.1> : Validating Volume State and Details on a Sun StorEdge[TM] 6920 G. Get the Primary 6920 Node WWN This can be gotten by listing out any Port details on the array, and getting SSCS sscs list fcport <fcportnumber> example: sscs list fcport 1/6 BUI
H. Create the Repset on the remote 6920 This will require that you login to the Remote 6920, reference <Document: 1012883.1> : Troubleshooting Sun StorEdge 6920[TM] Browser and sscs(1M) Access Problems The BUI and SSCS commands are identical with the following exceptions:
I. Start Full Forward Sync After creation, a full synchronization is required. This can be accomplished Full synchronizations can take a long time, and depends greatly on network latency and 6920 utilization. This can be shortened by employing the Fast Start option. Reference document:
Progress is provided as part of the Repset details. Reference <Document: 1005601.1> : Validating Sun Storedge[TM] 6920 Remote Replication details and state
J. Failure Notification
BUI
Action: Message: Action:
SSCS
Action: Message: Action: K. Data Collection Please collect the following information:
sscs list repset and contact Sun Support. NOTE: Screen captures of the summary page for each object could be used, as well, for BUI related creations. Product Sun StorageTek 6920 System Sun StorageTek 6920 Maintenance Update 2 Sun StorageTek 6920 Maintenance Update 1 Internal Comments Validate command and perfrom health check of array This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: [email protected]
The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK. Sun Support
Validate command provided against examples in the Sun StorEdge 6920 System CLI Quick Reference Guide, Release 3.0.
If the customer reports:
OR
Validate the services on the Service Processor. Reference <Document: 1007129.1>
Reference <Document: 1005447.1> : Sun StorEdge[TM] 6920 Health Checklist
Provide the following:
6920, replication, remote, mirror, create, sscs, browser, bui, normalized, Audited Previously Published As 90808 Change History Date: 2007-10-02 User Name: 97961 Action: Approved Comment: Publishing. No further edits required. Version: 6 Date: 2007-10-02 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2007-10-02 User Name: 39181 Action: Approved Comment: Reviewed section B, looks good. Sending to final review. Version: 0 Date: 2007-10-01 User Name: 88109 Action: Approved Comment: Please review Step B for content. Only thing modified. Version: 0 Date: 2007-10-01 User Name: 88109 Action: Update Started Comment: need to update for content in identical document Version: 0 Attachments This solution has no attachment |
||||||||||||
|