Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1005606.1 : Validating Mapping Deletion for Volumes and Initiators for a Sun StorEdge[TM] 6290
PreviouslyPublishedAs 207784 Description The purpose of this document is to provide basic steps for deleting LUN mapping for volumes and initiators for the 6920 array, via the Browser User Interface(BUI) or sscs Command Line Interface(CLI). Content will be limited to a basic usage using the CLI or BUI interfaces
Steps to Follow Validating Mapping Deletion for Volumes and Initiators for a Sun StorEdge[TM] 6290: A. Start By Planning
B. Stop Access to the device Unmapping volumes can cause a loss of access, resulting in application failure.
C. Un-Map Volume This allows you to un-map a single volume from many initiators. SSCS sscs unmap volume <volume name> example sscs unmap volume my-vol This will delete a volume-to-LUN mapping for the volume my-vol, on all initiators. BUI
D. Unmap Initiator to Volume This allows you to unmap a volume from a single initiator. SSCS sscs unmap -v <volume> initiator <initiator> example sscs unmap -v my-vol initiator my-init This will delete a volume-to-LUN mapping to the initiator my-init for the volume, my-vol. BUI
E. Validate Mapping Validate your mappings on the 6920. Reference document <Document: 1008480.1> Validating Mapping Status and Details on a Sun StorEdge[TM] 6920 Use the LUN ID and WWN of the Volume to validate your mappings on Solaris[TM]. Reference document <Document: 1009557.1> Troubleshooting Fibre Channel Devices from the Solaris[TM] OS F. Failure BUI Message: Action:
SSCS
Action: Message: Action: Message: Action: If a message is not listed or the actions did not work, go to Step G. G. Data Collection
sscs list volume and contact Sun Support Product Sun StorageTek 6920 System Sun StorageTek 6920 Maintenance Update 2 Sun StorageTek 6920 Maintenance Update 1 Internal Comments Sun Support This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: [email protected]
Validate command provided against examples in the Sun StorEdge 6920 System CLI Quick Reference Guide, Release 3.0.
If the customer reports:
OR
Validate the services on the Service Processor. Reference document <Document: 1007129.1>
Reference document <Document: 1005447.1> Sun StorEdge[TM] 6920 Health Checklist
Provide the following:
unmap, delete, mappings, map, 6920, volume, initiator, hba, normalized, Audited Previously Published As 90586 Change History Date: 2007-09-28 User Name: 7058 Action: Approved Comment: OK to publish. Version: 3 Date: 2007-09-26 User Name: 7058 Action: Accept Comment: Version: 0 Date: 2007-09-26 User Name: 70984 Action: Approved Comment: Reviewed and updated. Version: 0 Date: 2007-09-26 User Name: 70984 Action: Add Comment Comment: This document is "pending the completion of 89105, per normalization". Corrected line A. 1. to read: What is the volume you want to unmap? from: 1. What is the volume you want to map? Corrected line A. 2. to read: What is the initiator name you want to unmap? from 2. What is the initiator name you want to map? Corrected line D. to read: Unmap Initiator to Volume from D. Map Initiator to Volume Attachments This solution has no attachment |
||||||||||||
|