Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1005513.1
Update Date:2011-06-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1005513.1 :   How to Re-seat or Replace the Remote System Controller (RSC/SC) Card.  


Related Items
  • Sun Fire V480 Server
  •  
  • Sun Fire 280R Server
  •  
  • Sun Fire V880z Visualization Server
  •  
  • Sun Fire V890 Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire V490 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
207642


Description
This Document describes the general process to remove and install the Remote System Controller card. Also called the RSC or SC.



Steps to Follow
For more detailed info for your system type see docs listed below.
  1. Power off the system and remove power cords. This is needed due to the RSC card getting power as soon as the system is plugged in. Removing the card with the system plugged in could damage the card or cause personal injury.

  2. Locate the card and remove any cables connected to it. Be sure to label the cords for ease of reconnecting after work is complete.

  3. Remove the screw securing the card to the chassis back panel. Again be sure the is no power connected to the system. Also be sure to use proper antistatic precautions.

  4. Pull the card free from the slot. A slight rocking of the card my be needed to free it. Do not use excessive force to one end or one side of the card, this could damage the card.

  5. If re-seating the card then use the same card to install back into the system. If replacing the card then swap the new and old cards. Be sure to put the card on a antistatic mat.

  6. Align the card with the PCI slot, the opening for the card, and the card guide. Push the card into the slot. Apply even pressure along the edge of the card.

  7. Secure the RSC card faceplate to the back panel with the Phillips screw.

  8. Connect the cables that had been removed from the card.

  9. Connect the power cords to the system. (When this is done the card will receive power and start its own boot process)

  10. Connect to the card again via serial or telnet, (depends on how the card has been configured) to make sure it is working. (If connecting via telnet be sure to give the card enough time to boot)

  11. If the card was replaced run /usr/platform/`uname -i`/rsc/rscadm show if the configuration info is missing the card will need to be reconfigured.

For information specific to your system Please see the following links:

SunFire 280R: SunFire 280R Server Service Manual (See chapter 2. servicing the Main Logic Board and Components.)

SunFire V480: Sun Fire V480 Parts Installation and Removal Guide (See chapter 5. Servicing the PCI Riser Boards and related Components.)

SunFire V490: Sun Fire V490 Parts Installation and Removal Guide (See chapter 5. Servicing the PCI Riser Boards and related Components.)

SunFire V880: Sun Fire V880 Server Service Manual (See chapter 3. Servicing the Input/Output Board Side Components.)

SunFire V890: Sun Fire V890 Server Service Manual (See chapter 3. Servicing the Input/Output Board Side Components.)



Product
Sun Fire V890 Server
Sun Fire V880z Visualization Server
Sun Fire V880 Server
Sun Fire V490 Server
Sun Fire V480 Server
Sun Fire 280R Server

Internal Comments
Audited/updated 11/19/09 - [email protected], Entry Level SPARC Content Team Member

This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains.




To notify content
owners of a knowledge gap contained in this document, and/or prior
to updating this document, please contact the domain engineers that
are managing this document via the "Document Feedback" alias(es)
listed below:



Normalization Lead: Jim Robbins Domain Engineer/Lead : Josh
Freeman Document feedback alias : [email protected]


Normalize, RSC, replace
Previously Published As
91313

Change History
Date: 2011-06-02
User name: 108175
Action: Currency check
Comments: audited by D. Kojucharov, Entry-Level SPARC Content Lead
Date: 2008-11-24
User Name: T230884
Action: Quality Review
Date: 2007-12-14
User Name: 7058
Action: Approved
Comment: No WTS to verify doc type. Cannot vouch for correct doc type.
Title clear.
No tmarks needed.
Normalized keyword OK.
Links checked - OK.
Spell ck - OK
OK to publish.
Version: 4
Date: 2007-12-13
User Name: 7058
Action: Accept
Comment:
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback